background image

 

Using in Series/Parallel Operation 

 

 

 

131 

Series Operation 

A series connection of two HX-S-G2 power supply outputs can be used to double the output voltage. 
Further, Master-Slave Series Operation, the controlling of the output with a single Master, is available. 

 
 

 
 
 

 

 

Connection 

Connect as shown in the diagram below. 

 

Load

+

Twisted

Twisted

Insulation Control 

Connector

Series Operation Control Connector

External Control 

Connector

1

16

1

13

14

26

(slave Unit)

(Master Unit)

 

 

 

Series operation is possible only between HX-S-G2 whose rated output voltage and rated output 
current are the same. 

 

Connecting device models that are different in power capacity will result in breakdown. 

 

Turn all series connected HX-S-G2 Series’ input power (POWER switch) ON. 

 

Please calibrate the output voltage for the Slave before use. 

 

FUNCTION Settings items, when operating in Slave, are restricted. 

 

When  operating  in  Slave,  the  only  valid  keys  during  an  alarm  reset  are  the  RESET,  OVP/OCP, 
FUNC., and LOCAL keys. 

 

The indication on the front display during series operation shows the outputs of the Master unit and 
the Slave unit respectively. 
(When the output voltage is 60V, both the Master unit and the Slave unit will be 30.00V.) 

   

CAUTION

 

HX 1000V type does not correspond to the series operation. Please do not connected in series 
with the series operation absolutely. 

 

Prohibition

Содержание HX-S-01000-12G2

Страница 1: ...ant Current DC Power Supply HX S G2 series Instruction Manual HX S 030 200G2 HX S 030 400G2 HX S 060 100G2 HX S 060 200G2 HX S 0120 50G2 HX S 0120 100G2 HX S 0400 15G2 HX S 0400 30G2 HX S 0500 12G2 HX...

Страница 2: ...Saving in Memory 47 Loading from Memory 47 Panel Memory Savable Settings 48 Startup Mode Selection 49 Variable Slew Rate 50 Sequential ON OFF 52 Sequential ON OFF Connection 52 Using the Sequential F...

Страница 3: ...ation of Output Voltage Settings 170 Offset Full Scale Calibration of Output Current Settings 172 Offset Full Scale Calibration of Output Voltage with External Analog Input 174 Output Voltage Control...

Страница 4: ...ymbol and improper use or handling of the product may result in injury or property damage Items that must be observed are classified into the following marks This mark indicates items that are Prohibi...

Страница 5: ...to carry the this equipment Turn off the input power switch POWER and remove all cables from the main body beforehand Hold the bottom surface during carrying Do not hold the handles on both sides The...

Страница 6: ...V Output Voltage V Output Voltage V Output Voltage V Output Voltage V Output Current A Output Current A Output Current A Output Current A Output Current A Features Improved Parallel Operation New Mast...

Страница 7: ...rformed with the front panel dials Analog Monitor Outputs the output voltage and output current with 0 10V DC Not suited for monitoring transient voltage current waveforms Status Alarm Output Outputs...

Страница 8: ...tting status with keys A B and C Also depending on the Function item setting this can be used to select One Action or Two Action loading method LOCK LOCK Key Locks panel from use Lights when Lock has...

Страница 9: ...as been transferred to an external computer etc being accessed via serial interface Number Display Voltage Displays the output voltage and the output power When setting functions with the Function key...

Страница 10: ...r for parallel operations TERMINATION Termination Resistor ON OFF Switch When controlling one unit of this product via serial port please set the termination toggle switch to ON When using 2 or more p...

Страница 11: ...S 0500 24 HX S 0400 30 HX S 01000 6 HX S 01000 12 DC OUTPUT terminal Always use crimp terminals please firmly tighten the screws Please Once connected sure to attach the output terminal cover REMOTE...

Страница 12: ...r 400V 500V and 1000V type 2 M5 x 12mm screws are attached to the DC OUTPUT terminal on the rear panel at the time of shipment 10 Output Terminal Cover for 30 200 60V and 120V type 1 set Two same shap...

Страница 13: ...re attached to the DC OUTPUT terminal on the rear panel at the time of shipment 10 Output Terminal Cover for 30 200 60V and 120V type 1 set Two same shape Output Terminal Covers A support for mounting...

Страница 14: ...see below for proper placement How to place Mandatory Use only in areas with a room temperature of 0 50 humidity of 20 90 RH and which is absent of any corrosive gases Prohibited This power supply us...

Страница 15: ...ion and the delta connection either will be available Set circuit breaker between feeding device and this equipment Connect the circuit breaker to the feeding device and the equipment The input power...

Страница 16: ...30G2 21mm2 AWG4 more 2 Tighten L1 L2 and L3 cable to the terminal block with screws 3 Mount the terminal cover to the terminal block with the appended M3 screw 1 Tighten the grounding cable to the pr...

Страница 17: ...one at the load end Wiring material Do wiring material twisting Route as close as much as possible M12 Bolt M12 Crimping terminal Protective tube Insulation lock Output terminal cover 400V 500V 1000V...

Страница 18: ...or load currents For selecting wires refer to Appendix 4 Load Current vs Recommended Cross Section Area page237 Mandatory Attach crimp style terminals to wires and securely fasten If insecurely fasten...

Страница 19: ...r both covers are identical in shape Insert the supporter for attaching into the center part of the inside of the output terminal cover and fix it in place by screwing an M3x6mm from outside 2 Connect...

Страница 20: ...attaching cover has been attached on the left side grooves of the output terminal 5 Fix the other output terminal cover on the right side grooves of the output terminal 6 Fasten the output terminal c...

Страница 21: ...over by joining the wire bands together using four M3 x 6mm screws 2 The upper and lower output terminal cover can be checked from the front of the cover Please refer to the following 3 Snap the termi...

Страница 22: ...Preparation and Connection 22 4 To finish the installation use the 2 M3 x 6mm screws to fix the top and bottom terminal covers together M3x6mm Screw...

Страница 23: ...ntical in shape Insert the supporter for attaching into the center part of the inside of the output terminal cover and fix it in place by screwing an M3x6mm from outside 2 Fix the output terminal cove...

Страница 24: ...Preparation and Connection 24 4 Fasten the output terminal covers with an M3X6mm screw 5 Attaching the output terminal cover is completed...

Страница 25: ...output capacity if you hold down the FUNC key for more than 2 seconds to approve the current total output capacity it returns to the measurement display mode Models HX S 030 200G2 HX S 060 100G2 HX S...

Страница 26: ...0 0V 0 0V 0 0V Constant Current Set Value 12 60A 25 20A 6 300A 12 60A Over Voltage Protection OVP Set Value 550 0V 550 0V 1100V 1100V Over Current Protection OCP 13 20A 26 40A 6 600A 13 20A Settings...

Страница 27: ...and C once the Number Display lights up Each setting returns to the factory setting Backing Up Settings This power supply saves all settings in non volatile memory EEPROM just before the POWER switch...

Страница 28: ...wer the set value If the parameter for FUNCTION item 50 is set to 0 press the PRESET key again The output voltage will be updated once the PRESET mode has been exited If the parameter for FUNCTION ite...

Страница 29: ...settings and returns to the measurement display mode Press the OUTPUT key Outputs with the set settings The OUTPUT and CV lamps will light While the PRESET lamp is lit all other keys not mentioned in...

Страница 30: ...ht to raise or left to lower the set value If the parameter for FUNCTION item 50 is set to 0 press the PRESET key again The output current will be updated once the PRESET mode has been exited If the p...

Страница 31: ...settings and returns to the measurement display Press the OUTPUT key Outputs with the set settings The OUTPUT and the CC lamp will light While the PRESET lamp is lit all other keys not mentioned in t...

Страница 32: ...ile using remote sensing do not switch output lines using switches etc Doing so may lead to damaging the power supply Because the output terminal s voltage is detected by the OVP circuit please set th...

Страница 33: ...g Procedures Press The Function FUNC key The FUNC lamp will light The Setting Item Number will be displayed in the Number Display voltage and the parameter will be displayed in the Number Display curr...

Страница 34: ...12 00A S HX S 01000 12 0 01A S 24 00A S Maximum of parameter range When Parallel Connection Maximum Output Current x 2 s This function can be set for full featured type model name with F only 5 CC Sle...

Страница 35: ...tage Monitor Output Full Scale Not displayed 34 Current Monitor Output Offset Not displayed 35 Current Monitor Output Full Scale Not displayed 36 Not displayed 37 Voltage offset when series slave Not...

Страница 36: ...le to use HX S 01000 G2 1 External Voltage 0 10V 2 External Resistance 0 10k A 3 External Resistance 0 10k B 4 External Resistance 0 10k C 71 CC Control EXT R V PANEL Settings 0 Front Panel 0 Front Pa...

Страница 37: ...6 Over Heating Protection OHP B05 Over Voltage Protection OVP B04 Over Current Protection OCP 1st digit B03 B02 B01 Status of Constant Current CC B00 Status of Constant Voltage CV 81 Status Display 2...

Страница 38: ...STEP 2 SWEEP 118 Sequential Operation Step 2 Control Time Minute 0 9999 minutes 0 minute 119 Sequential Operation Step 2 Control Time 0 1 sec 0 59 9 sec 0 second 120 Sequential Operation Step 3 Pre s...

Страница 39: ...Time 0 1 sec 0 59 9 sec 0 second 145 Sequential Operation Step 8 Pre set CV value 0V Max of each model 0 00V 146 Sequential Operation Step 8 Pre set CC value 0A Max of each model 0 0A 147 Sequential O...

Страница 40: ...played in the bottom Number Display Select Item number 51 with the VOLTAGE dial Set Parameter to 0 1 or 2 with the CURRENT dial Parameter 0 Output is OFF COLD START after power is turned on Pressing t...

Страница 41: ...e complete please follow the procedures below to test verify operation Disconnect the load from the power supply Turn the POWER switch ON with the Output ON OFF Toggle mode FUNC 51 set to 0 Set the Ou...

Страница 42: ...start output When the OVP is triggered the Falling slew rate setting by the slew rate function becomes invalid and the voltage is decreased most rapidly under the condition of that time point MEMO Du...

Страница 43: ...wires that can flow rated current Turn the POWER switch ON with the Output ON OFF Toggle mode FUNC 51 set to 0 Set the Output Current settings lower than OCP level Turn OUTPUT to ON Gradually increas...

