 TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 

Use this unit in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. 

Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on 

accidentally. When the service disconnecting cannot be locked, securely fasten a prominent warning device, such as a tag, to the 
service panel. 

When cutting or drilling into wall or ceiling, do not damage electrical wiring or other hidden utilities. 
Never place a switch where it can be reached from a tub or shower. 
Do not use this fan over a tub or shower. 
Do not use this fan over cooking appliances. 

CAUTION:

 For General Ventilation Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors 

CAUTION:

 This unit has an unguarded impeller. Do Not Use in Locations Readily Accessible to People or Animals.  

 

The Best Location for 

The

 

Infinity 

 

1. When selecting fan mounting location, consider the following:  
a) Mounting 

The

 

Infinity

 as far as possible from the interior air intake or exhaust points will 

minimize fan operating noise from being transmitted back through the duct work.  

      Insulated flexible type duct work will result in much quieter operation.  
b) 

The

 

Infinity

 location should allow sufficient access for service. 

2. Attach fan to the mounting bracket with the nuts and bolts provided. The wiring box should be 

positioned for easy access. 

3. Using the wood screws provided, attach the mounting brackets to a rafter or support beam at the 

selected location.  

4. Connect ductwork to the inlet and outlet collars of 

The

 

Infinity

 using clamps or duct tape. When 

using insulated duct, it is recommended that the inner vinyl core be clamped or taped to the 
collars and that the vapor barrier surrounding the insulation be duct taped to the housing. 

 
 
 
 

 
 
 

 

 
 

 

SPECIFICATIONS: 

Duct Size (4): 

 

 

 

10” 

Duct Collar Length: 

 

 

3” with Bead 

Electrical Requirements: 

 

115V, 60Hz, 3A (Total) 

Overall Dimensions: 

 

 

30”W x 17-1/8”H x 9.5D 

Mounting Flange Dimensions 

 

27” x 1-1/2” 

Unit Weight 

 

 

 

27 Lbs 

Air Flow (each motor)   

 

1070 cfm @ .1” Wg 

 
 