3.3. Connection of LEDs 

To display the busy signals (e.g. in 
analogue systems), connect the 
cathodes (-) of LEDs (with series 
resistors, e.g. 1 kΩ) to the outputs of 
the GBM-8.2.  

Always with series resistor!

Never operate LEDs without a series 
resistor, the LEDs will be destroyed 
very quickly in this case! 

Separate transformer!

Do not use the driving transformer for 
the power supply of the LEDs, but a 
separate transformer, e.g. to supply 
other lights! If you use the driving 
transformer to supply the LEDs, the 
equalising currents that occur can 
damage connected components. 

Supply with alternating voltage

If you connect the LEDs to an AC transformer, you should also connect a protective diode
(e.g. 1N400x, x=2...7) and a capacitor with a capacity between 10 and 100 µF and a dielectric
strength of at least 25 V. This will prevent the LEDs from flickering. 

No incandescent lamps! 

Never connect incandescent lamps to the outputs, as they usually consume more than 50
mA of current. The outputs of the GBM-8.2, which are designed for a maximum current of
50 mA, would be destroyed during commissioning!

10 | Connections GBM-8.2 

Содержание GBM-8.2

Страница 1: ...GBM 8 2 Track Occupancy Indicator 8 fold Manual Item no 52 01186 52 01187 tams elektronik n n n...

Страница 2: ...technical changes Printing the manual The formatting is optimised for double sided printing The standard page size is DIN A5 If you prefer a larger display printing on DIN A4 is recommended The asteri...

Страница 3: ...Connections GBM 8 2 8 3 1 Connecting the power supply and the track sections 8 3 3 Connection of LEDs 10 3 4 Connection of digital feedback modules 11 4 Setting the sensitivity 12 5 Checklist for tro...

Страница 4: ...Stranded wires consist of several thin individual wires and are therefore more flexible than rigid wires with the same copper cross section Recommended cross sections Connections to the tracks and the...

Страница 5: ...oltage as specified in the technical data Use only tested and approved transformers Only plug the mains plugs of transformers into properly installed and fused earthed sockets When making electrical c...

Страница 6: ...cted directly to the outputs Display of the busy messages To display the busy messages LEDs with suitable series resistors can be connected to the outputs of the GBM 8 2 Since the outputs of the GBM 8...

Страница 7: ...nputs and outputs of the GBM 8 2 are galvanically separated from each other by optocouplers This filters out interference peaks and effectively prevents ground loops hum loops and fault currents Info...

Страница 8: ...to 3 rail systems Connecting the power supply Please note that all track sections must be in one booster circuit or must be supplied via a common driving transformer GBM 8 2 Track output of the booste...

Страница 9: ...re detected that enter the track section in the direction marked as direction of travel in the connection diagram GBM 8 2 Connection to G1 G2 G3 G8 isolated conductors in the track sections V1 uninter...

Страница 10: ...If you use the driving transformer to supply the LEDs the equalising currents that occur can damage connected components Supply with alternating voltage If you connect the LEDs to an AC transformer yo...

Страница 11: ...les You can connect the inputs of digital feedback modules that switch to ground e g s88 feedback modules directly to the outputs of the GBM 8 2 Connect the ground output of the feedback module to one...

Страница 12: ...ensitivity of the track occupancy detector for each of the 8 track sections at the associated trim pot Use a small screwdriver for the adjustment Settings Left stop highest sensitivity setting on deli...

Страница 13: ...ut the use of your track occupancy indicator our technical hotline will help you telephone number and e mail address on the last page 5 2 Repairs You can send us a defective track occupancy indicator...

Страница 14: ...ly via the rails Note All track sections must be in one booster circuit or supplied via a common driving transformer Current consumption without connected loads approx 15 mA Max current in the track s...

Страница 15: ...ion 10 85 non condensing Ambient temperature during storage 10 40 C Permissible relative humidity during storage 10 85 non condensing Other features Dimensions approx Circuit board 63 x 97 mm Ready de...

Страница 16: ...of the components as well as the function of the parts according to the parameters in not mounted state We guarantee the adherence to the technical specifications when the kit has been assembled and t...

Страница 17: ...s product is subject to the requirements of the EU Directive 2012 19 EC on Waste Electrical and Electronic Equipment WEEE i e the manufacturer distributor or seller of the product must contribute to t...

Страница 18: ...GBM 8 2 tams elektronik 18...

Страница 19: ...tams elektronik GBM 8 2 19...

Страница 20: ...ation and Tips n n http www tams online de n n n n Warranty and Service n n Tams Elektronik GmbH n Fuhrberger Stra e 4 DE 30625 Hannover n fon 49 0 511 55 60 60 fax 49 0 511 55 61 61 n e mail modellba...

Отзывы: