Tally Dascom DT-210/230 Programming Guide V1.1
- 51 -
ESC c 5 n
[Type]
Panel button
[Function]
Enable/disable panel buttons
[Format]
ASCII
ESC c 5 n
Hex
1B 63 35 n
Decimal
27 99 53 n
[Range]
0 ≤ n ≤ 255
[Default]
n = 0
[Description]
• Enables or disables the panel buttons.
• When the LSB of n is 0, the panel buttons are enabled.
• When the LSB of n is 1, the panel buttons are disabled.
[Note]
• This command affects the FEED button.
• The FEED button is disabled regardless of the settings with this command, when the
cover is open.
GS g 2 m nL nH
[Function]
Transmit maintenance counter
[Format]
ASCII
GS g 2 m nL nH
Hex
1D 67 32 m nL nH
Decimal
29 103 50 m nL nH
[Range]
m = 0
(nL + nH × 256) = 20, 21, 50, 70, 148, 149, 178, 198
(nL = 20, 21, 50, 70, 148, 149, 178, 198, nH = 0)
[Description]
Transmits the value of the maintenance counter specified by (nL + nH × 256).
(nL + nH × 256)
Maintenance counter [Units]
Type of counter
Hex
Decimal
14
20
Number of lines fed. [Lines]
Resettable
(can be reset)
15
21
Number of head energization. [Times]
32
50
Number of auto cutter operations. [Times].
46
70
Duration of printer operation. [Hours]
94
148
Number of lines fed. [Lines]
Cumulative
95
149
Number of head energization. [Times]
B2
178
Number of auto cutter operations. [Times].
C6
198
Duration of printer operation. [Hours].
[Note]
• The maintenance counter values are measurements; therefore, their values will be
affected by the timing of errors and how and when the power is turned off.
• When this command is transmitted, do not transmit the subsequent data until the
status is received.