background image

36

37

About Menus

[Data List] Menu Items (when recording stopped)

[Display Graph]

From the displayed list, select data you wish to view in a graph and tap 

<ENTER>.

[Export Selctd Data]

From the displayed list, select data to export to the SD memory card 

and tap <ENTER>.

IMPORTANT

 -Memory cards are not included. Please purchase separately.
 -

Multiple data files cannot be selected for exporting.

[Export All Data]

Select [OK] to export all data to the SD memory card. 

IMPORTANT

 -

Before inserting an SD memory card into the device, make sure to switch off write 

protection on the memory card.

 -Exporting data to the memory card will not erase it from the device’s internal 

memory. Delete recorded data in the device as necessary.

Supported Memory Cards

SD Memory Cards
SDHC Memory Cards

IMPORTANT

 -SDXC memory cards cannot be used.
 -It is possible to run a quick test to see if your memory card works in MCR-4V. See 

p.42 for details.

[Delete Selctd Data]

While “Processing” is displayed on the LCD, do not perform any 

other operations. This process may take a long time to complete.

Select the data you wish to delete from the displayed list, and tap 

<ENTER>.

* If no operations are performed for a while on the data list screen, you’ll return to 

the previous screen.

* Deleting only a few (1-3) data readings from a list which contains a small number 

of readings may have no effect on memory usage. (see p.43 for how to check 

memory capacity)

[Delete All Data]

[On This Device Only]:

Select [OK] to delete all recorded data on the device currently in 

use.

[On All Devices]:

Select [OK] to delete all recorded data on the Master and all 

connected Slave units all together.

* If you try to perform this operation on a Slave unit, the [Delete All Data] menu 

will only show the [On This Device Only] option.

How to Read Recorded Data Graph

The graph can be scrolled on the display by using 

 or control 

wheel operation to move to the left or right.

2.

3.

4.

1.

5.

6.

7.

1. 

While scrolling, the time of recorded data appears on the top of the 

screen.

Содержание MCR-4V

Страница 1: ...ons of the installation and operation of the MCR 4V Please make sure the following items are included in the package MCR 4V AA Alkaline Battery LR6 x 2 Copyr ight T D Corpo ration All rights reserv ed...

Страница 2: ...manual cannot be reissued so please keep it in a safe place Please read the warranty and provisions for free repair carefully Compliance Information FCC Statement This device complies with Part 15 of...

Страница 3: ...ate and or industrial use only It should not be used in situations where strict safety precautions are necessary such as with medical equipment or in systems directly or indirectly connected with huma...

Страница 4: ...n Areas exposed to excessive smoke dust or dirt CAUTION Other Precautions Use the unit in the specified operating environment Do not use it for any purpose other than for which it was designed Condens...

Страница 5: ...pping Recording by Group 23 About Menus Record Settings Menu 24 Data List Menu 26 Displayed Items when Recording Stopped 26 Displayed Items during Endless Recording 27 Memory Card Menu 28 Operation Se...

Страница 6: ...tings Recording Settings Downloading Recorded Data Use T D Graph for Graph Display Data Analysis Printing and Saving in Text Main Features in Rec Settings Average Value Recording 50 60Hz Filter Increa...

Страница 7: ...desired area of touch panel Press and hold hold down Touch the screen and hold finger in place for a few seconds Mainly used to switch ON OFF the power and key lock Control Wheel Operation rotate Pre...

Страница 8: ...page Running on battery 6 Operation Mode Shows the operation mode status Touchpad operation enabled Control wheel operation enabled Touch Panel disabled 7 These indicate that there are more menu item...

Страница 9: ...is not only possible to transfer data stored in the internal memory to an SD memory card but it is also possible to automatically backup data while recording in endless mode Operations related to the...

Страница 10: ...o may result in loss of data being recorded When you wish to replace batteries while recording is in progress make sure to connect the USB cable to your PC for USB bus power If the MCR 4V runs out of...

Страница 11: ...p 31 CH1 Settings CH4 Settings Also the scale conversion equation can be changed via MCR for Windows About the Trend Graph Display A trend graph is displayed for each channel of data 1 2 3 4 The line...

Страница 12: ...y the Master but Group Recording cannot be started if the measurement interval is less than 100ms When using MCR 4TC as the Master and MCR 4V as the Slave The measurement interval of the Slave is dete...

Страница 13: ...ge on the target connected Slave unit or use MCR for Windows by connecting each Slave unit to the PC with a USB cable Among the above Settings not controlled by the Master the Channel Name and Scale C...

Страница 14: ...24V Auto 2 CH3 Settings Scale Conv OFF ON OFF CH4 Settings Eq y 1 0x 0 0 Unit V Warn Montr OFF OFF Lower Upper Up Low Uppr Limit 3 User Specified Voltage Value Lwr Limit 3 User Specified Voltage Value...

Страница 15: ...51 Export All Data Back OK Delete Selctd Data Back No4 Jul 30 13 16 19 45 No3 Jul 29 13 15 42 51 Delete All Data Back On This Device Only On All Devices 1 1 When selecting Delete All Data on the Slav...

Страница 16: ...r details about Group Recording see p 20 Detailed Sett ON OFF Switch ON OFF the detailed settings When detailed settings is switched to OFF the Rec Method 50 60Hz Filter and Rec Channel menus will not...

Страница 17: ...combina tion of other settings Rec Channel Select the channel s for recording It is possible to select to record using one channel or a combination of channels from Ch1 Ch4 The number of channels whic...

Страница 18: ...warning at the moment it exceeds the set upper or lower limit Preheat OFF User Specified Time Select whether or not to use the preheat function When using the preheat function make settings for the le...

Страница 19: ...for the stop trigger are only detected at the points of input signal measurement at the point of recording even if the conditions are met they will not be detected Save Restore Sett By selecting Save...

Страница 20: ...ee p 42 for details Delete Selctd Data While Processing is displayed on the LCD do not perform any other operations This process may take a long time to complete Select the data you wish to delete fro...

Страница 21: ...n times the recording interval value The horizontal axis of the graph display shows a total of 100 dots 10 dots per box 10 boxes 100 dots There are ten data points dots in each divisional box Enlarge...

Страница 22: ...r carry out a Quick Format see p 42 During the Auto Data Export process other operations cannot be performed except for switching the LCD display between Menu Measurements Trend Graph by pressing Canc...

Страница 23: ...o confirm the contrast Check Memory You can check the memory usage of capacity and the number of recorded data Set Clock 1 Tapping will change the selection item of the display in the order of month d...

Страница 24: ...or recover deleted or corrupted data Do not turn off the power of the MCR 4V during initialization Termination of the initialization process may cause damage or malfunction to the device Using a PC wi...

Страница 25: ...en installed correctly Please see Help for Unit Recognition Failure in the Help menu and check the USB driver Making Settings via PC The following items are not included on the device menu and can onl...

Страница 26: ...Windows By connecting the device to a PC with a USB communication cable it is possible to download recorded data to a PC 1Open MCR for Windows 2Connect the device to your computer 3Click Get List in t...

Страница 27: ...cable during communication between a device and the PC Analyzing Recorded Data Open Recorded Data In the storage folder for the downloaded recorded data on your PC p 48 double click on the desired re...

Страница 28: ...tantaneous values only and the preheat time is set to longer than the waiting time before recording start the first data reading will be invalid because preheating has not been completed 3Q Is it poss...

Страница 29: ...ollowing The software may not have been installed correctly Try reinstalling MCR for Windows Check to see if the software was installed with Administrator rights If after checking and trying the above...

Страница 30: ...From a slave unit Approx 4 minutes 30 seconds External Memory SD Memory Card SDHC Memory Card For Manual or Automatic Data Export Power AA Alkaline Battery LR6 x 2 AA Ni MH Battery x 2 AC Adaptor AD...

Страница 31: ...A list of distributors can be found at tandd com purchasing Product Information Product information can be found at tandd com product Multichannel Voltage Recorder MCR 4V User s Manual 817 1 Shimadach...

Отзывы: