<Function 5>GS ( E pL pH fn [a1 n1L n1H]...[ak nkL nkH] (fn = 5)
[Function]
Set the customized setting values
[Format]
ASCII
GS ( E pL pH fn [a1 n1L n1H] ... [ak nkL nkH]
Hex
1D 28 45 pL pH fn [a1 n1L n1H] ... [ak nkL nkH]
Decimal
29 40 69 pL pH fn [a1 n1L n1H] ... [ak nkL nkH]
[Range]
4≤(pL + pH×256)≤65533 (0 ≤ pL ≤ 255, 0 ≤ pH ≤ 255)
fn = 5; a = 5, 6, 97, 116, 118
0≤(nL + nH×256) ≤6, (nL + nH×256) = 100, 65530≤(nL+nH×256)≤65535
(0≤nL≤6, nH=0, nL= 100, nH=0, 250 ≤ nL ≤ 255, nH = 255) [when a = 5]
1 ≤ (nL + nH × 256) ≤ 9 (1 ≤ nL ≤ 9, nH = 0) [when a = 6]
(nL + nH × 256) = 1, 2, 4, 128 (nL = 1, 2, 4, 128, nH = 0) [when a = 97]
(nL + nH × 256) = 1, 257 (nL = 1, nH = 0, 1) [when a = 116]
(nL + nH × 256) = 70, 85 (nL = 70, 85, nH = 0) [when a = 118]
[Default (upon
shipment)]
(nL + nH × 256) = 100 (nL = 100, nH = 0) [when a = 5]
(nL + nH × 256) = 9 (nL = 9, nH = 0) [when a = 6]
(nL + nH × 256) = 128 (nL = 128, nH = 0) [when a = 97]
(nL + nH × 256) = 1 (nL = 1, nH = 0) [when a = 116]
(nL + nH × 256) = 85 (nL = 85, nH = 0) [when a = 118]
[Description]
• Sets the customized value specified by a to the values specified by (nL + nH × 256).
a
Type of customized value
5
Print density
6
Print speed
97
Number of division of thermal head energization
116 Print control (single-color or two-color)
118 Black-color density in two-color printing
• Print density setting (a = 5)
(nL + nH × 256) Print density
100
Density level depending on the DIP switch settings
65530
Print density level 1.
light
65531
Print density level 2
|
65532
Print density level 3
|
65533
Print density level 4
|
65534
Print density level 5
|
65535
Print density level 6
|
0
Print density level 7
standard
1
Print density level 8
|
2
Print density level 9
|
3
Print density level 10
|
4
Print density level 11
|
5
Print density level 12
|
6
Print density level 13
dark