background image

P

ART

 N

UMBER

 1260600601 R

EV

B

Installation and 

Maintenance 

Manual

Alpha Premier Information Display

Содержание Adaptive Alpha Premier

Страница 1: ...PART NUMBER 1260600601 REV B Installation and Maintenance Manual Alpha Premier Information Display...

Страница 2: ...ays com Adaptive is a registered trademark of Adaptive Display Systems Alpha Premier Information Display is a registered trade mark of Adaptive Display Systems All other brand and product names are tr...

Страница 3: ...tion 4 1 Earth grounding signs 4 2 Lightning strike protection 4 2 Install power to the sign 4 3 Connect to the messaging computer 5 1 Physical inspection 6 1 Front lens cleaning outside of sign 6 2 T...

Страница 4: ...THIS PAGE INTENTIONALLY BLANK 2 ALPHA PID SIGN INSTALLATION AND MAINTENANCE MANUAL PN 1260600601 REV B...

Страница 5: ...nnect an Alpha PID sign It is intended for sign installers Revision history Safety information Equipment symbols Dangers warnings cautions and notices Dangers Warnings cautions and notices are posted...

Страница 6: ...of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Memory backup In the event of po...

Страница 7: ...similar Item Name Description A POWER ENTRY Entry point for power wiring B COMMUNICATION ENTRY Entry point for communication cables C TAMPER PROOF DOOR LATCH Water tight latch covers keyhole D LIGHT...

Страница 8: ...are similar Item Name Description A POWER ENTRY Entry point for power wiring B COMMUNICATION ENTRY Entry point for communication cables C TAMPER PROOF DOOR LATCH Water tight latch covers keyhole D LIG...

Страница 9: ...y open the sign 2 Use the latch key to open all but one of the door latches on the front of the sign DANGER Hazardous voltage Contact with high voltage will cause death or serious injury The power swi...

Страница 10: ...t of the sign case to control the force at which at sign opens 4 Lower the display board rail Locate the screws securing the inner display board panel Use a 2 Phillips screwdriver to loosen the captiv...

Страница 11: ...B 5 VDC POWER SUPPLY Supplies power to the controller display adapter and fans C POWER RAIL Contains the circuit breaker customer AC connections 5VDC power supply and surge suppressor D 4 2VDC POWER...

Страница 12: ...m Name Description A 4 2 VDC POWER SUPPLY Supplies power to the display boards B CIRCULATING FAN Circulates air within the sign to cool the components C LIGHT SENSOR Monitors ambient light and adjusts...

Страница 13: ...the sign C SERIES LETTER Revision level of sign D ELECTRICAL INFORMATION Input voltage frequency and total amperage of the sign AMPS total sign amperage Adaptive Micro Systems LLC 7840 N 86th Street M...

Страница 14: ...ounted Super structures must be approved by a qualified structural engineer ID sign Company name and or logo sign supplied by the customer or installer ID signs used in conjunction with Adaptive signs...

Страница 15: ...r structure Sign installers must comply with the following Adaptive requirements or the sign warranty will be void Any ID sign fascia trim or structure used above the sign must either have flashing or...

Страница 16: ...ty Signs require obstruction free space for adequate air ventilation between solid mounting surfaces and the top bottom and sides of the sign Always take into consideration other neighboring heat sour...

Страница 17: ...ht of the sign Support the sign evenly across the bottom using equipment supplied by others Move the sign into place before mounting Then use optionally supplied mounting kits to mount the sign Take c...

Страница 18: ...to avoid galvanic corrosion Any area on the sign s frame from which paint is removed during mounting must be recoated with paint that is UL recognized to standard UL 1332 category DTOV2 Failure to re...

Страница 19: ...MOUNTING THE SIGN 3 Bracket ceiling mounting optional Tools you will need 7 16 inch socket or wrench Install the brackets using the provided hardware as shown below Wall mounting Tools you will need 7...

Страница 20: ...ANCE MANUAL PN 1260600601 REV B 3 7 Mechanical Installation 3 INSTALL THE SUN SHIELD OPTIONAL Install the sun shield optional Tools you will need 7 16 inch socket or wrench Install the sun shield usin...

Страница 21: ...THIS PAGE INTENTIONALLY BLANK 3 8 ALPHA PID SIGN INSTALLATION AND MAINTENANCE MANUAL PN 1260600601 REV B...

