D14334.02—FEBRUARY 2009
1
Software version TC1.1 FEBRUARY 2009
TANDBERG Codec C60
Administrator Guide
Страница 1: ...D14334 02 FEBRUARY 2009 1 Software version TC1 1 FEBRUARY 2009 TANDBERG Codec C60 Administrator Guide ...
Страница 2: ...stem settings menu 17 The Administrator settings 17 The administrator settings menu Administrator settings 19 The IP Settings menu 19 The Advanced configuration menu 20 The Change password menu 21 Administrator Settings Library Description of the administrator settings 23 The Audio settings 23 The Camera settings 25 The Conference settings 26 The Do not disturb setting 27 The H323 Profile settings...
Страница 3: ...ents Software upgrade 50 Upload certificates 51 XML files 52 Log files 53 NTP Time Zone expressions 54 Supported RFCs in SIP 57 Current RFCs and drafts supported in SIP 57 Media capabilities supported in SIP 57 CE Declaration for Codec C60 58 China RoHS table 59 Dimensions Codec C60 60 PrecisionHD 1080p camera dimensions 61 PrecisionHD camera dimensions 62 Technical specifications 63 ...
Страница 4: ...C60 has been designed to give you many years of safe reliable operation How to read this document You will find that some places information has been copied from other chapters but adapted when needed to let you have all the relevant information there and then This helps eliminating the need to read through long sections before you can even think of getting started Our main objective with this use...
Страница 5: ...ery effort has been made to supply complete and accurate information in this Administrator Guide however TANDBERG assumes no responsibility or liability for any errors or inaccuracies that may appear in this document INTELLECTUAL PROPERTY RIGHTS The Products that are covered by this Administrator Guide are protected under copyright patent and other intellectual property rights of various jurisdict...
Страница 6: ...ers stoves or other apparatus including amplifiers that produce heat Do not place the product in direct sunlight or close to a surface directly heated by the sun Lightning Never use this apparatus or connect disconnect communication cables or power cables during lightning storms Dust Do not operate the apparatus in areas with high concentration of dust Vibration Do not operate the apparatus in are...
Страница 7: ...ves 2002 96 EC WEEE Waste Electrical and Electronic Equipment and 2002 95 EC RoHS The primary aim of the WEEE Directive and RoHS Directive is to reduce the impact of disposal of electrical and electronic equipment at end of life The WEEE Directive aims to reduce the amount of waste electrical and electronic equipment sent for disposal to landfill or incineration by requiring producers to arrange f...
Страница 8: ...e your system Using the remote control Turn on the system Verify IP address settings Setting a static IP address Add the system to the network Verify your settings Time zone settings About monitors This chapter introduces you to the codec and gets you up and going This guide has been divided into several chapters all of which provide different information You can access the chapters directly by cl...
Страница 9: ...ne voltage to the TANDBERG Codec C60 Make sure the codec has been switched off and disconnected from the line voltage whenever connecting or disconnecting other equipment Video to the camera HDMI to HDMI LAN Ethernet Mains Power Cable Loudspeakers optional Camera control cable RJ45 to DSUB Power Switch After having connected the cables you may turn the codec On PC audio to Line In 1 Monitor audio ...
Страница 10: ...y the layout menu then select a view in the menu Batteries Make sure the remote control has working batteries 4 x AAA batteries ARROW UP DOWN Use the up and down arrow keys to navigate in the menu ARROW LEFT Press the left arrow key to go one step back in the menu or to move to the left in a text field ARROW RIGHT Press the right arrow key to expand the selected menu item or to move to the right i...
Страница 11: ...een and the middle part of the remote control is used to handle the video part of the call while the lower part of the remote control resembles very much the keypad of a mobile phone Touch the rubber line sensors along the sides to wake up the system Press the HOME key to show the menu on screen The DIP switch abc 123 Press the key to toggle between lower case characters and numbers 0 9 a z period...
