Special Loads
154
Special Loads
This section explains about loads with reverse current and pulse current loads as special loads.
Loads with Reverse Current
The dummy resistor will shunt the reverse current and prevent the output voltage from rising.
Reverse-Current Absorption by Dummy Resistor
Also, when the pulse reverse current flows and the average current value is in the supply direction, the voltage can be
stabilized by connecting capacitor (1000μF to 10000μF) in parallel.
For Pulse Reverse Current
Reverse Current I
R
Power Supply
+
-
V
O
Dummy
Resistor
R
S
Load
When
This machine does not have functions to stabilize the output voltage against reverse current
from loads. If the maximum sink current is exceeded, the output voltage will rise above the
rated value and burn-out the internal circuits.
Please do not apply voltages to the output terminal, which exceed the power supply’s rating.
Please do not apply voltages to the output terminal which exceed the power supply’s
rated output voltage.
Please use specialized break units etc. to suppress the generation of over voltage
when there is regenerative reverse current in the motor inverter load.
I
O
Power Supply
+
-
C
Load
+
I
O
0A
+
-
Reverse Current
-
!
CAUTION
!
CAUTION
Содержание HX-S-G4 Series
Страница 157: ...Special Loads 157 This page is blank...
Страница 161: ...Maintenance 161 This page is blank...
Страница 197: ...Specifications 197 External Diagrams 1 HX S 030 200G4 F I...
Страница 198: ...Specifications 198 2 HX S 030 400G4 F I...
Страница 199: ...Specifications 199 3 HX S 060 100G4 F I...
Страница 200: ...Specifications 200 4 HX S 060 200G4 F I...
Страница 201: ...Specifications 201 5 HX S 0500 12G4 F I...
Страница 202: ...Specifications 202 6 HX S 0500 24G4 F I...
Страница 203: ...Specifications 203 7 HX S 01000 6G4 F I...
Страница 204: ...Specifications 204 8 HX S 01000 12G4 F I...