Faults and Troubleshooting
P/N 1149-084775
Tally Printer Corp.
19
Supplement to Chapter 3: Faults and Troubleshooting
In the T6215 Maintenance Manual the fault message:
Hammer Voltage
has been replaced, in the T6218, with:
Hammer Voltage 1
There is a new fault message for the T6218. It is:
Hammer Voltage 2
Explanation:
A high resistance coil fault has likely occurred in one or more of the
hammer coils.
Note: This fault message will have been preceded by printing slow-down
attempts associated with On-The-Fly thermal monitoring of hammer
bank temperature.
Corrective Action:
Check the hammer bank for defective hammer coils.
Confirm that hammer drive board is functioning properly.