Страница 22: ...ndard configuration is 120VAC The sign may be configured as 240VAC as a custom order The sign must be run on it s own dedicated circuit to ensure proper operation This is particularly important when t...

Страница 23: ...effective ground Adaptive also recommends the following guidelines Use copper clad ground rods as the grounding electrode They provide effective grounding for an indefinite period of time Depending o...

Страница 24: ...to the sign using weather tight conduit 2 Connect each power circuit to the appropriate wireway power terminal on the power plate 3 Connect a minimum of one grounding lug to an earth ground rod 4 Pla...

Страница 25: ...THIS PAGE INTENTIONALLY BLANK 4 4 ALPHA PID SIGN INSTALLATION AND MAINTENANCE MANUAL PN 1260600601 REV B...

Страница 26: ...gn must be connected to a computer that is running AlphaNET software or other software compatible with the player installed on the controller This computer is referred to as the messaging computer The...

Страница 27: ...THIS PAGE INTENTIONALLY BLANK 5 2 ALPHA PID SIGN INSTALLATION AND MAINTENANCE MANUAL PN 1260600601 REV B...

Страница 28: ...k for any physical damage to the interior of the sign Check for loose nuts bolts hinges doors and so on Check the interior electronics for foreign debris and general cleanliness Check the interior of...

Страница 29: ...Do not use solvents Use of solvents will damage the lens UV stabilizer Soft cloth or soft paper towels Cleaning procedure 1 Spray the glass cleaner onto the front lens of the sign Notice Do not clean...

Страница 30: ...ION AND MAINTENANCE MANUAL PN 1260600601 REV B 6 3 Maintenance 6 TURN OFF POWER Turn off power 1 Open the sign 2 Locate the circuit breaker There is one circuit breaker in the sign Position the switch...

Страница 31: ...ions see Turn off power on page 6 3 2 Loosen the two screws on the circuit breaker Disconnect the wires 3 Pull the circuit breaker toward you and lightly twist it to pop it off of the rail Install the...

Страница 32: ...suppressor There is only one surge suppressor It is located in the primary sign 3 Loose the two screws on the surge suppressor Disconnect the wires 4 Pull the surge suppressor toward you and lightly...

Страница 33: ...r instructions see Turn off power on page 6 3 2 Locate the device There is only one Ethernet device It is located in the primary sign 3 Disconnect the connections 4 Remove the device Install the repla...

Страница 34: ...ons see Turn off power on page 6 3 2 Locate the device There is only one Ethernet to fiber optic converter It is located in the primary sign 3 Disconnect the cables 4 Remove the device Install the rep...

Страница 35: ...e device For two sided signs th ere is a light sensor on each side of the sign 3 Remove the two screws 4 Open the display board rail to expose the back side of the components Locate the light sensor 5...

Страница 36: ...For instructions see Turn off power on page 6 3 2 Locate the power supply Two sided signs contain power supplies in each side of the sign 3 Disconnect the cables and remove the nuts 4 Slide the plate...

Страница 37: ...5VDC power supply It is located in the primary sign 3 Use your finger or a small screw driver to press the tab to release the power supply from the rail 4 Pull the power supply toward you and lightly...

Страница 38: ...he six mounting screws Notice Carefully and slowly disconnect the cables Connector pins can bend and break if forced Install the replacement display adapter 1 Align the holes on the display adapter wi...

Страница 39: ...t all cables from the display adapter and remove the 6 mounting screws Notice Carefully and slowly disconnect the cables Connector pins can bend and break if forced Install the replacement sign contro...

Страница 40: ...Remove the nuts that secure the fan bracket to the sign enclosure 4 Remove the screws that secure the fan to the bracket Disconnect the wires Install the replacement fan 1 Insert the replacement fan...

Страница 41: ...Remove the six screws and disconnect the cables Notice Carefully and slowly disconnect the cables Connector pins can bend and break if forced 4 Remove the display board from the sign Install the repl...

Страница 42: ...THIS PAGE INTENTIONALLY BLANK...

Страница 43: ...PART NUMBER 1260600601 REV B Adaptive Display Systems 7840 North 86th Street Milwaukee WI 53224 USA 414 357 2020 www AdaptiveDisplays com...

Отзывы: