background image

©2000 Tanita Corporation  3/00 HDI

TANITA Europe GmbH

Dresdener Strasse 25 
D-71065 Sindelfingen, Germany
Tel: 07031-6189-6
Fax: 07031-6189-71

TANITA UK Ltd.

The Barn, Philpots Close, Yiewsley, 
West Drayton, Middlesex, UB7 7RY, UK
Tel: 01895-438577
Fax: 01895-438511

TANITA France S.A.

Villa Labrouste
68 Boulevard Bourdon
92200 Neuilly-Sur Seine
Tel: 01 55 24 99 99  Fax: 01 55 24 98 68

TANITA Health Equipment H.K. Ltd.

Unit 301-303 3/F Wing On Plaza
62 Mody Road, Tsimshatsui East
Kowloon, Hong Kong
Tel: 852-2838-7111  Fax: 852-2838-8667

TANITA Corporation of Japan

14-2, 1-Chome, Maeno-Cho
Itabashi-Ku, Tokyo, Japan 174-8630
Tel: 03-3968-2123
Fax: 03-3967-3766
www.tanita.co.jp
ISO 9001 Certified

TANITA Corporation of America Inc.

2625 South Clearbrook Drive
Arlington Heights, IL 60005 USA
Tel: 847-640-9241 Fax: 847-640-9261
Toll Free: 1-800-TANITA-8 
e-mail: [email protected]
www.tanita.com

Содержание BF-623

Страница 1: ...BF 623BODYFAT MONITOR SCALE Instruction Manual Read this Instruction Manual carefully and keep it for future reference ...

Страница 2: ...protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interferenc...

Страница 3: ...at least 10 hours per week and who has a resting heart rate of approximately 60 beats per minute or less Tanita s athlete definition includes lifetime of fitness individuals who have been fit for years but currently exercise less than 10 hours per week Tanita s athlete definition does not include enthusiastic beginners who are making a real commitment to exercising at least 10 hours per week but w...

Страница 4: ...e So the amount of fat in the body can be accurately estimated by measuring the impedance The signal used is very low making it safe and imperceptible The illustration on the left show how the signal travels through the body Body Fat Percentage Fluctuations in a Day Hydration levels in the body may affect body fat readings Readings are usually highest in the early waking hours since the body tends...

Страница 5: ...ation studies to predict body composition Readings taken with Tanita s BF 623 correlate highly with both DEXA Tanita s reference model and Hydrodensitometry Features and Functions Components Measuring Platform Warranty Support Feet 4 Educational Booklet AA Size Batteries 4 Getting Started Workbook Instruction Manual Measuring Platform 1 Display Screen 2 Orange Set Button 3 Green Arrow Select Butto...

Страница 6: ...a mistake during measurement or a key or button operation After you have completed the measuring process Note If the power shuts off unexpectedly repeat the measuring process Preparations Before Use Inserting the Batteries 1 Locate the battery cover on the back of the measuring platform Press the tab to release the cover as shown 2 Insert the supplied AA size batteries as indicated Note Be sure th...

Страница 7: ...8 or older Child up to the age of 18 over 3 ft 4 in 102 cm 4 Select Male or Female Use the Green Arrow button to select Male or Female then press the Orange Set button Male Female 5 Specify the Height Use the Green Arrow button to specify Height in feet and inches Then press the Orange Set button The display will flash all data Adult Child Male Female and Height for three seconds to confirm the pr...

Страница 8: ... body fat percentage and body weight will be displayed alternately at two second intervals If you remain on the platform the display will continue for about 30 seconds and then the power will automatically turn off If you step off the platform the alternating display of body fat percentage and body weight will be repeated three times and then the power will automatically turn off Multiple Users Th...

Страница 9: ...ntage reading does not appear after the weight is measured Vibration will interfere with the fat percentage reading Be sure to stand erect and still on the measuring platform Do not bend your knees Be sure that shoes and socks are removed and check foot alignment Step off and repeat steps on p 6 The body fat percentage reading is extremely low Be sure you have selected the correct user mode Adult ...

Страница 10: ...n is authorized to change the terms of this warranty If Product Is Defective or Needs Repair Do not return this product to the place of purchase doing so may delay the processing of your warranty claim Call Tanita at1 800 TANITA 8 to receive a Return Authorization Number before returning this product Include 12 50 for handling return postage and insurance to the facility listed below Proof of purc...

Страница 11: ... Tel 01 55 24 99 99 Fax 01 55 24 98 68 TANITA Health Equipment H K Ltd Unit 301 303 3 F Wing On Plaza 62 Mody Road Tsimshatsui East Kowloon Hong Kong Tel 852 2838 7111 Fax 852 2838 8667 TANITA Corporation of Japan 14 2 1 Chome Maeno Cho Itabashi Ku Tokyo Japan 174 8630 Tel 03 3968 2123 Fax 03 3967 3766 www tanita co jp ISO 9001 Certified TANITA Corporation of America Inc 2625 South Clearbrook Driv...

Отзывы: