3.
MAINTENANCE
IOM manual CTX centrifugal pumps
17
3.3.
Disassembly of the pump
The disassembly should be performed only by qualified personnel.
Each operation to be fulfilled with the machine must always be carried out once all the
electrical contacts have been disconnected. The pump-motor unit must be placed in a
position where it cannot be started unintentionally.
Before servicing in any way the parts that come in contact with the pumped liquid, make
sure that the pump has been fully emptied and washed. When draining the liquid, make
sure that there is no danger for people or the environment.
The numbers put in brackets, refer to the part numbers in the spare part drawings and spare
part lists in chapter
5.
“Spare parts”
.
3.3.1.
Disassembly procedure
Fig. 3.3.1
Unscrew the shaft guard screws [411] fastening
the shaft guards [41] to the lantern [11].
Fig. 3.3.2
Take off the shaft guards [41].
Fig. 3.3.3
Unscrew the casing mounting screws [141] and
remove them with the nuts [143] and washers
[142].
Fig. 3.3.4
Take off the pump casing [13].
411
4
41
2
141
142
16
14
1
Содержание CTX I