Tamarack Technologies HV series Скачать руководство пользователя страница 1

HV Series 

Whole House Ventilators 

Product Manual & Installation Guide

 

HVM.03 

 

PLEASE LEAVE WITH HOMEOWNER 

Read all instructions carefully before installing your HV 

 

Serial Number _________ Date of Purchase __________Point of Purchase _________________ 

The serial number is located on the shipping carton and on a label affixed to the upper housing. 
 

Unpacking your HV:

 

When you have unpacked your HV carefully you will find the following: 

 
 

 
 
 
 

 

 

The Best Location for your HV:

 The HV should be installed in your attic in a central location within your 

home. Above a central hallway or at the top of a stairwell will provide the best airflow. The fan can be mounted vertically.    
► Make sure that there aren’t any pipes, wires, rafters or air conditioning or heating ducts running through the space 
where the HV will be installed and that the doors will open into an unoccupied area.   
► Make sure that you have adequate exhaust area out of your attic. This can be accomplished with a combination of roof, 
ridge, soffit or gable end vents or other attic exhaust points. The HV1000 requires a minimum of 2 square feet and the 
HV1600 requires 3.5 square feet of clear exhaust area. Allow 50% loss of clear area for louvers and screens 
► Make sure that there is enough clearance above the fan for the doors to open.  The minimum requirement for the HV 
with R22 insulating 

doors is 11” and 12” is required for models with R38 insulating doors. 

       

                                  

 

WARNING 

To reduce the risk of 

Fire, Electric Shock

, or 

Injury 

to persons, observe the following: 

Use this unit in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. 

 

Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and 

standards, including fire rated construction. 

Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being 

switched on accidentally.  When the service disconnecting can not be locked, securely fasten a prominent warning device, 
such as a tag, to the service panel. 

When cutting or drilling into wall or ceiling, do not damage electrical wiring or other hidden utilities. 

Never place a switch where it can be reached from a tub or shower. 

Do not use this fan over cooking appliances.  

Do not use this fan over a tub or shower. 

Do not use this fan with any solid state speed control device. 

CAUTION: For general ventilation use only. Do not use to exhaust hazardous or explosive materials and vapors. 

 

 

Tamarack Technologies, Inc.• 320 Main Street • Buzzards Bay,  MA 02532 
 508-759-

4660  •  800-222-5932  •  Fax 508-759-6001                             www.tamtech.com 

HV1000  

One (1) HV1000 Whole House Ventilator

 

One (1) White Metal Grille w/(6) Screws

 

One (1) Package of Foam Gasket

 

One (1) Electrical Box Cover w/(2) Screws

 

One (1) Wall Switch (SPST)

 

Four (4) #8x3/4 Screws 
One (1) Grounding Screw (green)

 

HV1600  

One (1) HV1600 Whole House Ventilator

 

One (1) White Metal Grille w/(6) Screws

 

One (1) Package of Foam Gasket

 

Four (4) #8x3/4 Screws

 

One (1) Hand Held Remote Transmitter 

 

 

Содержание HV series

Страница 1: ...insulating doors WARNING To reduce the risk of Fire Electric Shock or Injury to persons observe the following Use this unit in the manner intended by the manufacturer If you have any questions contact the manufacturer Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction Before servicing ...

Страница 2: ...ealant not supplied 4 Set the HV on the gasket with the doors facing to open into the attic The lower housing will fit into the box with the mounting flanges overlapping the joists Figure 4 The HV should not be forced into this opening Forcing it into place may cause the doors to bind and not function properly 5 If desired secure the HV to the top of the joists using the 8x3 4 screws provided When...

Страница 3: ...ng these switches will override the remote control function The HV whole house cooling fans are not for use with solid state speed controls Specifications Voltage Power HV1000 HV1600 Airflow 03 System HV1000 HV1600 High HV1600 Low 115VAC 60 Hz 147 Watts 227 Watts 1000 CFM 1600 CFM 900 CFM R Value HV1000 HV1600 GR HV1000 DB HV1600 GDR Weight HV1000 HV1600 Rough Opening Grille Dimensions Grille Colo...

Страница 4: ...of three years from the date of purchase the HV 1000 or HV 1600 the Product is defective or malfunctions in normal home use Tamarack Technologies Inc will repair or replace the Product at its discretion Customer is responsible for shipping charges NOTE Some states codes require fans to be hardwired Hardwiring of the HV1600 will not void warranty provided the wiring is performed by a licensed elect...

Отзывы: