3.  PRODUCT DESCRIPTION 

 

3.1  Sensing edge Shapes and Sizes 

Tapeswitch edge sensors are available in a large range of profiles colors and lengths to accommodate most 
common applications. See specifications for profile (section 9) dimensions, maximum length and force travel 
relationship.  
  

3.2  Inactive Zone 

All standard safety edge sensors have an inactive region at each edge. Please see specific edge sensor profile 
for actual inactive diminution in the specification’s sections (9) of this manual.

 

 

3.3  Lead Options 

 

Tapeswitch Edge sensors have a number of lead options, depending on the application. Cable exit options are 
also available, so as to facilitate a “daisy chain” connection (or series connection) between them. Please see 

www.Tapeswitch.com

 or contact Tapeswitch directly if needed. 

 

 

 

All Lead Configuration Options - Figure 2 

 
 

3.4  Mounting Channel Options 

 

Most edge sensors are available with multiple options of mounting channels and channel materials based on 
design application. See individual edge specification at 

www.tapeswitch.com

 (section 9 in this document) as to 

the options available.  
 

                                                              NOTE: 

It is the responsibility of the user to evaluate and determine the proper edge sensor profile and dimensions based 
on  the  application  in  question.

  Tapeswitch  cannot  guarantee  suitability  of  a  particular  edge,  for  a  machine  or 

application with unique specifications that was not designed by Tapeswitch. The unique parameters of the control 
system into which the sensing edge(s) are integrated must be validated by the user. Tapeswitch also takes over 
no liability for recommendations which are given or implied in the following description. The following description 
implies no modification of the general Tapeswitch terms of delivery, warranty or liability claims.

 

 

Содержание Safety Edge TS-16

Страница 1: ...ust ensure that all persons involved in the installation commissioning operation maintenance and servicing of the product have access to all the information supplied by the manufacturers of the machin...

Страница 2: ...4 2 3 Combining of Sensors 6 4 2 3 1 Four wire edge sensors fail safe 7 4 2 3 2 Two wire edge sensors with end of line EOL resistor 8 5 EDGE SENSOR SELECTION 5 1 General Considerations 9 5 2 Edge Sens...

Страница 3: ...p command to the prime motion and should not attempt to begin running until the fault condition is fully accessed repaired and tested thus the machine cannot run unless there is integrity throughout t...

Страница 4: ...T ROLL COIL OR FOLD THEM DO NOT LIFT OR PULL edge sensor s BY THE CABLES Failure to follow these instructions could render the edge sensors unusable 2 2 Transportation When shipping an edge or edges u...

Страница 5: ...nnection between them Please see www Tapeswitch com or contact Tapeswitch directly if needed All Lead Configuration Options Figure 2 3 4 Mounting Channel Options Most edge sensors are available with m...

Страница 6: ...d 4 2 2 Chemical Resistance Tapeswitch safety edge sensors are constructed utilizing several material compounds All materials are resistant to chemicals commonly found in an industrial environment Ple...

Страница 7: ...one pair of leads can be considered to be the input and the other pair the output When connecting several edge sensors together the output of the first edge sensor is connected to the input of the sec...

Страница 8: ...nterfaced to the machine control system as intended For applications that require an array of interconnected sensing edges and an end of line EOL resistor all edge sensor segments but the last must be...

Страница 9: ...motion in a control reliable method according to determined SIL NOTE The guidelines described in this document must only be carried out by qualified personnel Such personnel must have the appropriate...

Страница 10: ...ically affixed such that it cannot be easily moved or removed Tamperproof hardware is highly recommended to discourage any un authorized manipulation of the edge sensor or sensors g There are no user...

Страница 11: ...d can be addressed through Tapeswitch at sales tapeswitch com 6 2 2 Mounting guidelines EDGE INSTALLATION PROCEDURE Edge series configurations and single edge assemblies may be shipped mostly assemble...

Страница 12: ...d Position channels onto pre determined machine location Transfer drill if needed Secure with flat or pan head screws See chart below Recommended fasteners for Edge mounting channels Figure 7 FLAT CH...

Страница 13: ...housing and actuator should at no point be removed from the channel unless a replacement is required Mounting holes 1 4 20 or similar should be drilled roughly every 12 of sensor length for sufficien...

Страница 14: ...the sensor to the channel without additional room needed on each end of the channel Before attempting to snap the housing and actuator into the channel apply lubricant mild soapy water to housing cha...

Страница 15: ...or non fail safe sensor options Non fail safe edges can NOT be made FAIL SAFE For applications where multiple edge sensors are required the EE lead exits each end ordering code must be specified This...

Страница 16: ...e The figures below illustrate two controllers which are suitable for the aforementioned wiring configurations PRSU 4 Schematic Connection Figure 14 See PRSU 4 manual for complete connection details h...

Страница 17: ...utilizing PSSR 2 controller all edges other than the final edge with EOL resistor termination will be called out as standard four wire edges PSSR 2 connection Figure 16 PSSR 2 schematic connection Fi...

Страница 18: ...ed from damage during normal use and meets all local electrical codes 7 COMMISSIONING CHECKS The commissioning checks should be carried out by trained competent personnel who have access to all the in...

Страница 19: ...is indicating correctly l Test the muting arrangements if installed Ensure that the muting is only possible during non dangerous operation and ensure that the safety level of the muting device is at o...

Страница 20: ...tch for actuation Ribbon switch devices consisting of a pair of metal conductor plates with an extruded jacket of soft PVC 3 Lead Wires Tapeswitch edge sensors are available with several options regar...

Страница 21: ...1753 2020 Tapeswitch Corporation All Rights Reserved 21 conductor or one 4 conductor cables each comprised of 4 separate color coded PVC insulated conductors Conductors will be comprised on 24 AWG or...

Страница 22: ...2020 Ver 1 0 Installation Manual Safety Edge TAPESWITCH CORPORATION 100 Schmitt Boulevard Farmingdale New York 11753 2020 Tapeswitch Corporation All Rights Reserved 22 TS 8 activation characteristics...

Страница 23: ...2020 Ver 1 0 Installation Manual Safety Edge TAPESWITCH CORPORATION 100 Schmitt Boulevard Farmingdale New York 11753 2020 Tapeswitch Corporation All Rights Reserved 23 TS 18 activation characteristics...

Страница 24: ...Ver 1 0 Installation Manual Safety Edge TAPESWITCH CORPORATION 100 Schmitt Boulevard Farmingdale New York 11753 2020 Tapeswitch Corporation All Rights Reserved 24 TS 46 and TS 47 activation characteri...

Страница 25: ...Ver 1 0 Installation Manual Safety Edge TAPESWITCH CORPORATION 100 Schmitt Boulevard Farmingdale New York 11753 2020 Tapeswitch Corporation All Rights Reserved 25 TS 48 and TS 57activation characteri...

Страница 26: ...2020 Ver 1 0 Installation Manual Safety Edge TAPESWITCH CORPORATION 100 Schmitt Boulevard Farmingdale New York 11753 2020 Tapeswitch Corporation All Rights Reserved 26 TS 67 activation characteristics...

Страница 27: ...Release 08 2020 Ver 1 0 Installation Manual Safety Edge TAPESWITCH CORPORATION 100 Schmitt Boulevard Farmingdale New York 11753 2020 Tapeswitch Corporation All Rights Reserved 27...

Страница 28: ...istance measurements are within stated limits Pairs to Test Edge State Proper Measured Result Black to Black or Ribbed to Ribbed Not actuated Less than 5 ohms White to White or Smooth to Smooth Not ac...

Страница 29: ...ircuit Yellow and White Actuated Less than 5 ohms Continuity table for edge sensors with single 4 conuctor lead characteristics Figure 26 Any measurement beyond the limits specified under Proper Measu...

Страница 30: ..._______ ______________________________________________________________________________ ______________________________________________________________________________ __________________________________...