This sensor is only suitable for indoor application.
This sensor consists of a transmitter that emits infrared beam and a
receiver that receives it.
As illustrated below, the infrared beam emitted from the transmitter
is reflected in the direction of incidence and then enters the receiver.
A protection loop is formed in the route of the transmitter
reflector
receiver.
Whenever this loop is interrupted (if any object should interrupt the
infrared beam), it is detected and an alarm is initiated.
Installation of sensor unit
PHOTOELECTRIC BEAM SENSOR
PR-5B
Instruction Manual
Thank you for purchasing the TAKEX product.
This sensor will provide long and dependable service when properly installed.
Please read this Instruction Manual carefully for correct and effective use.
Please note : This sensor is designed to detect intrusion and to initiate an alarm ; it is not a burglary-preventing device.
Sensor
16.5' or less
(5m or less)
Receiver
Transmitter
Alarm is initiated when
the beam is interrupted.
Reflector
0.79" (
φ
0.2m)
Size of wire used
AWG 22 (Dia. 0.65mm)
AWG 20 (Dia. 0.8mm)
AWG 18 (Dia. 1.0mm)
up to 1000' (300m)
up to 1800' (550m)
up to 2800' (850m)
up to 5000' (1500m)
up to 9000' (2750m)
up to 13500' (4250m)
Input voltage
DC 12V
DC 24V
To obtain the maximum length of wiring when two or more
sensors are connected, divide the above figures by the
number of units used.
Signal line can be wired up to 3,300ft (1,000m) using AWG
22 telephone wire.
Note 1.
2.
1
PRODUCT DESCRIPTION
Mouting hole
Mounting hole
Infrared beam filter
Knockout
Case
Terminal cover
(Terminals inside)
Operation LED
Lights when an alarm is initiated.
(A red light is seen through filter.)
Dry contact relay output IC
Contact capacity : 30V AC/DC,
up to 0.5A
POWER
DC10.5
〜
26V
ALARM
COM.
N.O.
N.C.
Reflector
1
Reflector mounting
plate
1
Double-faced
adhesive sheet
2
Accessory
●
Example 1
●
Example 2
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
Power source
for sensor
Power source
for sensor
Signal input
Signal input
(1ch.)
Signal input
(2ch.)
Control panel
Control panel
Sensor
Sensor
LED ON
LED OFF
Tentative
center
Tentative
center
Reflector
Actual center
(installation
position)
When 1 input to plural
sensors are installed.
When plural inputs to plural
sensors are installed.
Unnecessary when additional
sensors are installed.
Fig. 1
Fig. 2
Knockout
Remove terminal cover
(Terminals inside)
① ② ③ ④ ⑤
+
−
+
−
}
}
}
}
When a magnetic switch or the like is used in the circuit, insert it in the section .
For more details, refer to instruction manual for control panel.
The dotted lines indicate connections for additional sensors installed.
Remove the terminal cover. Connect the wires with the corresponding terminals correctly as
instructed on the back side of the sensor. Break the knockout if necessary.
Sensor mounting
screw (M3
×
16)
2
Reflector mounting
screw (M4
×
16)
2
②
Terminal arrangement
①
Remove
③
Wiring distance between sensor and control panel
④
Examples of connections
⑤
Wiring connections
Note 1.
2.
3
WIRING
4
4-1
Installation of reflector
4-2
INSTALLATION
2
PARTS DESCRIPTION
Detection activation of this sensor is off-delay (detection time + approx. 1.5 sec.).
For that reason, check protection coverage as the following procedure.
1. Hold the reflector against the wall over the "X" mark previously made and check the operation LED on the PR-5B.
2. If the operation LED lights up, check the position where it goes off while moving reflector slowly vertically and horizontally by sliding for positioning
tentative center of coverage. * (Fig 1 .) Move the reflector as slowly as possible because it takes approx. 1.5 sec at least till operation LED goes off
though the reflector comes in coverage. If moving is too fast, the PR-5B will not have time to rest and operation LED will not go off.
3. Check 4 positions (in every directions) where operation LED lights up while moving reflector slowly outward from the center.
The center of these 4 positions is an actual
coverage center where reflector should be
installed. * (Fig 2.) LED lights up at real time
when reflector moves out of coverage (When an
alarm triggers.)
Important : A common mistake is made by holding
the reflector in the hand in the air, when
trying to make the PR-5B set up.
This is extremely difficult to achieve.
PLEASE DO NOT ATTEMPT TO DO
THIS.
The following instructions will ensure a successful set up.
1. Select appropriate installation position and determine the best mounting height for application. (PR-5B shall face the direction to be protected.)
2. Measure the distance from the floor to where the center of the PR-5B main unit will be located. Mark a small "X" on the wall at that point. (Measure and
mark the same distance from the floor on the opposite wall where the reflector will be mounted. Ensure that both walls
are reasonably parallel to each other.)
3. Connect the 10.5-26VDC power input and alarm output wires to the appropriate terminal connectors at the rear of the PR-5B.
4. Fix the PR-5B securely to the wall using the "X" mark already made as the center reference on the wall.
Ⅰ
Ⅱ
infrared beam
infrared beam