© Copyright International Business Machines Corporation 2000.
All rights reserved. US Government Users Restricted Rights –
Use, duplication or disclosure restricted by GSA ADP Schedule
Contract with IBM Corp.
© Copyright Tandberg Data ASA, 2004
Quick Start Guide
Tandberg 440LTO External Tape Drive
0043 2630-1 Tandberg Data Cartridge LTO1
0043 2744-1 Tandberg Data Cartridge LTO2
043 2631 LTO Cleaning Cartridge
Single-Character Display
No error.This code displays:
When power is cycled (turned off, then on) to the tape
drive
When diagnostics have finished running and no error
occurred
0
1
2
3
4
5
6
7
8
9
A
C
The maximum operating temperature was exceeded.
The externally supplied power is outside the specified
voltage limits.
A firmware error occurred.
A firmware or tape drive hardware failure occurred.
A tape drive hardware failure occurred.
A tape drive or media error occurred, but cannot be
isolated to faulty hardware or to the tape cartridge.
A media error occurred because of a faulty tape cartridge.
A tape drive or SCSI bus error occurred.
A tape drive or RS-422 error occurred.
A tape drive hardware failure has occurred for conditions
NOT covered by error code 5.
The tape drive needs to be cleaned.
Tape Storage Solution
Tape Storage Solution