  Installer Responsibility

 

The installer is solely responsible for: 

i.

 

Complying with all applicable local or national building codes, including any that may supersede this manual;  

ii.

 

Ensuring that Tamarack Solar and other products are appropriate for the particular installation and the 

installation environment; 

iii.

 

Using only Tamarack Solar parts and installer-supplied parts as specified by Tamarack Solar. Substitution 

parts may void the warranty; 

iv.

 

Ensuring safe installation of all electrical aspects of the PV array; and 

v.

 

Ensuring correct and appropriate design parameters are used in determining the design loading used for the 

specific installation. Parameters, such as snow loading, wind speed, exposure and topographic factor should 

be confirmed with the local building official or a licensed professional engineer. 

 

Warranty  Information

 

Tamarack Solar warrants each Mounting Structure to be free from defects in materials and workmanship for ten (10)  

years from the date of first purchase (“Warranty Period”), when installed properly and used for the purpose for  which it is 

designed, except for the finish, which shall be free from visible peeling, or cracking or chalking under normal atmospheric 

conditions   for a period of three (3) years, from the earlier of 1) the date the installation of the  Product is completed, or 2) 

30 days after the purchase of the Product by the original Purchaser (“Finish Warranty”).  The Finish Warranty does not 

apply to any foreign residue deposited on the finish. 

 

Galvanized coated sheet steel components will show rust on cut edges and is normal and will not affect the structure 

and function of the mount. 

 

All installations in corrosive atmospheric conditions are excluded.

 The Finish Warranty is VOID if the practices specified 

by AAMA 609 & 610-02 – “Cleaning and Maintenance for Architecturally Finished Aluminum” (www.aamanet.org) are not 

followed by Purchaser for Tamarack Solar’s aluminum based products. 

 

The warranty covers the replacement cost of parts to repair the product to proper working condition.  Transportation and 

incidental costs associated with warranty items are not reimbursable. The warranty does not   cover normal wear, or 

damage resulting from misuse, abuse, improper installation, negligence, or accident, or 

typographical errors in instruction 

manuals.

 The Warranty does not cover any defect that has not been reported in writing to Tamarack Solar within ten (10) 

days after discovery of such defect. Furthermore, it does not cover units that have been altered, modified or repaired 

without written authorization from the manufacturer or its authorized representative, or units used in a manner or for a   

purpose other than that specified by the manufacturer. Tamarack Solar’s entire liability and Purchaser exclusive remedy, 

whether in contract, tort or otherwise, for any claim related to or arising out of breach of the warranty covering the 

Mounting Structures shall be correction of defects by repair, replacement, or credit, at Tamarack Solar’s discretion.   

Refurbished Mounting Structures may be used to repair or replace the Mounting Structures 

 

Tamarack Solar shall have no liability for any injuries or damages to persons or property resulting from any cause, 

whatsoever, or any claims or demands brought against Tamarack Solar by Purchaser, any employee of Purchaser, client of 

Purchaser, end-user of the Product or other party, even if Tamarack Solar has been advised of the possibility of such claims 

or demands (collectively, “Third Party Claims”). This limitation applies to all materials provided by Tamarack Solar during 

and after the Warranty Period. 

 

 

 

 

Содержание UNI-PGRM 2019 Series

Страница 1: ...Horizontal Pole Mount Installation Manual UNI PGRM 2019 Edition V3 1 For models UNI PGRM 01 UNI PGRM 02 UNI PGRM 03 UNI PGRM 04 UNI PGRM 05 UNI PGRM 06 ...

Страница 2: ... the Horizontal Pole Mount can support installations in a wide range of locations Customer Support Tamarack Solar makes every effort to ensure your m ounting kit is easy to install If you need assistance at any point in your installation or have suggestions on how we can improve your experience call customer support at 1 800 819 7236 or email us at sales tamaracksolar com Tools Required Tools that...

Страница 3: ... 3102 000 Washer flat 5 16 SS 4 6 25 2501 015 Nut flange 5 16 SST 4 7 23 0100 033 GALV STEEL U BOLT 3 8 16 x 1 25 THRD LENGTH FOR 3 PIPE 5 OD LENGTH 1 8 25 3702 GLV Washer Flat HDG 2 9 25 3701 GLV WASHER LOCK 3 8 SPRING HDG 2 10 24 3716 GLV Nut Hex 3 8 16 HDG 2 ITEM PART NUMBER DESCRIPTION QTY 1 70 0400 000 rev C Cap 4 Pipe 1 2 23 0350 GLV GALV STEEL U BOLT 1 2 13 3 PIPE 2 3 51 0812 UBC rev A U BO...

Страница 4: ...es Assembly Step2 Install Top caps main beam to posts A Place Top Caps onto the posts don t tighten screws at this time B Place U Bolt clamps over the mounting holes on the top caps see next page C Place the main beam pipe onto the U Bolt clamps centered over the slots on each end of the top caps D Place 1 2 U bolts over the main beam pipe through the U Bolt clamps and top caps loosely attach with...

Страница 5: ...own below at one end B Place a level on the clamp to hold a horizontal position at this time Final angle adjustment will be done later C Tighten the nuts enough to hold the horizontal position as you will be placing modules onto them in next steps D Install the first mid clamp base 1 4 farther apart than the module width tighten to hold level to install the first module ...

Страница 6: ...e module and re tighten to hold position H Attach under module clamps to the module and end clamp base with the 5 16 18 x 7 8 bolt flange nut and washer as shown torque to 12ft Lbs NOTE The bolt must be up against the module frame I Install the next mid clamp base 1 4 wider than the module width tighten to hold position J Place next module onto the mid clamp base and center the module to overhang ...

Страница 7: ...e is ready then add the last end clamp base 1 4 wider than the module width place the module onto the clamps center the module move end clamp base up against the module attach last mid clamp top and under module clamps as done in previous steps Step 4 Set final angle A Loosen all the U Bolt nuts on the end and mid clamps just enough to allow the entire array to be rotated to the desired angle to t...

Страница 8: ...Installation Manual Horizontal Pole Mount 7 ...

Страница 9: ...heric conditions are excluded The Finish Warranty is VOID if the practices specified by AAMA 609 610 02 Cleaning and Maintenance for Architecturally Finished Aluminum www aamanet org are not followed by Purchaser for Tamarack Solar s aluminum based products The warranty covers the replacement cost of parts to repair the product to proper working condition Transportation and incidental costs associ...

Страница 10: ...und conditions We recommend consulting with a local engineer familiar with local regulations and build site requirements including soil conditions terrain and load criteria wind snow seismic All of these parameters may impact foundation requirements Foundation Hole Guidelines Nominal Pipe Size 6 Schedule 40 6 Above Grade Module Area Max Wind Speed Min Hole Diameter Min Hole Depth Min Pole Depth 70...