COMPONENTS
1
CONNECTIONS
4
SAFETY CAUTIONS
2
OPERATING CAUTIONS
3
Wafer mapping sensor
●
Input/output circuit
Capacitor ground
DC12〜24V
DC5V
Light emission inhibit input
Output inhibit input
CH and error outputs
0V
※ For a noise prevention, a capacitor is installed between
the 0V power supply and the sensor's aluminum case.
1/4
Internal circuit
The following cautions must be strictly observed in order to ensure safety.
1. This product is not designed for the use in safety systems which detect the
presence of human body. Do not use this product either directly or indirectly
for applications.
2. Do not use this product when its case or cable is in a damaged condition.
3. Do not attempt to disassemble, repair, or modify this product.
4. Do not use this product in environments where flammable, explosive, or
corrosive gases are present.
5. Do not use this product in environments where the product could be exposed
to oils and chemicals.
6. Do not use this product in water, in rain, or outdoors.
7. Do not use this product under conditions or in environments which exceed
the product ratings.
8. Do not use this product in locations which are exposed to direct sunlight.
9. Do not use this product in locations which receive direct vibrations or impact
shocks.
10. Do not wipe this product with thinner, alcohol, or any other organic solvent.
11. Perform daily inspections and periodic inspections (approximately every week)
together with the prescribed maintenance/inspection procedures to verify
that the product is functioning normally.
12. This product must be discarded of as industrial waste.
(refer to dimensions for shapes and sizes of each component.)
T A K E N A K A E L E C T R O N I C
I N D U S T R I A L C O . , L T D .
Head office, factory
Telephone
FAX
: 20-1 Narano -cho, Shinomiya, Yamashina -ku,
: Kyoto 607 -8032 , Japan
: +81 - 75- 581 - 7111
: +81 - 75- 581 - 7118
Instruction Manual
1. Placing high-voltage cables, power cables, and the product wiring together in a
single conduit or duct could cause induction-related malfunctions and possible
equipment damage. Make sure to separate these cables when wiring.
2. Avoid applying an excessive force to the cables.
3. Always install an FG (frame ground terminal) when using a commercially available
switching regulator.
4. Because detection is enabled 1sec after the product's power is turned ON,
always wait 1sec after power ON before attempting to the use the product.
If the load and the product are connected to different power supplies, be sure
to turn the product's power ON first.
5. Because an output pulse may be generated at power OFF, we recommend that
the load or the load line's power be turned OFF first.
6. Do not use in applications where the power is turned ON and OFF in a
continuous manner.
7. For the operation power supply, limit the current (2A) in accordance with the
conductor size which is connected to the connector.
8. Screws should not be screwed-in 8 mm or more into the sensor when mounting.
Choose a proper length of screws according to the thickness of the fixing body.
The sensor may be damaged if inappropriately long screws are used.
Comb
Switch cover
CH1 (1st beam axis) mark
M4x8 screw
※
Connector Fujitsu
FCN-361J040-AU
Fixing plate for packing
(Remove before using sensor)
※(The M4×8 screws are used to fix
the fixing plate. Do not use these screws
to mount the product.)
●
Pin configuration diagram
Each signal is passed from the sensor through the cable, and converted
from serial to parallel in the connector. Three connector pins are used
each for the power cable's +24V and 0V.
to allow the consumption and output current,
connect the three in parallel.
When using the *1 and *2 light emission inhibit input and output inhibit
input, connect the return wire to the connector's 0V (B8, B13, B14).
The two light emissions inhibit input and output inhibit output wires are
connected in the sensor.
A Fujitsu FCN-361J040-AU connector is used.
Confirm that the connector is correctly connected before turning the
power ON.
Do not used non-specified pin numbers for junction wiring, etc.
+24V
+24V
+24V
0V
0V
0V
*1
*1
*2
*2
CH1
CH2
CH3
Ch4
Ch5
Ch6
Ch7
CH8
CH9
CH10
CH11
CH12
CH13
Ch14
CH15
CH16
Ch17
CH18
CH19
CH20
CH21
CH22
CH23
CH24
CH25
CH26 *4
B7
B10
B11
B8
B13
B14
B16
B17
B19
B20
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
A13
A14
A15
A16
A17
A18
A19
A20
B1
B2
B3
B4
B5
B6
B9
Sensor
Name
Connector number
*3
*1:Light emission inhibit input
*2:Output inhibit input
*3:Error output
*4:ASW-SG86F
External wiring and connector number
ASW-SG85F/ASW -SG86F
Internal circuit