background image

180208-12 5056.4252104 

TCWS.54NG04.C

PART# TCWS.54NG04.C
For TCWS Series C

IMPORTANT:
THESE INSTRUCTIONS ARE TO REMAIN 
WITH THE HOMEOWNER

These instructions are supplementary to the Installation 

and Operating Instructions supplied with the fi replace 

and should be kept together. Refer to the  Installation 

and Operating Instructions for proper gas supply, safety 

requirements and operating instructions.

TCWS.54NG04.C
TRANQUILITY 
BURNER KIT 
INSTRUCTIONS

Содержание TCWS.54NG04.C

Страница 1: ...E HOMEOWNER These instructions are supplementary to the Installation and Operating Instructions supplied with the fireplace and should be kept together Refer to the Installation and Operating Instruct...

Страница 2: ...manual prior to burner installation Page 23 1 Attachfuelflexlineandpilotassembly tobulkhead fittings Fig 1 1 BURNER TRAY ASSEMBLY Fig 1 2 3 4 LBS SAND 4 PEBBLE ASSEMBLIES Includes front and rear pebbl...

Страница 3: ...ectrical bulk head fitting Fig 2 3 Tilt burner tray length wise and insert into the firebox Fig 3 4 While supporting one end of the burner tray connect gas line to the tee on the un derside of the bur...

Страница 4: ...uri tube over the orifice Test for connection by lifting at a location pin on the right side of the burner Repeat with left burner Fig 7 CAUTION The burners should be tightly butted up against each ot...

Страница 5: ...rock to align to the tabs on the pebble clusters Fig 11 below 12 Repeat the sequence of placing the front rear and top rocks three more times until the burner is covered 13 Place equalizer rocks eith...

Страница 6: ...the components supplied with this burner CAUTION The gas supply and electrical power shall be shut off before proceeding with the conversion Note Factory supplied components must be used to ensure co...

Страница 7: ...The minimum rate screw is sealed with an O ring Use a thin bladed screwdriver to back the screw out past the limit of the threading At this point a groove on the screw body will be visible just above...

Страница 8: ...protective backing and apply the conversion label directly overthegasspecificationsontherating label 13 Re locate the control box shield and re attach the access panel to the side of the firebox with...

Страница 9: ...ant will be required to ensure a gas tight connection Note To test the gas pressure turn off the gas supply before removing the plug from the supply pressure test port or manifold pressure test port V...

Страница 10: ...flame ap pearance after the fireplace has reached operating temperature See Fig 26 for proper flame pattern Open primary air if the window glass and firebox have carbon accumulation and or the flames...

Страница 11: ...MAIN SUPPLY TUBE 5019 223 4 PILOT TUBE 5019 229 ITEM DESCRIPTION PART NO 5 PILOT ASSEMBLY CONVERTIBLE 5005 025 6 ORIFICE NATURAL GAS 32 5021 332 A 7 PROPANE CONVERSION KIT TC36 LPCSTE01 8 SAND TC42 S...

Страница 12: ...Printed in Canada Technical support 1 877 715 2664 Web site www townandcountryfireplaces net 2975 Allenby Rd Duncan BC V9L 6V8...

Отзывы: