background image

TTP-46-MAN

Pole Mount - TTP Series

1

Installation Manual

For Models TTP-4, TTP-4HW, TTP-6, and TTP-6HW 

TTP-46-MAN 2022 Edition v2.3 

90392 

TTP-4  4 Module Top of Pole Mount

90408 

TTP-4HW  4 Module High Wind Top of Pole Mount

90415 

TTP-6  6 Module Top of Pole Mount

90422 

TTP-6HW  6 Module High Wind Top of Pole Mount

Содержание TTP Series

Страница 1: ...al For Models TTP 4 TTP 4HW TTP 6 and TTP 6HW TTP 46 MAN 2022 Edition v2 3 90392 TTP 4 4 Module Top of Pole Mount 90408 TTP 4HW 4 Module High Wind Top of Pole Mount 90415 TTP 6 6 Module Top of Pole Mount 90422 TTP 6HW 6 Module High Wind Top of Pole Mount ...

Страница 2: ...nly Tamarack parts or parts approved by Tamarack substituting parts may void any applicable warranty Comply with all applicable fire codes including but not limited to keeping walkways clear Ensure bare copper grounding wire does not contact aluminum and zinc plated steel components to prevent risk of galvanic corrosion If loose components or loose fasteners are found during periodic inspection ret...

Страница 3: ...д x 3Ͳ1 8Ͳinch 1 1 1 1 92016 Rectangular Tube 3x2 x 0 12 wall 2 2 92036 Rectangular Tube 3x2 x 0 188 wall 2 2 92017 Suport Pipe 2Ͳinch Sch 40 1 1 92037 Suport Pipe 2Ͳinch Sch 80 1 1 92018 Pivot Pipe 2 5Ͳinch Sch 40 1 1 92038 Pivot Pipe 2 5Ͳinch Sch 80 1 1 92020 Hex Bolt 1 2Ͳ13 x 3Ͳ1 2Ͳinch 4 4 4 4 92021 Flat Washer 1 2Ͳinch 4 4 4 4 92022 UͲBolt w Nuts for 2Ͳinch Pipe 8 8 8 8 93041 5Ͳfoot x 2Ͳinch ...

Страница 4: ... hole The pole length listed in the following tables are based on having the pole installed 2 3 inches from the bottom of the dug holes Use a brick concrete block tiles or other non organic solid material at the bottom of the hole to support the pole on allowing it to be raised above the bottom of the hole and allowing the concrete to fully encapsulate the pipe pole If using a thicker material be ...

Страница 5: ...8 6 40 13 28 5 50 12 38 100 4 40 11 80 3 70 11 10 4 90 12 30 4 20 11 60 5 70 13 10 4 90 12 30 120 5 00 12 40 4 30 11 70 5 60 13 00 5 80 12 20 6 60 14 00 5 60 13 00 140 5 70 13 10 4 80 12 20 6 30 13 70 5 40 12 80 7 40 14 80 6 30 13 70 100 4 90 12 77 4 20 12 07 5 40 13 27 4 70 12 57 6 40 14 27 5 40 13 27 120 5 60 13 47 4 80 12 67 6 30 14 17 5 40 13 27 7 40 15 27 6 30 14 17 140 6 30 14 17 5 40 13 27 ...

Страница 6: ...2 4 9 12 4 6 7 14 2 5 7 13 2 140 5 7 13 2 4 9 12 4 6 4 13 9 5 5 13 0 7 5 15 0 6 4 13 9 100 5 3 13 6 4 5 12 8 5 9 14 2 5 0 13 3 6 9 15 2 5 9 14 2 120 6 0 14 3 5 2 13 5 6 8 15 1 5 8 14 1 7 9 16 2 6 8 15 1 140 6 8 15 1 5 8 14 1 7 6 15 9 6 5 14 8 9 0 17 3 7 6 15 9 100 5 8 14 8 4 9 13 9 6 4 15 4 5 5 14 5 7 5 16 5 6 4 15 4 120 6 6 15 6 5 7 14 7 7 4 16 4 6 3 15 3 8 7 17 7 7 4 16 4 140 7 5 16 5 6 4 15 4 8...

Страница 7: ...e the array will be facing Loosely install the four 1 2 inch set screws in the threaded holes on the rear half of the Pole Cap Do not tighten at this time Securely tighten the two 3 4 bolts in the Pole Cap assembly but do not fully torque to spec until final assembly is complete Step Two Assemble H Frame Slide the 2 1 2 inch Pivot Pipe 2 7 8 O D through the holes on the side of the front half of t...

Страница 8: ...finger tight as the array angle will be readjusted in the final assembly Step Four Rail Support Pipes Connect two of the 2 inch Schedule 40 or 80 x 5 foot long Rail Support Pipes together using a 2 inch pipe coupling and thighten with two pipe wrenches Repeat with the remaining two 2 inch Schedule 40 or 80 x 5 foot long Rail Support Pipes and coupling HW versions if this mount are supplied with Sc...

Страница 9: ...over the splice butting the two rail ends together and repeat the Channel Nut installation process with the second Channel Nut and bolt 3 Repeat the processes in 1 and 2 above with the other three 85 inch and 42 5 inch rail sections and Splices Tighten all of the Splice bolts in the four completed 127 5 inch assemblies to 12 ft lbs Step Six Attach Module Mounting Rails The Module Mounting Rails sh...

Страница 10: ...odules A Ground Lug can be attached at any location desired on either one of the two Module Support Rails in each column Connect both ground lugs to the ground wire in the system according to local code Step Eight Mount PV Modules on Rails Before mounting the PV modules to the pole mount map out where you want the wiring junction boxes and output cables on the backs of the modules to be located To...

Страница 11: ...to 144 inch pounds 12 foot pounds to fully secure the module Install the third module in the column on TTP 6 or TTP 6HW in the same manner On the top edge of the last module of the first column install the two Module Clamps so that the sides with the two stainless steel pins are facing in toward the module frame and the clamp is tight up against the module frame Tighten the two end clamp bolts to ...

Отзывы: