background image

 

1. 

INSTALLATION

 

 

IOM manual CTV vertical centrifugal pumps

 

10

  

 

1.10.

 

Instruments 

 

In order to ensure a proper control of the performance and the conditions of the installed 
pump, we recommend using the following instruments: 

 

a pressure gauge on the discharge piping. 

 
The pressure gauge on discharge must always be fitted between the pump and the shut-off 
regulation valve. The output can be read on the pressure gauge, transformed into meters 
and then compared with the typical curves. 
 

1.10.1.

 

Electric power

 

 

The electric power absorbed by the motor can be measured by means of a wattmeter. 

 

1.10.2.

 

Optional instruments

 

 

The optional instruments can indicate if pump is working in an abnormal way. The abnormal 
conditions can be caused by: accidentally closed valves, lack of pumped liquid, overloads, 
etc. 

 

1.10.3.

 

Thermometer

 

 

If the temperature of the pumped liquid is a critical parameter, provide the installation with 
a thermometer (preferably on the suction side). 

 

1.11.

 

Motor connection 

 

 
 

An electrician must always carry out the electrical connection. Compare the power supply 
with  the  data  plate  specifications  and  then  choose  a  suitable  connection.  The  type  of 
connection is stated on the motor data plate and can be Y (star) or D (Delta), according to 
the power supply of the motor (see figure below). 

STAR 

DELTA 

 

 

 

 

Follow the connection standard used in the plant. In no case connect the electrical motor 
directly  to  supply  network  but  use  a  suitable  electric  switchboard  equipped  with  a  knife 
switch and suitable safety devices (e.g. motor breaker switches) in the power circuit. Safety 
devices  against  overloads  must  also  protect  the  motors.  Make  sure  that  the  motor  has 
suitable grounding and that it has been connected properly. 

Содержание CTV Series

Страница 1: ...CTV25 10 CTV25 9 8 CTV25 11 CTV40 12 5 CTV25 11 5 CTV40 13 5 CTV32 8 5 CTV32 10 CTV32 12 5 CTV Vertical Centrifugal Pumps Original Instruction 2020 1 Read this instruction manual carefully before you...

Страница 2: ...ping 7 1 7 1 Connection of discharge pipe 7 1 7 2 Connection of suction pipe 7 1 8 Health and safety 8 1 8 1 Protection 8 1 8 2 Electrical safety 8 1 8 3 Chemical hazard 8 1 8 4 Noise level 8 1 8 5 Te...

Страница 3: ...inless steel pumps 21 3 3 5 Assembly of the pump 23 3 3 6 Test run 24 4 OPTIONS 25 4 1 Suction extension and strainer 4E05 4E10 4S 25 4 2 Optional discharge connection 5A 5D 25 4 3 Left hand thread on...

Страница 4: ...relevant Union harmonization legislation Directive 2006 42 EC of European Parliament and of the Council of 17 May 2006 on machinery amending Directive 95 16 EC Directive 2014 35 UE of the European Pa...

Страница 5: ...l safety instructions in this instruction manual where danger to life and limb may occur Observe these instructions and proceed with utmost caution in these situations Inform also other users of all s...

Страница 6: ...receipt Make sure that all parts and accessories listed on the packing list are accounted for Immediately report any damage or shortage to the transport company and to us 1 3 Storage If the equipment...

Страница 7: ...of the components has a great influence on the operation and the lifetime of the pump The pump cannot be used as a support for the components connected to it The flow of liquid from the pump must be a...

Страница 8: ...1 8 4 Noise level CTV pumps including the motor in normal operating conditions produce a sound level below 80 dB A The major sources of noise are liquid turbulence in the installation cavitation or a...

Страница 9: ...ank sump installation Installations with suction extension 8 Vertical suction extension is allowed Size of pipe shall correspond with pump connection size Do not use complex piping on suction side In...

Страница 10: ...es lack of pumped liquid overloads etc 1 10 3 Thermometer If the temperature of the pumped liquid is a critical parameter provide the installation with a thermometer preferably on the suction side 1 1...

Страница 11: ...nal Mounting Arrangement V1 Number of poles Rotation speed rpm 2 Non ATEX Protection grade IP55 Voltage 3 phase Motor power RPM Voltage Frequency 0 55 kW 2800 230 400 50 Hz 3400 265 460 60 Hz 0 75 kW...

Страница 12: ...discharge shut off regulation valve gradually until the desired output has been reached The pump must not run two or three minutes with closed discharge Longer operation in these conditions can serio...

Страница 13: ...fore the pump has to thoroughly cleaned before disposal 2 5 Waste of electrical and electronic equipment WEEE directive Users of electrical and electronic equipment EEE with the WEEE marking per Annex...

Страница 14: ...o low See MIN start level chapter 1 7 Example of installation X X Motor speed too low Check the motor and motor connection X X X X Impeller is clogged Clean the pump X X X X Impeller is damaged Replac...

Страница 15: ...t the pump has been fully emptied and washed When draining the liquid make sure that there is no danger for people or the environment The numbers put in brackets refer to the part numbers in the spare...

Страница 16: ...ve the motor fan Fig 3 3 1 5 Secure the free end of the motor shaft using universal pliers or similar Fig 3 3 1 6 Unscrew the impeller Fig 3 3 1 7 Remove the impeller O ring 193 from the impeller Fig...

Страница 17: ...rom the discharge pipe 12 The pump is now completely disassembled Check all components especially the O rings and lip seal for wear or damage and replace if necessary The casing O ring should be repla...

Страница 18: ...e O ring 193 into the impeller 9 Fig 3 3 2 5 Insert the shaft sleeve 162 into the pump casing unit 11 Fig 3 3 2 6 While holding the shaft sleeve 162 rotate the pump casing unit 11 Fig 3 3 2 7 Apply so...

Страница 19: ...n in order to perform this procedure Use a torque wrench to screw the impeller with the appropriate torque see table in section 6 2 Fig 3 3 2 10 Proper utilization of the 8 32 9XXX MT assembly tool Fi...

Страница 20: ...13 Screw the plug 22 onto the pump casing unit 11 Note Use PTFE tape on the thread Fig 3 3 2 14 Screw the elbow 17 into the pump casing unit 11 Note Use PTFE tape on the thread Fig 3 3 2 15 Screw the...

Страница 21: ...pump casing unit 11 Note Use some alcohol grease to ease the assembly of the pump cover 3 3 3 Test run We recommend you to conduct a test run of the pump before installing it in the system so no liqui...

Страница 22: ...ays replace the casing O ring after pump maintenance Fig 3 3 4 5 Secure the impeller unscrew the impeller nut 191 and washer 192 lift off the impeller 9 NOTE If the impeller is hard to unscrew take of...

Страница 23: ...ally the O ring and lip seal for wear or damage and replace if necessary The casing O ring should be replaced after every pump disassembly 3 3 5 Assembly of the pump The assembly procedure is done in...

Страница 24: ...ghten the connections between the pump cover 13 elbow 17 and discharge pipe 12 3 3 6 Test run We recommend you to conduct a test run of the pump before installing it in the system so no liquid gets wa...

Страница 25: ...n to the piping A suction strainer is also a possible option where the liquid is dirty or contains solids Additional parts Art no Q ty Description 7 xx 145 1 Suction extension pipe for SS pump 500 mm...

Страница 26: ...th a cut on the socket This way unscrewing of pump cover is avoided This option is recommended especially when viscous liquids are pumped The pump cover code is 8 xx 1312L 4 4 Motor mounting screw pro...

Страница 27: ...her 4 A4 70 123 Motor mounting spring washer 4 A4 80 1312 Pump cover 1 PP PVDF 15 Shaft bushing with O ring 1 Ceramic NBR 151 Shaft bushing O ring 1 NBR 161 Lip seal 1 NBR FKM 162 Shaft sleeve 1 PP PV...

Страница 28: ...mounting spring washer 4 A4 80 13 Pump cover 1 AISI 316L 141 Casing mounting screw 4 A4 70 142 Casing mounting washer 4 A4 80 143 Casing mounting nut 4 A4 70 15 Shaft bushing 1 PTFE 161 Lip seal 1 NBR...

Страница 29: ...parts in stock PP PVDF pumps Pos Description Q ty 161 Lip seal 1 193 Impeller O ring 1 18 Casing O ring 1 15 Shaft bushing 1 151 Shaft bushing O ring 1 Stainless steel pumps Pos Description Q ty 161...

Страница 30: ...pipe 500 mm strainer S Pump with strainer 5 Optional discharge connection 1st letter connection standard Blank BSP plastic pumps BSPT metal pumps thread A ANSI flange D DIN flange 2nd letter material...

Страница 31: ...0 98 K 413 16 26 L 123 126 4 84 4 96 M 60 2 36 N BSP 1 1 1 1 Dimension may vary depending on motor brand Pump model CTV 25 9 25 10 25 11 25 11 5 32 8 5 32 10 32 12 5 Max capacity m3 h 12 14 15 5 18 13...

Страница 32: ...H BSPT 1 1 1 1 I 0 55 kW 275 5 10 85 0 75 kW 2 2 kW 299 11 77 J 8 0 31 K 420 5 414 425 16 56 16 30 16 73 L 113 5 127 193 4 47 5 00 7 60 M 60 66 65 2 36 2 60 2 56 N BSPT 1 1 1 1 Dimension may vary dep...

Страница 33: ...ATA IOM manual CTV vertical centrifugal pumps 33 6 4 Performance curves The performance curves are based on water at 0 C Speed 2900 rpm Contact us for detailed curves PP PVDF pumps Stainless steel pum...

Страница 34: ...t of force inlet outlet Nm X 23 4 Y 23 4 Z 23 4 CTP 32 PP PVDF Direction Load N inlet outlet Moment of force inlet outlet Nm X 33 6 Y 33 6 Z 33 6 CTV 20 SS Direction Load N inlet outlet Moment of forc...

Страница 35: ...the Customer except for those purposes set out in any invitation to render documents or other documents specifically made available to Tapflo before entering into this agreement c high quality materi...

Страница 36: ...parts or components will become the property of Tapflo 7 The products are built in accordance with standard CE normative and are tested where applicable by Tapflo Approval and tests by other control...

Страница 37: ...elivery Date Date of pump installation Pump type Serial No see name plate Description of the fault The installation Liquid Temperature C Viscosity cPs Spec grav kg m3 pH value Content of particles of...

Страница 38: ......

Отзывы: