Command
Function
*12* …[
6 digits]*
Program the phone Identification number
*49*
Suppress automatic transmission of the phone ID
(default)
*50*
Automatically transmit the phone ID when guard station answers a call
1
*104*
Transmit the phone ID when the phone answers a call
2
(default)
*105*
Suppress transmission of the phone ID when the phone answers a call
1
Required for use with Talk-A-Lert base-station software
2
Required for use with Talk-A-Lert polling software
Auxiliary Device Automatic Activation Codes
All ETP-500 Series Analog Call Stations have two (2) auxiliary outputs, and a single auxiliary input is
available on ETP-500 Series Analog Call Stations by request. The following codes allow you to control
the function of the auxiliary output leads (also see Operation Codes, p.9).
Command
Function
*24* …[0 –
6]*
Sets "ON" time for Auxiliary Output #1 (incoming calls only)
*27* …[0 –
6]*
Sets "ON" time for Auxiliary Output #2 (incoming calls only)
Value
"ON" Time
0
Continuously ON for duration of call
1
1 Second
(default)
2
3 Seconds
3
5 Seconds
4
10 Seconds
5
30 Seconds
6
60 Seconds
Note: Timer is only for calls made TO the call station. If an AUX is
activated by a call FROM a call station, the AUX contacts will remain
closed for the duration of the call.
*87*
Sets Button #1 to activate Output #1
*88*
Cancels *87* command
(default)
*56*
Sets Button #1 to activate Output #2
*57*
Cancels *56* command
(default)
*90*
Sets Button #2 to activate Output #1
*91*
Cancels *90* command
(default)
*92*
Sets Button #2 to activate Output #2
*93*
Cancels *92* command
(default)
*64*
Make Auxiliary Output #1 drive an additional LED
*65*
Cancels *64* command
(default)
On models with keypads, the button that activates the keypad cannot be programmed to
automatically activate the auxiliary outputs.