tams elektronik

ARTEMIS

English

2. Safety instructions

Mechanical hazards

Cut wires can have sharp ends and can cause serious injuries. Watch
out for sharp edges when you pick up the PCB. 
Visibly   damaged   parts   can   cause   unpredictable   danger.   Do   not   use
damaged parts: recycle and replace them with new ones.

Electrical hazards

Touching powered, live components,

touching conducting components which are live due to malfunction,

short   circuits   and  connecting   the   circuit   to   another   voltage   than
specified,

impermissibly high humidity and condensation build up

can  cause   serious  injury  due   to  electrical  shock.   Take  the  following
precautions to prevent this danger:  

Never perform wiring on a powered module.

Assembling   and   mounting   the   kit  should   only   be   done   in   closed,
clean, dry rooms. Beware of humidity.

Only use low power for this module as described in this manual and
only use certified transformers.

Connect  transformers  and  soldering  irons only  in approved   mains
sockets installed by an authorised electrician.

Observe cable diameter requirements.

After   condensation   build   up,   allow   a   minimum   of   2   hours   for
dispersion. 

Use only original spare parts if you have to repair the kit or the
ready-built module.

Page 5

Содержание 46-00117

Страница 1: ...t a m s e l e k t r o n i k Manual ARTEMIS Item no 46 00117 HUB for a sublevel with 32 nodes tams elektronik n n n...

Страница 2: ...ttings 15 6 1 Identify button 15 6 2 Firmware Update 15 7 Operation 16 8 Check list for troubleshooting 18 9 Guarantee bond 20 10 EU declaration of conformity 21 11 Declarations conforming to the WEEE...

Страница 3: ...peration Before you start we advise you to read the whole manual particularly the chapter on safety instructions and the checklist for trouble shooting You will then know where to take care and how to...

Страница 4: ...ical data output voltage 12 18 V direct voltage DC output current at least 1 A If you use a power supply unit without an integrated cable make sure that the cross section of the supply cable is suffic...

Страница 5: ...d impermissibly high humidity and condensation build up can cause serious injury due to electrical shock Take the following precautions to prevent this danger Never perform wiring on a powered module...

Страница 6: ...re inattentive and not responsible enough Children under the age of 14 should not be allowed to work with this module In schools training centres clubs and workshops assembly must be supervised by qua...

Страница 7: ...the wiring of individual system parts or component groups can be clearly grouped in sublevels The extension of a layout or the addition of additional stationary components is very easy Changes and add...

Страница 8: ...ponents The numbers in the figure were dialled in analogy to the addresses that the components receive according to the BiDiB protocol However they are only intended here to clarify the structure Tip...

Страница 9: ...on of messages from and to further nodes in a sub level According to the BiDiB specification ARTEMIS transmits all system messages as well as all messages for node management NEW LOST etc ARTEMIS is o...

Страница 10: ...mption without connected devices max 25 mA Data Protocols BiDiB Interfaces for BiDiBus Main level 2 RJ 45 sockets Sub level 2 RJ 45 sockets for max 31 further BiDiB nodes Output current for BiDiB comp...

Страница 11: ...Connecting ARTEMIS 5 1 Pin assignment 1 Power Voltage supply 12 18 V direct voltage 2 Main level BiDi Bus 3 TERM DCC BiDiB Final jumper DCC BiDiB termination 4 SUB TERM DCC BiDiB Sub level Final jumpe...

Страница 12: ...possibly irreparably during commissioning Never connect digital components which are integrated in a conventional digital controller with digital central unit to a power supply unit which is used to s...

Страница 13: ...g to the BiDiBus specification patch cables with RJ 45 connections Cat5 cable are provided as bus cables for ARTEMIS These cables are easy and quick to handle and ensure secure connections to the inte...

Страница 14: ...ncerned If you subsequently connect one or more devices to the second BiDiB port you must remove the termination jumpers Note If you do not set termination jumpers on a hub installed at one end of the...

Страница 15: ...idge in the screen display of the control software press the Identify button on the board The associated BiDiB node is then highlighted on the screen and the LED on the hub flashes 6 2 Firmware Update...

Страница 16: ...he operating states Power on fast flickering Device in operation double flashing Registration on the bus was refused Section 8 Identify off no connection to the BiDi bus permanent lighting connected t...

Страница 17: ...k fast flashing Bus voltage in the sublevel faulty Section 8 Error messages Power on Identify Message 10 x fast flashing No bootloader found no firmware update possible Contact the Tams Elektronik Hot...

Страница 18: ...at the BiDi Bus is rejected Display Double flashing of the LED Identify Possible cause More than 32 components including ARTEMIS are connected to the BiDi Bus in the main level Check the number of com...

Страница 19: ...maximum fee for the repair is 50 of the current sales price according to our valid price list We reserve the right to reject the repairing of a module when the repair is impossible for technical or ec...

Страница 20: ...lity of the components as well as the function of the parts according to the parameters in not mounted state We guarantee the adherence to the technical specifications when the kit has been assembled...

Страница 21: ...led by an authorised electrician Make no changes to the original parts and accurately follow the instructions connection diagrams and PCB layout included with this manual Use only original spare parts...

Страница 22: ...t a m s e l e k t r o n i k English ARTEMIS Page 22...

Страница 23: ...t a m s e l e k t r o n i k ARTEMIS English Page 23...

Страница 24: ...n Information and tips n n http www tams online de n n n Warranty and service n n Tams Elektronik GmbH n Fuhrberger Stra e 4 DE 30625 Hannover fon 49 0 511 55 60 60 fax 49 0 511 55 61 61 e mail model...

Отзывы: