32 ≤ d ≤ 255
k = (nL + nH × 256)
The entire capacity size = 1KB.
[Description]
Stores the data (d1...dk) in the area from (a1 + a2 × 256 + a3 × 65536 + a4 × 16777216)
to (nL + nH × 256) bytes in the NV user memory.
[Note]
• Frequent write command executions by an NV memory write command may damage
the NV memory. Therefore, it is recommended to limit writing the commands into the
NV memory to less than 10 times a day.
• If the power is turned off or the printer is reset via an interface while this command is
being executed, the printer may go into an abnormal condition. Be careful not to turn
the power off or let the printer be reset via an interface while this command is being
executed.
• While processing this command, the printer may become BUSY while writing the data
to the NV memory and stops receiving data. Therefore, be sure not to transmit data,
including the real-time commands while the printer is BUSY.
FS g 2 m a1 a2 a3 a4 nL nH [obsolete command]
[Function]
Read from NV user memory
[Format]
ASCII
FS g
2 m a1 a2 a3 a4 nL nH
Hex
1C 67
32 m a1 a2 a3 a4 nL nH
Decimal
28 103 50 m a1 a2 a3 a4 nL nH
[Range]
m = 0
0 ≤(a1 + a2×256 + a3×65536 + a4×16777216) ≤ 1023
(0 ≤ a1 ≤ 255, 0 ≤ a2 ≤ 3, a3 = 0, a4 = 0)
1 ≤ (nL + nH × 256) ≤ 80 (1 ≤ nL ≤ 80, nH = 0)
[Description]
Transmits the data in the area from (a1 + a2 × 256 + a3 × 65536 + a4 × 16777216) to (nL
+ nH × 256) bytes in the NV user memory.
[Note]
When this command is transmitted, do not transmit the subsequent data until the
status is received.
GS g 0 m nL nH
[Function]
Initialize maintenance counter
[Format]
ASCII
GS
g 0 m nL nH
Hex
1D
67 30 m nL nH
Decimal
29
103 48 m nL nH
[Range]
m = 0
(nL + nH × 256) = 20, 21, 50, 70
[Description]
Set the resettable maintenance counter specified by (nL + nH × 256) to 0.