  Rev. 6/28/2017

 

 

Copyright 2017 Talk-A-Phone Co.

 

• 7530 North Natchez Avenue • Niles, Illinois 60714 • Phone 773.539.1100 • [email protected] • www.talkaphone.com. 

 

 

All prices and specifications are subject to change without notice. Talk-A-Phone, Talkaphone, Scream Alert, WEBS, and WEBS Contact are registered trademarks of Talk-A-
Phone Co.  All rights reserved.  All other trademarks mentioned in this document or website are the property of their respective owners and does not imply or indicate any 
approval, endorsement, sponsorship, or affiliation with such owners unless such approval, endorsement, sponsorship, or affiliation is expressly indicated. 

For Remote Mode or Day/Night Mode 
Three (3) dedicated POTS/PSTN lines (i.e. analog telephone lines or analog PBX lines). 

If connected to a PBX, the extension(s) must provide: 
 

1.  At least 24 Volts at 20 mA off-hook (no current is drawn on-hook 

 

2.  Either a disconnect pulse (voltage drop at end of call) or 30-seconds or silence after hang-up 

(no re-order or howler feature) 

 

If connected to a POTS/PSTN line, there must be no special features, such as hook-flash, call-
waiting, auto-redial when busy or voicemail. If the telephone company has activated any such 
features, contact them to have these features turned off. 

IV. 

Installation 

1. 

Remove the 

AOR-8 / AOR-16 

unit from its packaging carton and inspect for any possible 

damage.  If the unit is damaged or if any components are missing, please contact your 
Talkaphone distributor immediately.  Do not discard any hardware or packaging prior to 
checking for all included components listed above, and the unit is installed and functioning 
correctly. 

2. 

Remove the three (3) Phillips screws from the right side of the unit which secure the hinged 
front cover shut. 

3. 

Remove the packaged front cover door handle from the telephone compartment and install to 
the outside surface of the unit using the provided screws. 

4. 

Carefully open the hinged front cover taking care there are no loose items which may have 
shifted during transportation. 

5. 

The 

AOR-8 / AOR-16 

unit may be either surface mounted or flush mounted to a wall.  

 

NOTE:

 For flush mounting units, 

AOR-8 / AOR-16 

units should be ordered with the 

available AOR-TR16 Flush Mount Trim Ring (sold separately). 

 
 

NOTE:

 Conduit knockouts exist on the rear, top, and bottom sides of the enclosure for 

access to power and communication lines. Determine the method of bringing in these 
power and communication lines 

before

 mounting the enclosure. 

 
 

NOTE:

 Whenever possible, it is best to keep the maximum clearance possible between 

analog phone lines and alternating current. Running phone lines too close to hot VAC 
lines will produce undesired effects on the phone line. 

 

 
6. 

For surface mounting the unit directly to the surface of an interior wall: 
The 

AOR-8 / AOR-16 

unit has six (4) surface mounting keyholes. 

7. 

For flush mounting the unit:  

 

The 

AOR-8 / AOR-16 

unit has eight (8) 7/32 [in] knockouts located on the top, bottom and 

sides which can be used for either mounting the unit within a wall or to fasten the available 

AOR-TR16

 Flush Mount Trim Ring. This trim ring may be installed in contact with the closed 

cover without inhibiting the functionality of the hinge. 

Содержание AOR-8

Страница 1: ...es Analog Call Stations It is recommended that this instruction set be read completely prior to the start of any installation II Contents Please ensure receipt of each of the included AOR 8 AOR 16 com...

Страница 2: ...distributor immediately Do not discard any hardware or packaging prior to checking for all included components listed above and the unit is installed and functioning correctly 2 Remove the three 3 Phi...

Страница 3: ...rnal compartment The Black wire is a common negative and needs to be connected to both the strobe and siren negative terminals The Red White wire gets connected to the Positive terminal of the strobe...

Страница 4: ...e In Remote Mode pressing the button on any of the Talkaphone Analog Call Stations will cause them to access a phone line to dial out For this configuration connect an outside phone s line to the Telc...

Страница 5: ...enough rings for the person answering the phone to pick up WARNING The other device sharing the line should never be emergency equipment of any kind including another bank of the AOR 16 19 Once the c...

Страница 6: ...uccessfully 2 Beeps Error s detected If you hear two beeps enter the code again If you hear two beeps a second time hang up and try again Remote Mode In Remote Mode if a standard telephone company pho...

Страница 7: ...details on programming the Talkaphone Analog Call Stations refer to the Installation Operation Manual for Emergency Information Phones Note if the Consolidator is in Remote Mode or Day Night Mode and...

Страница 8: ...seize the line on behalf of the Analog Call Station When a call comes in to the AOR 8 AOR 16 unit an LED will light indicating which Analog Call Station is calling in If a call is already being answe...

Страница 9: ...0 feet 18 AWG 1 801 3 000 feet 16 AWG 3001 5 000 feet 14 AWG Distance from AOR 8 AOR 16 Unit to Local Phone Recommended Wire Gauges 0 1000 feet 24 AWG 1001 1500 feet 22 AWG 1501 2000 feet 20 AWG 2001...

Страница 10: ...epartment 4 There isn t enough power on the line see Technical Requirements page 3 5 You may have accidentally plugged a PBX line or phone company line into the Local port If so contact Talkaphone tec...

Отзывы: