Basic Usage
28
Operating as Constant Voltage Power Supply
Please verify that the settings for Over Voltage Protection
(OVP) circuit (page 41) and Over Current Protection (OCP)
circuit (page 43) are in effect.
Turn the POWER switch ON to startup the power supply.
The voltage measurement value will be displayed in the Number
Display (voltage) and the current measurement value will be
displayed in the Number Display (current). The lamp “V” and “A”
will light.
(If parameters for FUNCTION settings item 52 is set to 1,
PRESET value will be displayed)
Press the PRESET key
PRESET lamp will light.
Press the PRESET key again if you wish to discontinue and
return to the measurement display mode.
The voltage PRESET value will be displayed in the Number
Display (voltage) and the current limit PRESET value will be
displayed in the Number Display (current).
Turn the VOLTAGE dial to adjust the Constant Voltage Set Value
(Turn the dial right to raise or left to lower the set value.)
If the parameter for FUNCTION item 50 is set to 0, press the PRESET
key again. The output voltage will be updated once the PRESET mode
has been exited.
If the parameter for FUNCTION item 50 is set to 1, promptly change the
set value using the VOLTAGE dial.
Turn the CURRENT dial to adjust the Current Limit Value
Set a value greater than the required load current.
(Turn the dial right to raise or left to lower the set value.)
Continued on next page
Press the VOLTAGE dial to display the current number
position. The selected number will be brightened. Press to
change position.
If all 4 places are brightened, numbers will change from
the lowest place.
When POWER is turned OFF for the top or
bottom Number Display, the Number Display
will be displayed in the same manner when
POWER is turned on again.
* The "kW" lamp will light when the power is
displayed.
MEMO
If the current limit value is set to a value lower than the
required load current, the current will be restricted and
the constant current will be used. (CC lamp lights)
MEMO
MEMO
* The above is the display cases (HX-S-030-200G2)
。
* The above is the display cases (HX-S-030-200G2)
。
Содержание HX-S-01000-12G2
Страница 165: ...Special Loads 165 This page is blank...
Страница 169: ...Maintenance 169 This page is blank...
Страница 211: ...Specifications 211 External Diagrams 1 HX S 030 200G2 F I...
Страница 212: ...Specifications 212 2 HX S 030 400G2 F I...
Страница 213: ...Specifications 213 3 HX S 060 100G2 F I...
Страница 214: ...Specifications 214 4 HX S 060 200G2 F I...
Страница 215: ...Specifications 215 5 HX S 0120 50G2 F I...
Страница 216: ...Specifications 216 6 HX S 0120 100G2 F I...
Страница 217: ...Specifications 217 7 HX S 0400 15G2 F I...
Страница 218: ...Specifications 218 8 HX S 0400 30G2 F I...
Страница 219: ...Specifications 219 9 HX S 0500 12G2 F I...
Страница 220: ...Specifications 220 10 HX S 0500 24G2 F I...
Страница 221: ...Specifications 221 11 HX S 01000 6G2 F I...
Страница 222: ...Specifications 222 12 HX S 01000 12G2 F I...
Страница 223: ...Specifications 223...