Chapter 2 – Important Safety Information
CONFIRM
that the screen display
turns on, you can hear audible beeps,
feel the pump vibrate, and see the
green LED light blinking around the
edge of the Screen On Button when
you connect a power source to the
USB port. These features are used to
notify you about alerts, alarms, and
other conditions that require your atten-
tion. If these features are not working,
discontinue use of the pump and con-
tact Tandem Diabetes Care Customer
Technical Support at (877) 801-6901.
CHECK
your pump regularly for poten-
tial alarm conditions that may display.
It is important to be aware of condi-
tions that may affect insulin delivery
and require your attention so you can
respond as soon as possible.
DO NOT
use the vibrate feature for
alerts and alarms during sleep unless
otherwise directed by your healthcare
provider. Having the volume for alerts
and alarms set to high will help ensure
that you don’t miss an alert or alarm.
ALWAYS
look at the screen to confirm
correct programming of the bolus
amount when you first use the Quick
Bolus feature. Looking at the screen
will ensure that you are correctly using
the beep/vibration commands to pro-
gram the intended bolus amount.
DO NOT
use your pump if you think
it might be damaged due to dropping
it or hitting it against a hard surface.
Check that the pump is working
properly by plugging a power source
into the USB port and confirming that
the display turns on, you hear audible
beeps, feel the pump vibrate, and see
the green LED light blinking around the
edge of the Screen On Button. If you
are unsure about potential damage,
discontinue use of the pump and con-
tact Tandem Diabetes Care Customer
Technical Support at (877) 801-6901.
AVOID
exposure of your pump to
temperatures below 40°F (5°C) or
above 99°F (37°C). Insulin can freeze
at low temperatures or degrade at high
temperatures. Insulin that has been
exposed to conditions outside of the
manufacturer’s recommended ranges
can affect the safety and performance
of the pump.
AVOID
submersing your pump in fluid
beyond a depth of 3 feet or for more
than 30 minutes (IPX7 rating). If your
pump has been exposed to fluid be-
yond these limits, check for any signs
of fluid ingress. If there are signs of
fluid entry, discontinue use of the pump
and contact Tandem Diabetes Care
Customer Technical Support at (877)
801-6901.
AVOID
areas where there may be
flammable anesthetics or explosive
gases. The Pump is not suitable for
use in these areas and there is a risk of
explosion. Remove your pump if you
need to enter these areas.
MAKE SURE
to not move further than
the length of the USB cable when
you are connected to the pump and
to a charging source. Moving further
than the length of the USB cable may
cause the cannula to be pulled out of
the infusion site. For this reason it is
recommended not to charge the pump
while sleeping.
DISCONNECT
your infusion set from
your body while on high-speed/high
gravity amusement park thrill rides.
Содержание t:slim X2
Страница 2: ......
Страница 14: ...Section 1 Before You Begin...
Страница 15: ...Chapter 1 Introduction...
Страница 19: ...Chapter 2 Important Safety Information...
Страница 31: ...Chapter 3 Getting to Know Your t slim X2 Pump...
Страница 54: ...Section 2 Key Pump Features...
Страница 55: ...Chapter 4 Getting Started...
Страница 60: ...Customer Technical Support 877 801 6901 60 Chapter 4 Getting Started THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 61: ...Chapter 5 Infusion Site Care and Loading Cartridge...
Страница 75: ...Chapter 6 Personal Profiles...
Страница 84: ...Customer Technical Support 877 801 6901 84 Chapter 6 Personal Profiles THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 85: ...Chapter 7 Bolus...
Страница 92: ...Customer Technical Support 877 801 6901 92 Chapter 7 Bolus THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 93: ...Chapter 8 Stop Resume Insulin...
Страница 96: ...Section 3 Additional Pump Operations...
Страница 97: ...Chapter 9 Temporary Basal Rate...
Страница 100: ...Customer Technical Support 877 801 6901 100 Chapter 9 Temporary Basal Rate THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 101: ...Chapter 10 Quick Bolus...
Страница 104: ...Customer Technical Support 877 801 6901 104 Chapter 10 Quick Bolus THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 105: ...Chapter 11 t slim X2 Pump Settings...
Страница 108: ...Customer Technical Support 877 801 6901 108 Chapter 11 t slim X2 Pump Settings THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 109: ...Chapter 12 t slim X2 Pump Info and History...
Страница 111: ...Chapter 13 t slim X2 Pump Reminders...
Страница 116: ...Customer Technical Support 877 801 6901 116 Chapter 13 t slim X2 Pump Reminders THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 117: ...Chapter 14 User Settable Alerts and Alarms...
Страница 120: ...Section 4 t slim X2 Pump Safety Alerts and Alarms...
Страница 121: ...Chapter 15 t slim X2 Pump Alerts...
Страница 143: ...Chapter 16 t slim X2 Pump Alarms...
Страница 157: ...Chapter 17 t slim X2 Pump Malfunction...
Страница 160: ...Section 5 Living With and Caring for Your t slim X2 Pump...
Страница 161: ...Chapter 18 Lifestyle Issues and Travel...
Страница 164: ...Customer Technical Support 877 801 6901 164 Chapter 18 Lifestyle Issues and Travel THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 165: ...Chapter 19 Taking Care of Your t slim X2 Pump...
Страница 168: ...Section 6 Technical Specifications and Warranty...
Страница 169: ...Chapter 20 Technical Specifications...