Страница 12: ...t Mask and Gateway address in the address fields The sequence is shown below Press 4 OK to save the changes or Cancel to leave without saving Press 5 Home to exit Verify IP address settings Go to System Information to verify the IP address Navigate to 1 Settings System settings System Information When the IP address is automatically assigned from a DHCP server the 2 network IP address of the codec...
Страница 13: ...ly recommend that you verify the settings by inspecting the System Information list You do this by accessing the System Information in the same way as you did when you verified you IP address setting Go to System Information to verify the settings Navigate to 1 Settings System settings System Information Verify the previous configurations For example if you successfully registered 2 to a SIP serve...
Страница 14: ...administrator settings menus Changing these settings may affect the behavior of the system and should be done by the system administrator NOTE When you define or change the administrator password make sure you save a copy of the password in a safe place Define the password Navigate to Settings System settings Administrator settings Change password On the remote control press the key to toggle betw...
Страница 15: ... set to the default value which is 1280x720 60Hz for HDMI and 1024x768 60Hz for DVI The menu on screen icons and other information OSD on screen display will be moved to the selected output Key sequence If the main monitor is connected to DVI I 2 video output you must run the following shortcut or key sequence on the remote control Disconnect 0 x where x is output 2 Example Set DVI I 2 as the OSD ...
Страница 16: ...c C60 Administrator Guide Contents Introduction Getting started About the menus Administrator settings Settings Library Cameras Appendices Contact us About the menus About the menus In this chapter Explains the menu system Chapter 3 ...
Страница 17: ... tandberg com docs The Home menu The Home menu will be explained in the TANDBERG Profile User Guide Open the Call menu to make a call Open the Presentation menu to select a presentation source Open the Camera control menu to pan tilt or zoom the camera Open the Settings menu to configure the system The Settings menu The Settings menu will be explained in the TANDBERG Profile User Guide Open the La...
Страница 18: ...r Guide Contents Introduction Getting started About the menus Administrator settings Settings Library Cameras Appendices Contact us Administrator settings The administrator settings menu In this chapter Explaining the administrator settings Chapter 4 ...
Страница 19: ...eave without saving If IP Assignment is set to DHCP the IP address Subnet Mask and Gateway will automatically be assigned to the codec from the DHCP server If IP Assignment is set to Static the IP address Subnet Mask and Gateway must be defined manually On the remote control press the arrow down key to highlight an address field Enter the IP address Subnet Mask and Gateway address Press OK to conf...
Страница 20: ...ABC 123 Enter the as many characters as needed until the setting you are searching for displays in the list Changing a value Select a value from a drop down list and press the OK button to save or press the left arrow to leave without saving Enter a value text in a value text field Press Save to save the change or Cancel to leave without saving Changes in the administrator settings may affect the ...
Страница 21: ...ve a copy of the password in a safe place Changes in the administrator settings may affect the behavior of the system and should be configured by the system administrator HOME SETTINGS SYSTEM SETTINGS ADMINISTRATOR SETTINGS SET PASSWORD Set a new password On the remote control press the key 1 to toggle between lower or upper case characters and numbers abc ABC 123 Enter the password The password y...
Страница 22: ... Not Disturb H323 Network Network Services Phone Book Server Provisioning Serial Port SIP Standby System Unit Video Chapter 5 This chapter gives a detailed description of the administrator settings The administrator settings defines the system settings and are structured in a hierarchy making up a database of system settings Note The description of the Administrator settings are preliminary and su...
Страница 23: ...e for a complete overview of the menu values represented in dB Range 0 to 18 dB Example Audio Input Microphone 1 Level 14 Audio Input Microphone 1 4 EchoControl Mode On Off The echo canceller continuously adjusts itself to the audio characteristics of the room and compensate for any changes it detects in the audio environment If the changes in the audio conditions are very significant the echo can...
Страница 24: ...nable the Audio Line output Off Set to Off to disable the Audio Line output Example Audio Output Line 1 Mode On Audio Output Line 1 Type Auto SPDIF Applies to Line 1 Determines if the Audio Line output is an analog or digital type output Addresses the specified Audio Line output Auto The system will select analog or digital SPDIF mode depending on the detected Audio Module If a TANDBERG Digital NA...
Страница 25: ...ther to control the camera brightness manually or to have it automatically adjusted by the system Addresses the specific camera Auto When set to Auto the camera brightness is automatically set by the system Manual Set to Manual to enable manual control of the camera brightness e g the level of the brightness level setting will be used for the camera Example Cameras Camera 1 Brightness Mode auto Ca...
Страница 26: ...ay be useful in difficult lighting conditions where changes to the the brightness setting does not provide satisfactory results Requires the Gamma Mode to be set to Manual Addresses the specific camera Range 0 7 Example Cameras Camera 1 Gamma Level 0 Conference 1 1 AutoAnswer Mode On Off The Autoanswer setting determines whether an incoming call is put through automatically or manually On The syst...
Страница 27: ...d by the system within the given range Firewall administrators should not try to deduce which ports are used when as the allocation schema within the mentioned range may change without any further notice Static When set to Static the ports are given within a static predefined range 5555 6555 Example H323 Profile 1 PortAllocation Dynamic H323 Profile 1 1 H323Alias ID S 0 49 Lets you specify the H 3...
Страница 28: ...sword H323 Profile 1 1 Authentication Mode On Off On If the H 323 Gatekeeper Authentication Mode is set to On and a H 323 Gatekeeper indicates that it requires authentication the system will try to authenticate itself to the gatekeeper Requires the Authentication ID and Authentication Password to be defined on both the codec and the Gatekeeper Off If the H 323 Gatekeeper Authentication Mode is set...
Страница 29: ...t string with a maximum of 64 characters Example Network 1 IPv4 Address 10 47 5 100 Network 1 1 IPv4 SubnetMask S 0 64 Defines the IP subnet mask Only applicable if Static IP assignment is chosen Format Compact string with a maximum of 64 characters Example Network 1 IPv4 SubnetMask 255 255 255 0 Network 1 1 IPv4 Gateway S 0 64 Defines the IP default gateway Only applicable if Static IP assignment...
Страница 30: ...rative attention SNMP exposes management data in the form of variables on the managed systems which describe the system configuration These variables can then be queried set to ReadOnly and sometimes set set to ReadWrite by managing applications Off Set to Off when you want to disable the SNMP network service ReadOnly Set to ReadOnly when you want to enable the SNMP network service for queries onl...
Страница 31: ...aced Calls Missed Calls and Received Calls Auto The system will use the NTP server by which address is supplied from the DHCP server in the network If no DHCP server is used or the DHCP server does not provide the system with a NTP server address the system will use the static defined NTP server address specified by the user Manual The system will always use the static defined NTP server address s...
Страница 32: ...A list can be uploaded using the web interface If no such CA list is available on the system then anonymous Diffie Hellman will be used Auto The system will try to connect using transport protocols in the following order TLS TCP UDP Example SIP Profile 1 DefaultTransport Auto SIP Profile 1 1 TlsVerify On Off For TLS connections a CA list can be uploaded from the web interface On Set to On to verif...
Страница 33: ...ith a maximum of 50 characters Example SIP Profile 1 Authentication 1 LoginName SIP Profile 1 1 Authentication 1 1 Password S 0 50 This is the password part of the credentials used to authenticate towards the SIP proxy Format String with a maximum of 50 characters Example SIP Profile 1 Authentication 1 Password The System unit settings The Standby settings SystemUnit Name S 0 50 Enter a System Nam...
Страница 34: ...logYPbPr as the component YPbPr signal cannot be auto detected Example Video Input DVI 2 Type AutoDetect Video Input Source 1 3 CameraControl Mode On Off Determines whether or not the camera control should be enabled for the specific video input source Addresses the specific video input source On Set to On to enable camera control for the camera connected to the selected video input connector Off ...
Страница 35: ...han high resolution and vice versa The Quality setting specifies whether to give priority to high frame rate or to high resolution for a given source Addresses the selected video input connector Motion Gives the highest possible framerate Used when there is a need for higher frame rates typically when a large number of participants are present or when there is a lot of motion in the picture Sharpn...
Страница 36: ...ndices Contact us The settings library The Experimental menu The Advanced configurations menu has an option called Experimental The settings within this menu can be used as is and will not be documented NOTE The Experimental menu WILL change We recommend you visit the TANDBERG web site regularly for updated versions of the manual Go to http www tandberg com docs ...
Страница 37: ...ntact us Cameras Cameras Chapter 8 In this chapter The PrecisionHD 1080p camera Connecting the camera Best view Face recognition Video output formats Cameras in daisy chain Your TANDBERG PrecisionHD 1080p Camera has been designed to give you many years of safe reliable operation Additional information about the camera is found in the TANDBERG PrecisionHD 1080p User Guide ...
Страница 38: ...mum resolution is 1080p30 The HDMI and HD SDI can be used simultaneously The maximum resolution is then 1080p30 if you want both to run with the same resolution Kensington lock The Kensington lock may be used to prevent the camera to be moved from its place or to prevent theft Cascaded cameras The sockets named Extra Camera Out and Power In are used when connecting cameras in daisy chain The first...
Страница 39: ... adapter HD SDI socket HDMI and HD SDI can be used simultaneously VISCA is a trademark of Sony Corporation The PrecisionHD 1080p camera cont Connecting the camera The HDMI and HD SDI can be used simultaneously HDMI cable The HDMI cable delivered with the camera is 5 meters Maximum length is 15 meter with a category 2 certified good quality HDMI cable HD SDI cable The HD SDI cable must be purchased...
Страница 40: ...ion process may take up to 5 seconds The detection of faces works better when people look towards the camera The area from the eyebrows down to just below the lips should be uncovered Beard is normally not a problem Using Best view Note that Best view works with TANDBERG C60 C90 Codecs only Press the 1 Layout key on the remote control to display the Layout menu Select Selfview to be shown as requi...
Страница 41: ...ltage frequency when it is 50 or 60Hz You may set the video output format to a specific value use the DIP switches to override the auto frequency detection if a different line voltage frequency is an issue DIP Switch table for video formats 1 2 3 4 5 HDMI HD SDI 0 0 0 0 0 Auto 0 0 0 0 1 1920x1080p25 1920x1080p25 0 0 0 1 0 1920x1080p30 1920x1080p30 0 0 0 1 1 1920x1080p50 1280x720p50 0 0 1 0 0 1920x...
Страница 42: ... used simultaneously on the same camera Power The first camera in the chain is powered up from the codec by the VISCA camera control cable Additional cameras must use the 12V DC Power in Extra camera cable The daisy chained cameras are connected by using the VISCA Extra Camera cable between the Extra Camera In and Codec Control In sockets Main camera Second camera Third camera Connect to the Camer...
Страница 43: ... codec HDMI HDMI is the main source for video out when connected to a Codec C60 Maximum resolution is 1280x720p30 This output does not support HDCP High Bandwidth Digital Content Protection Cascaded cameras The sockets named Extra Camera and Power In are used when connecting cameras in daisy chain The first camera in the chain is powered up by the camera control cable The next cameras must use the...
Страница 44: ... us Appendices Appendices Chapter 7 In this chapter General room guidelines Meeting room setup Software upgrade Upload certificates XML files Log files NTP Time Zone expression Supported RFCs in SIP Remote Control TRC5 Remote Control key map PrecisionHD camera CE Declaration China RoHS Codec C60 dimensions PrescisionHD 1080p dim PrescisionHD dimensions Technical specifications ...
Страница 45: ...ipants in the room Use the pan tilt and zoom features to adjust the picture The PC PC s placed on the table should not cover the microphones as this will reduce the audio quality at the far end Position of the system Position the video system in such a way that all participants attending the meeting are visible to the far end If appropriate the far end should be able to see people entering or leav...
Страница 46: ...mmunication between the people Adjust the camera view using zoom in out to allow the participants to be shown in full size on screen and to keep eye contact with each other at the same eye level If the participants are sitting too close to the monitor the camera will look down at the participants This may not give a good presentation of the participants at the far end The far end participants The ...
Страница 47: ...ther at the same eye level The camera should capture all participants in the room If the participants are sitting too close to the monitor the camera will look down at the participants This may not give a good presentation of the participants at the far end The speaker module There should be free sight between the system speaker module and the ear of the participants The microphones The microphone...
Страница 48: ...ion button on the remote control the 3 default presentation source is activated The DVI VGA input is compliant with VESA Extended Display Identification Data EDID and will be able to notify the PC of the supported output formats Troubleshooting if the presentation does not show On most PC s you must press a special key combination to switch the PC image from the PC screen to the video screen Make ...
Страница 49: ...he key to zoom the camera in and out Arrows Up Down Use the and arrow keys to navigate in the menu Arrow Right Press the arrow key to expand the selected menu item or to move to the right in a text field Arrow Left Press the arrow key to go one step back in the menu or to move to the left in a text field Layout Press the key to display the Layout menu then select a view in the menu End call Standb...
Страница 50: ...grade The Upgrade tab lets you select the software upgrade file for TANDBERG Codec C60 and install the new software Please follow the procedure described on this page Open a web browser and enter the 1 IP address to connect to the Codec C60 by HTTP Select the 2 Upgrade tab Click 3 Browse and locate the upgrade file PKG Click the 4 Install software button to start the installation Leave the system ...
Страница 51: ...ach system For TLS connections a ROOT Certificate CA list can be uploaded from the web interface When the SIP setting TlsVerify is enabled only TLS connections to servers whom x 509 certificate is validated against the CA list will be allowed Go to Settings Administrator settings Advanced configuration SIP Profile TlsVerify To install a certificate you need HTTPS certificate PEM format ROOT certif...
Страница 52: ...ng disabling of various features etc The configuration commands are structured in a hierarchy making up a database of system settings Status Status type commands returns information about the system and system processes and are issued from the API Status type commands are read by the user Example Information generated by the system about ongoing calls network status conference status etc All statu...
Страница 53: ...t us Appendices Debug log files Select a debug log file by clicking on the name of the file Some of the log files can be opened or saved Log files In the Logs tab you will find debug log files These are TANDBERG specific debug files which may be required by TANDBERG in the need of technical support Some of the log files can be saved You will then see the following dialog box ...
Страница 54: ... America Campo_Grande America Cancun America Caracas America Catamarca America Cayenne America Cayman America Chicago America Chihuahua America Coral_Harbour America Cordoba America Costa_Rica America Cuiaba America Curacao America Danmarkshavn America Dawson America Dawson_Creek America Denver America Detroit America Dominica America Edmonton America Eirunepe America El_Salvador America Ensenada ...
Страница 55: ...Gaza Asia Harbin Asia Ho_Chi_Minh Asia Hong_Kong Asia Hovd Asia Irkutsk Asia Istanbul Asia Jakarta Asia Jayapura Asia Jerusalem Asia Kabul Asia Kamchatka Asia Karachi Asia Kashgar Asia Katmandu Asia Kolkata Asia Krasnoyarsk Asia Kuala_Lumpur Asia Kuching Asia Kuwait Asia Macao Asia Macau Asia Magadan Asia Makassar Asia Manila Asia Muscat Asia Nicosia Asia Novosibirsk Asia Omsk Asia Oral Asia Phnom...
Страница 56: ...ockholm Europe Tallinn Europe Tirane Europe Tiraspol Europe Uzhgorod Europe Vaduz Europe Vatican Europe Vienna Europe Vilnius Europe Volgograd Europe Warsaw Europe Zagreb Europe Zaporozhye Europe Zurich Factory GB GB Eire GMT GMT 0 GMT0 GMT 0 Greenwich Hongkong HST Iceland Indian Indian Antananarivo Indian Chagos Indian Christmas Indian Cocos Indian Comoro Indian Kerguelen Indian Mahe Indian Maldi...
Страница 57: ...onses in SIP RFC 3263 Locating SIP Servers RFC 3264 An Offer Answer Model with SDP RFC 3311 UPDATE method RFC 3361 DHCP Option for SIP Servers RFC 3420 Internet Media Type message sipfrag RFC 3515 Refer method RFC 3550 RTP A Transport Protocol for Real Time Applications RFC 3581 Symmetric Response Routing RFC 3605 RTCP attribute in SDP RFC 3711 The Secure Real time Transport Protocol SRTP RFC 3840...
Страница 58: ...of conformity MANUFACTURER TANDBERG Telecom AS PRODUCT NAME TANDBERG Codec C60 TYPE NUMBER TTC6 10 DESCRIPTION Video Conferencing Equipment DIRECTIVES This equipment complies with LVD 2006 95 EC EMC 2004 108 EC HARMONIZED STANDARDS Applied in order to verify compliance with directives EN 60950 1 2006 EN 55022 2006 EN 55024 1998 A1 2001 A2 2003 EN 61000 3 2 2006 EN 61000 3 3 1995 A1 2001 A2 2005 TE...
Страница 59: ... Codec C60 Administrator Guide Contents Introduction Getting started About the menus Administrator settings Settings Library Cameras Appendices Contact us Appendices China RoHS table This product complies with the Chineese RoHS ...
Страница 60: ...or Guide Contents Introduction Getting started About the menus Administrator settings Settings Library Cameras Appendices Contact us Appendices Dimensions Codec C60 Dimensions in mm 8 0 1 1 5 2 0 8 7 2 0 2 4 4 0 4 4 Front view Left side view Top view ...
Страница 61: ...ng started About the menus Administrator settings Settings Library Cameras Appendices Contact us Appendices 220 0 105 0 20 5 105 9 eye centre 32 2 148 1 114 6 ø82 0 ø79 6 2 5 2 5 62 4 125 4 142 0 4 4 63 0 190 0 14 0 34 5 191 0 106 3 PrecisionHD 1080p camera dimensions Dimensions in mm ...
Страница 62: ... 2009 62 Codec C60 Administrator Guide Contents Introduction Getting started About the menus Administrator settings Settings Library Cameras Appendices Contact us Appendices PrecisionHD camera dimensions Dimensions in mm ...
Страница 63: ...00 30fps SVGA 1024 x 768 30fps XGA 1280 x 1024 30fps SXGA 1280 x 720 30fps HD720p30 1920 x 1080 30fps HD1080p30 AUDIO STANDARDS G 711 G 722 G 722 1 64 bit 128 bit MPEG4 AAC LD AAC LD Stereo AUDIO FEATURES CD Quality 20KHz Mono and Stereo Four separate acoustic echo cancellers 4 port Audio mixer Automatic Gain Control AGC Automatic Noise Reduction Active lip synchronization AUDIO INPUTS 7 INPUTS 4 ...
Страница 64: ...perature 10 to 90 Relative Humidity RH STORAGE AND TRANSPORT TEMPERATURE 20 C to 60 C 4 F to 140 F at RH 10 90 non condensing APPROVALS Directive 2006 95 EC Low Voltage Directive Standard EN 60950 1 Directive 2004 108 EC EMC Directive Standard EN 55022 Class B Standard EN 55024 Standard EN 61000 3 2 3 3 Approved according to UL 60950 1 and CSA 60950 1 07 Complies with FCC15B Class B DIMENSIONS Len...
Страница 65: ...ces Contact us Contact us U S HEADQUARTERS TANDBERG 1212 Avenue of the Americas 24th Floor New York NY 10036 Telephone 1 212 692 6500 Fax 1 212 692 6501 Video 1 212 692 6535 E mail tandberg tandberg com EUROPEAN HEADQUARTERS TANDBERG Philip Pedersens vei 20 1366 Lysaker Norway Telephone 47 67 125 125 Fax 47 67 125 234 Video 47 67 126 126 E mail tandberg tandberg com ...