Страница 44: ...put When the OCP is triggered the Falling slew rate setting based on the slew rate function is set invalid and the output current is decreased most rapidly under the condition of that time point MEMO...

Страница 45: ...in the bottom Number Display Select Item number 9 with the VOLTAGE dial Set Parameter to 0 1 or 2 with the CURRENT dial Parameter 0 Default value When any alarm occurs switching is stopped forced outp...

Страница 46: ...se check the wiring connection to the input connector Device Detection Error E009 Cannot detect number of parallel devices Restart power supply No of Parallel Connected Devices Over E010 More than 11...

Страница 47: ...ill return to measurement display mode Loading from Memory Single Action Loading Set the parameter for FUNCTION settings item 54 to 0 See page 36 Function Settings on how Press the memory key you wish...

Страница 48: ...n the memory key to be loaded for more than 1 second The light will blink faster until finished Once loading is complete the display will return to measurement display mode Panel Memory Savable Settin...

Страница 49: ...sing as a normal constant voltage power supply for testing equipment and devices 2 Constant Current CC Priority Mode High Medium Low speed Perfect when wishing to control the current of the load such...

Страница 50: ...ending on the number of parallel devices Rated Output Current Io Range Resolution Io 50A 0 01 to Twice the constant output current A s 0 01A 50A Io 500A 0 1 to Twice the constant output current A s 0...

Страница 51: ...alue 5 Falling Current Slew Rate Assign the set value using the CURRENT dial Range Ex 0 1A s to 400 0A s Resolution 0 1A s If using in parallel operation Constant Current CC Slew Rate in page 50 shoul...

Страница 52: ...or multiple HX S G2 Series power supplies simultaneously or using time delays Optional cables T485 M are required for connection Sold separately Sequential ON OFF Connection ON OFF TERMINATION ON ON O...

Страница 53: ...n the Number Display voltage and the parameter will be displayed in the Number Display current Select Item Number 6 with the VOLTAGE dial then set the parameter to 1 with the CURRENT dial Set the Dela...

Страница 54: ...e Master and Slave settings with the CURRENT dial Set the Master to the address 1 Set the Slave to a setting other than the address 1 If there are more than one slaves set the addresses avoiding addre...

Страница 55: ...lected under the FUNCTION Settings Item Number 53 parameters from the following 3 types below Parameter 0 Only the LOCK key can be used Parameter 1 Only the OUTPUT key and LOCK key can be used Paramet...

Страница 56: ...FUNC lamp will light The Setting Item Number will be displayed in the Number Display voltage and the parameter will be displayed in the Number Display current Select Item number 72 with the VOLTAGE d...

Страница 57: ...ximately every 200ms This method is known as the Moving Average Method Setting Procedures Press The Function FUNC key The FUNC lamp will light The Setting Item Number will be displayed in the Number D...

Страница 58: ...ng Item Number will be displayed in the Number Display voltage and the parameter will be displayed in the Number Display current Select Item number 12 with the VOLTAGE dial and Select the operation mo...

Страница 59: ...eter will be displayed in the Number Display current Setting Beep Sound for Pressing Buttons Set the parameter to 90 with the VOLTAGE dial and perform setting with the CURRENT dial 1 With beep sound D...

Страница 60: ...ved by the sequential operation function Control output by setting preset CV CC value control contents STEP or SWEEP and control time 0 1 sec 9999 min 59 9 sec to each steps from step 1 to step 10 ref...

Страница 61: ...s some time to start OUTPUT in actual at OUTPUT ON state due to characteristic of internal circuit Please take note the control time after OUTPUT ON will be not as set Reference time to output the des...

Страница 62: ...ill be the following image when the programing time e g Model 500V type and CV low speed 500ms is longer than control time e g 0 1s Please take note that the waveform dose not rise vertically regardle...

Страница 63: ...1s STEP control Step 2 STEP control Step 3 STEP control Preset CV value 0V Preset CC value 0A Please set the value as shown on the left to set less than 1 sec such as 0V and 0A Voltage Current Elapsed...

Страница 64: ...e power supply for constant voltage CV setting Please refer to page 30 Use as constant current power supply for constant current CC setting Set value for Over Voltage Protection OVP and Over Current P...

Страница 65: ...to the sequential operation for STEP 1 Keep the function key FUNC pressed and select 110 for parameter with VOLTAGE dial and set the desired Preset CV value with CURRENT dial Keep the function key FUN...

Страница 66: ...interval during sequential operation Set Preset CV value Preset CC value Control contents and Control time to the sequential operation after STEP 2 Please refer to page38 FUNCTION setting for sequent...

Страница 67: ...t Measurement Value Voltage Measurement Value Current Measurement Value Repetition Sequential Operation Voltage Measurement Value Current Measurement Value Voltage Measurement Value Current Measuremen...

Страница 68: ...al operation mode 2 Enable Continue 116 Sequential operation No 2 Preset CC value 10 0 A 101 Number of repetition of sequential operation 3 117 Sequential operation No 2 Control contents 2 SWEEP 102 O...

Страница 69: ...Sequential operation No 3 Preset CC value 10 0 A 110 Sequential operation No 1 Preset CV value 5 V 122 Sequential operation No 3 Control contents 2 SWEEP 111 Sequential operation No 1 Preset CC value...

Страница 70: ...HX S G Series Commands External Control Connector SERIAL I F 1 Connector Types RS 232C 3 5 7 9 Pin No 1 TX GND RTS NC Name NC OUT OUT IN OUT 4 6 8 Pin No 2 DTR DSR CTS Name RX OUT IN IN OUT IN Extern...

Страница 71: ...ower supplies on multiple channels via computer When connecting multiple HX S G2 Series power supplies only one communication terminal computer etc can be connected Be sure to set the device address t...

Страница 72: ...cannot be established if settings differ Set the bitrate and parity under FUNCTION Setting Item 61 Bitrate and Item 62 Parity Setting changes will take effect from next startup Command Send Interval W...

Страница 73: ...eived control via communication commands from that point will be released Again when controlling via communication commands command controls will take effect once the device address has been set with...

Страница 74: ...f RS 485 control set to other than 1 PC Set voltage to 5 5V for HX S G2 power supply with device address set to 1 RS 232C RS 485 Connection Configuration Device Address 1 Device Address 2 Note If RS 4...

Страница 75: ...l commands and responses are ASCII character strings One character space is required between command words and parameters Ex ADDRess 1 Within text command word stands for command characters such as AD...

Страница 76: ...l command Inputting SCPI Commands SCPI commands use the following hierarchical structure Ex ALM Root Command CLEar Command CONTain Pass Command CC NRf Command Parameters NRf is a numeric parameter Omi...

Страница 77: ...end of the program message CR LF CR LF CR Carriage Return 0x0d LF Line Feed 0x0A Executing Commands Commands will be executed in the order in which they appear in the program message Invalid commands...

Страница 78: ...T Resets set parameters SET Only IDN Identification Query Function Retrieves device information Name of Manufacturer Name of Model Software Version Format IDN Type QUERY command only Response Name of...

Страница 79: ...tion Assigns the device address for HX S G2 power supplies Format ADDRess NRf Type SET command only Range 0 50 Address 0 is a global address Assign addresses to all multi connected HX S G2 Series DC p...

Страница 80: ...t ALM CLEar Type SET command only No parameters Ex ALM CLE ALM CONTain CC Sets whether to contain CC_STS in LEVEL1_ALM Function Sets whether to contain CC_STS status in LEVEL1_ALM output condition Sam...

Страница 81: ...ame as FUNCTION Settings Item 74 Format ALM CONTain CV NRf Type SET command QUERY command Parameters 0 Does not include in LEVEL1_ALM 1 Includes in LEVEL1_ALM Response 0 1 Restrictions Alarm response...

Страница 82: ...onse Same as parameters Restrictions Alarm response is returned for normal SET commands in the following conditions Cases other than full featured type model name with F While operating as a series op...

Страница 83: ...as a parallel operation slave unit While operating as a series operation slave unit Ex OUTP EXT MODE 1 OUTP EXT MODE 1 OUTPut HOT Sets Output status while POWER is ON Function Sets Output status while...

Страница 84: ...is returned for normal SET commands in the following conditions Cases other than full featured type model name with F While operating as a series operation slave unit While operating as a parallel ope...

Страница 85: ...es QUERY Only POWer DC Retrieves power measurement values QUERY Only MEASure CORRection MODE Sets operation mode for the Linearity Compensation Function Function Sets the operation mode for the Linear...

Страница 86: ...Ex MEAS MVAV 0 MEAS MVAV 0 MEASure SCALar CURRent DC Retrieves Current Measurement Values Function Retrieves current measurement values Format MEASure SCALar CURRent DC Type QUERY command only Respons...

Страница 87: ...ieves electric power measurement values Format MEASure SCALar POWer DC Type QUERY command only Response Returns same resolution data as the power meter Restrictions Alarm response is returned for norm...

Страница 88: ...LEVel Sets OCP Current Both SLEW RISing Sets CC Slew Rate Rising Both FALLing Sets CC Slew Rate Falling Both MEMory RECall Loads from Panel Memory SET Only MODE Sets Loading Order for Panel Memory Bot...

Страница 89: ...6kW 0 to 1260 0 0 to 630 0 0 00 to 75 60 0 00 to 37 80 42kW 0 to 1470 0 0 to 735 0 0 00 to 88 20 0 00 to 44 10 48kW 0 to 1680 0 0 to 840 0 0 0 to 100 8 0 0 to 50 40 54kW 0 to 1890 0 0 to 945 0 0 0 to...

Страница 90: ...0 105 0 48kW 0 0 400 0 0 0 120 0 54kW 0 0 450 0 0 0 135 0 60kW 0 0 500 0 0 0 150 0 66kW 0 0 550 0 0 0 165 0 72kW 0 0 600 0 0 0 180 0 78kW 0 0 650 0 0 0 195 0 84kW 0 0 700 0 0 0 210 0 90kW 0 0 750 0 0...

Страница 91: ...0 42kW 14 0 to 1540 7 0 to 770 0 0 84 to 92 40 0 42 to 46 20 48kW 16 0 to 1760 8 0 to 880 0 1 0 to 105 6 0 48 to 52 80 54kW 18 0 to 1980 9 0 to 990 0 1 1 to 118 8 0 54 to 59 40 60kW 20 0 to 2200 10 0...

Страница 92: ...440 0 12 0 132 0 54kW 45 0 495 0 13 5 148 5 60kW 50 0 550 0 15 0 165 0 66kW 55 0 605 0 16 5 181 5 72kW 60 0 660 0 18 0 198 0 78kW 65 0 715 0 19 5 214 5 84kW 70 0 770 0 21 0 231 0 90kW 75 0 825 0 22 5...

Страница 93: ...42kW 0 to 2800 0 to 1400 0 1 to 168 0 0 42 to 46 20 48kW 0 to 3200 0 to 1600 0 1 to 192 0 0 48 to 52 80 54kW 0 to 3600 0 to 1800 0 1 to 216 0 0 54 to 59 40 60kW 0 to 4000 0 to 2000 0 1 to 240 0 0 60...

Страница 94: ...270 0 60kW 0 1000 0 1 300 0 66kW 0 1100 0 1 330 0 72kW 0 1200 0 1 360 0 78kW 0 1300 0 1 390 0 84kW 0 1400 0 1 420 0 90kW 0 1500 0 1 450 0 96kW 0 1600 0 1 480 0 102kW 0 1700 0 1 510 0 108kW 0 1800 0 1...

Страница 95: ...featured type model name with F While operating as a series operation slave unit While operating as a parallel operation slave unit Ex CURR SLEW FALL 400 0 CURR SLEW FALL 200 0 SOURce MEMory RECall L...

Страница 96: ...conditions While operating as a series operation slave unit While operating as a parallel operation slave unit Ex MEM REC MODE 1 MEM REC MODE 1 SOURce MEMory STORe Saves to Panel Memory Function Saves...

Страница 97: ...0 0 2 0 to 100 1 0 to 6 94 0 05 0 to 27 8 0 2 42kW 0 to 21 4 0 2 0 to 86 1 0 to 5 95 0 05 0 to 23 8 0 2 48kW 0 to 18 8 0 2 0 to 75 0 0 5 0 to 5 21 0 05 0 to 20 8 0 2 54kW 0 to 16 7 0 2 0 to 66 7 0 5...

Страница 98: ...0 3 34 0 02 54kW 0 0 267 0 002 0 2 97 0 02 60kW 0 0 240 0 002 0 2 67 0 02 66kW 0 0 218 0 002 0 2 43 0 02 72kW 0 0 200 0 002 0 2 23 0 02 78kW 0 0 185 0 002 0 2 05 0 02 84kW 0 0 171 0 002 0 1 91 0 02 9...

Страница 99: ...in the following conditions While operating as a series operation slave unit While operating as a parallel operation slave unit Ex VOLT 30 VOLT 30 00 SOURce VOLTage PROTection LEVel Sets OVP voltage...

Страница 100: ...LTage SLEW FALLing Sets CV Slew Rate Falling Function Sets the CV slew rate for falling Same as FUNCTION Settings Item 3 Format SOURce VOLTage SLEW FALLing NRf Type SET command QUERY command Parameter...

Страница 101: ...Status 1 Above OCP level Below OCP level 13 Not Used Always 0 12 EXT_ON Toggling Output ON OFF at External Contacts Input Status ON OFF 11 ALM_BUS_STS SYS_ALM System error Error Normal 10 DD_ON_BUS_S...

Страница 102: ...SET command QUERY command Parameter LEVEL1_ALM OUTPUT ON OFF_STS Response Same as parameters Restrictions Alarm response is normally returned to set command under the following state Alarm is occurrin...

Страница 103: ...analog control signals Both VOLTage MODE Sets mode for Voltage Settings Control Method Both ISOLate Isolated of external analog control signals Both ERRor NEXT Reads Error Message QUERY Only KEYLock...

Страница 104: ...e unit While operating as a parallel operation slave unit Ex SYST COMM SER BAUD 3 SYST COMM SER BAUD 38400 SYSTem COMMunicate SERial RECeive PACE Sets Acknowledge Response Function sets the Acknowledg...

Страница 105: ...its to the Query Response Format SYSTem COMMunicate SERial UNIT NRf Type SET command QUERY command Parameters 0 Do not add units Default Settings 1 Add on units Response Same as parameters Explanation...

Страница 106: ...e operating as a series operation slave unit While operating as a parallel operation slave unit Ex SYST CONT CURR MODE 1 SYST CONT CURR MODE 1 SYSTem CONTrol CURRent ISOLate Sets Isolation for externa...

Страница 107: ...e operating as a series operation slave unit While operating as a parallel operation slave unit Ex SYST CONT VOLT MODE 1 SYST CONT VOLT MODE 1 SYSTem CONTrol VOLTage ISOLate Sets isolation for externa...

Страница 108: ...ror 104 Data type error Data type error Character received instead of numeral in parameter etc 108 Parameter not allowed Too many parameters 109 Missing parameter Too few parameters 120 Numeric data e...

Страница 109: ...owing conditions While operating as a series operation slave unit While operating as a parallel operation slave unit Ex SYST KEYL MODE 1 SYST KEYL MODE 1 SYSTem MONitor MODE Sets Voltmeter Ammeter Dis...

Страница 110: ...al SET commands in the following conditions While operating as a series operation slave unit While operating as a parallel operation slave unit Ex SYST PRES MODE 0 SYST PRES MODE 0 SYSTem SERies Sets...

Страница 111: ...or serious failure or when OVP OCP triggered Restrictions Alarm response is returned for normal SET commands in the following conditions While operating as a parallel operation slave unit Ex SYST TRIP...

Страница 112: ...uery about System Capacity kW Function Retrieves the system capacity kW Format SYSTem POWer Type QUERY command only No parameters Response System capacity kW Restrictions None Ex SYST POW 6 SYSTem STO...

Страница 113: ...for sequential operation Function Set operation mode of DC power supply operation and sequential operation Same as FUNCTION Setting Item 100 Format SEQuence MODE NR1 Type SET command QUERY command Pa...

Страница 114: ...ET command QUERY command Parameter 0 9999 Note 0 Operation will be looped unless any termination request Response Same as parameters Restrictions Alarm response is returned for normal SET commands in...

Страница 115: ...ue note Setting range is depended on the DC power supply Control Time min 0 9999 Control Time sec 0 0 59 9 Control contents 0 OUT OFF 1 STEP 2 SWEEP QUERY command Sequential operation line 1 10 Respon...

Страница 116: ...al operation is in progress Power supply is operating as slave machine in serial operation Power supply is operating as slave machine in parallel operation Ex SEQ STOP 0 SEQ STOP 0 SEQuence STATus Sta...

Страница 117: ...ge A Assigning Device Address Page 119 AR Executes alarm reset Page 119 CL Resets set parameters Page 119 LC Sets OCP current Page 120 LV Sets OVP voltage Page 121 MC Sets Output Current Page 122 MV S...

Страница 118: ...se is received When undefined command is received When command parameters exceed the range When a character or symbol other than numerals 0 9 and decimal point is sent in parameters When sent with a s...

Страница 119: ...ess 1 Bad Example A1 OT1 A2 OT1 Error due to multiple address assignment commands AR Executes Alarm Reset Function Executes alarm reset Cancels generated Over Voltage Over Current alarm Format AR Set...

Страница 120: ...6kW 12 0 to 1320 6 0 to 660 0 0 72 to 79 20 0 36 to 39 60 42kW 14 0 to 1540 7 0 to 770 0 0 84 to 92 40 0 42 to 46 20 48kW 16 0 to 1760 8 0 to 880 0 1 0 to 105 6 0 48 to 52 80 54kW 18 0 to 1980 9 0 to...

Страница 121: ...48 5 60kW 50 0 555 0 15 0 165 0 66kW 55 0 605 0 16 5 181 5 72kW 60 0 660 0 18 0 198 0 78kW 65 0 715 0 19 5 214 5 84kW 70 0 770 0 21 0 231 0 90kW 75 0 825 0 22 5 247 5 96kW 80 0 880 0 24 0 264 0 102kW...

Страница 122: ...0 0 to 525 0 0 00 to 63 00 0 00 to 31 50 36kW 0 to 1260 0 0 to 630 0 0 00 to 75 60 0 00 to 37 80 42kW 0 to 1470 0 0 to 735 0 0 00 to 88 20 0 00 to 44 10 48kW 0 to 1680 0 0 to 840 0 0 0 to 100 8 0 0 t...

Страница 123: ...0 0 735 0 48kW 0 420 0 0 0 840 0 54kW 0 472 5 0 0 945 0 60kW 0 525 0 0 1050 66kW 0 577 5 0 1155 72kW 0 630 0 0 1260 78kW 0 682 0 0 1365 84kW 0 735 0 0 1470 90kW 0 787 5 0 1575 96kW 0 840 0 0 1680 102...

Страница 124: ...te input power relay trip When TRIP is detected or severe breakdown 2 Execute input power relay trip When TRIP is detected severe breakdown OVP OCP triggered Values other than 0 1 or 2 result in param...

Страница 125: ...Value For max no of decimal places refer to Output Current Range in page 122 4 Over Voltage Set Value Max no of decimal places is 1 5 Over Current Set Value For max no of decimal places refer to OCP...

Страница 126: ...pecification isolated OP attached A1 TK2 A1 HX S G2FI MV30 00 MC200 0 LV33 00 LC220 0 TK3 Read Back Status Information Function Retrieves the status information from the HX S G2 power supply with the...

Страница 127: ...S G2 power supply s output voltage measurement value Max no of decimal places is 2 Ex A1 TK4 10 00V TK5 Read Back Measured Current Data Function Retrieves the measured current data from the HX S G2 p...

Страница 128: ...tes Communication control functions using multi connecting cables can be connected with HX S G2 Series and ZX series as well as FK2 series If you want multi connection with other models please contact...

Страница 129: ...M Sold Separately 1 Master 2 Slave n Slave Parallel operation is only possible with the same voltage HX S G2 series models Ex Parallel operation of HX S 030 200G2 and HX S 030 400G2 is possible FUNCT...

Страница 130: ...ating normally will display bars as shown on the right CAUTION Error Codes 1 Error Codes Display List for Master Unit Place Items No Display Voltage No Display Current Content WDT E001 Malfunction of...

Страница 131: ...the same Connecting device models that are different in power capacity will result in breakdown Turn all series connected HX S G2 Series input power POWER switch ON Please calibrate the output voltage...

Страница 132: ...l control connector No 9 terminal Connect wires from the Master s isolated control connector No 16 terminal to the Slave s external control connector No 22 terminal The signal lines of and should be s...

Страница 133: ...current setting value to yA and set the output to ON 30V Type 60V Type 500V Type xV 0 01V 0 01V 0 1V yA 1 0A 1 0A 0 1A 120V Type 400V Type xV 0 1V 0 1V yA 0 1A 0 1A On how to set see Operating as Cons...

Страница 134: ...unit s digital multimeter for output voltage measurement is the same as the display of the Master unit s digital multimeter for output voltage measurement 11 Press the FUNC key of the Slave unit to s...

Страница 135: ...connecting Wire Extract Screwdriver Wire Size 24 16AWG UL Stripped Length 10 0mm 10 0mm 2 5mm 0 4mm How to insert wire into insulation control connector Turn the screw at the upper part of the connec...

Страница 136: ...With Isolation OP 1 Isolation Voltage Monitoring Output No Yes 2 Isolation Common for Voltage Current Monitoring Output No Yes 3 Isolation Current Monitoring Output No Yes 4 Isolation Output Voltage...

Страница 137: ...can be simply removed by pushing down the lock levers on both sides External Control Connector Photocupler or Contact 9 Twisted Pair Wire 22 Open Putput Closed Output Toggling Output ON OFF with Exter...

Страница 138: ...Set this if controlled by the front panel s ON OFF key or by remote control commands Set value 1 Sets Output ON if the external contact is closed and OFF if the external contact is opened Set this if...

Страница 139: ...h with a minimum contact capacity of 5V 2 5mA FUNCTION settings must be changed to Valid for Output ON OFF Control at External Contact Points to be used Factory default settings are set to Invalid Con...

Страница 140: ...Set this if controlled by the front panel s ON OFF key or by remote control command Set value 1 Sets Output ON if the external contact is closed and OFF if the external contact is opened Set this if...

Страница 141: ...ttings are set to Invalid Connecting For the connecting refer to page131 Wire the cables to the isolated control connector accessory terminals No 15 of Slave and the external control connector accesso...

Страница 142: ...Set this if controlled by the front panel s ON OFF key or by remote control command Set value 1 Sets Output ON if the external contact is closed and OFF if the external contact is opened Set this if...

Страница 143: ...es You can choose TRIP operation by short circuit make of contact a and TRIP operation by opening break of contact b MEMO Not suited for power contacts such as main contacts for electromagnetic contac...

Страница 144: ...ontacts 11 24 9 10 a Case of contact a operation selection external control connector No 11 No 24 not connected Closed TRIP b Case of contact a operation selection external control connector No 11 No...

Страница 145: ...age 0 2 of Rated Output Voltage when 10k Connection Connect the resistor between No 7 and 20 of the external control connector accessory Setting Procedures Set the parameter to 2 External Resistance T...

Страница 146: ...d the parameter will be displayed in the Number Display current Select Item number 70 with the VOLTAGE dial Select the parameter with the CURRENT dial 0 Front Panel Default 1 External Voltage 0 to 10V...

Страница 147: ...4 and 17 of the external control connector accessory Setting Procedures Set the parameter to 3 External Resistance Type B according to the procedure on page146 4 17 0 10k Output Voltage Control with E...

Страница 148: ...No 4 and 17 of the external control connector accessory Setting Procedures Set the parameter to 4 External Resistance Type C according to the procedure on page146 4 17 0 10k Output Voltage Control wit...

Страница 149: ...ernal voltage between No 3 and 16 of the external control connector accessory Setting Procedures Set the parameter to 4 External Resistance Type C according to the procedure on page146 External Voltag...

Страница 150: ...la Output Voltage V 10 Resistance External Voltage Output Maximum The output accuracy for the external voltage is the set voltage 0 2 of Rated Output Voltage Connecting Connect the external voltage be...

Страница 151: ...rent 1 of Rated Output Current when 10k Connecting Connect the resistor between No 8 and 20 of the external control connector accessory Setting Procedures Set the parameter to 2 External Resistance Ty...

Страница 152: ...he parameter will be displayed in the Number Display current Select Item number 71 with the VOLTAGE dial Select the parameter with the CURRENT dial 0 Front Panel Default 1 External Voltage 0 10V 2 Ext...

Страница 153: ...eter to 3 External Resistance Type B according to the procedure on page 152 6 19 0 10k External Control Connector Twisted Pair Wire External Resistance Output Current Control with External Resistance...

Страница 154: ...the external control connector accessory Setting Procedures Set the parameter to 4 External Resistance Type C according to the procedure on page152 6 19 0 10k External Control Connector Twisted Pair...

Страница 155: ...he external voltage between No 5 and 18 of the external control connector accessory Setting Procedures Set the parameter to 1 External Voltage according to the procedure on page 152 External Control C...

Страница 156: ...derived from the following formula Output Current A 10 Voltage External Voltage Output Max The output accuracy for the external voltage is the set current 1 0 of Rated Output Current Connecting Conne...

Страница 157: ...the output current monitor is 1 0 10mV Connecting Connect the meter or the recorder between No 2 and 15 of the external control connector accessory External Control Connector 1 Twisted Pair Wire 14 V...

Страница 158: ...put Please use an input impedance of a 10k or more for the external meter Isolated Output Voltage Monitor The accuracy for the output voltage monitor is 0 5 10mV Connecting Connect the meter or the re...

Страница 159: ...UTPUT ON OFF STS OUT PUT ON OFF has occurred 12 LEVEL2_ALM Alarm has occurred Include Several Alarms 13 CV_STS Running in Constant Voltage Mode 14 CC_STS Running in Constant Current Mode 15 P ON M _ST...

Страница 160: ...ess the Function FUNC key The FUNC lamp will light The Setting Item Number will be displayed in the Number Display voltage and the parameter will be displayed in the Number Display current Select the...

Страница 161: ...S Constant Current Operation Setting Procedures Press the Function FUNC key The FUNC lamp will light The Setting Item Number will be displayed in the Number Display voltage and the parameter will be d...

Страница 162: ...Reverse Current IR Power Supply VO Dummy Resistor R Load When This machine does not have functions to stabilize the output voltage against reverse current from loads If the maximum sink current is ex...

Страница 163: ...rent is in a pulsing state This cannot be determined by this device s ammeter alone because it only displays the average output current value If the constant current circuit power limit circuit is tri...

Страница 164: ...m of the parallel connected unit in the case of parallel connection If sensing is done with the secondary battery connected and the reverse current blocking diode equipped a potential difference occur...

Страница 165: ...Special Loads 165 This page is blank...

Страница 166: ...roduct number 12 digit number at the rear panel of product and the firmware version For the firmware version refer to page 34 FUNCTION 0 Daily Maintenance and Inspection Please perform periodic inspec...

Страница 167: ...r Remove the front cover and air filter Please remove the front panel by loosing the screws circled red and pulling the panel by nipping the screws Please remove the air filter from the front cover Th...

Страница 168: ...attach the filter to the back side of the front cover note The picture is HX S 0500 12G4 Insert the positioning parts into the upper hocks on the back side of the front cover Both positioning parts sh...

Страница 169: ...Maintenance 169 This page is blank...

Страница 170: ...advance Power Supply V Digital Multimeter Calibration Circuit 2 Set the constant voltage setting value to xV and the constant current setting value to yA and set the output to ON 30 200 30 400 60 100...

Страница 171: ...ing item number 21 in the Number Display voltage At that time turn off the Number Display current 10 Adjust so that the output voltage becomes xV with the CURRENT dial 30 200 30 400 60 100 60 200 xV 3...

Страница 172: ...V yA 0 10A 0 10A 0 010A 0 01A 120 50 120 100 400 15 400 30 xV 1 0V 1 0V 1 0V 1 0V yA 0 10A 0 1A 0 10A 0 10A On how to set see Operating as Constant Current Power Supply under Basic Operations page30 3...

Страница 173: ...tput current becomes yA with the CURRENT dial 30 200 30 400 60 100 60 200 yA 200 00A 400 00A 100 00A 200 00A DMM display value 50 00mV 40 00mV 25 00mV 50 00mV 500 12 500 24 1000 6 1000 12 yA 12 000A 2...

Страница 174: ...A 1 0A 1 0A 1 0A 1 0A 500 12 500 24 1000 6 1000 12 yA 0 10A 0 10A 0 010A 0 10A 120 50 120 100 400 15 400 30 yA 0 10A 1 0A 0 10A 0 10A On how to set refer to Output Voltage Control with ExternalVoltage...

Страница 175: ...e At that time C or F is displayed in the Number Display current C Coarse adjustment F Fine adjustment 10 Adjust so that the output voltage becomes xV with the CURRENT dial 30 200 30 400 60 100 60 200...

Страница 176: ...to yA and set the output to ON 30 200 30 400 60 100 60 200 yA 1 0A 1 0A 1 0A 1 0A 500 12 500 24 1000 6 1000 12 yA 0 10A 0 10A 0 010A 0 10A 120 50 120 100 400 15 400 30 yA 0 10A 1 0A 0 10A 0 10A On ho...

Страница 177: ...t that time C or F is displayed in the Number Display current C Coarse adjustment F Fine adjustment 10 Adjust so that the output voltage becomes xV with the CURRENT dial 30 200 30 400 60 100 60 200 xV...

Страница 178: ...yA and set the output to ON 30 200 30 400 60 100 60 200 yA 1 0A 1 0A 1 0A 1 0A 500 12 500 24 1000 6 1000 12 yA 0 10A 0 10A 0 010A 0 10A 120 50 120 100 400 15 400 30 yA 0 10A 1 0A 0 10A 0 10A On how to...

Страница 179: ...At that time C or F is displayed in the Number Display current C Coarse adjustment F Fine adjustment 10 Adjust so that the output voltage becomes xV with the CURRENT dial 30 200 30 400 60 100 60 200 x...

Страница 180: ...yA and set the output to ON 30 200 30 400 60 100 60 200 yA 1 0A 1 0A 1 0A 1 0A 500 12 500 24 1000 6 1000 12 yA 0 10A 0 10A 0 010A 0 10A 120 50 120 100 400 15 400 30 yA 0 10A 1 0A 0 10A 0 10A On how t...

Страница 181: ...t that time C or F is displayed in the Number Display current C Coarse adjustment F Fine adjustment 10 Adjust so that the output voltage becomes xV with the CURRENT dial 30 200 30 400 60 100 60 200 xV...

Страница 182: ...1000 6 1000 12 xV 1 0V 1 0V 1V 1V 120 50 120 100 400 15 400 30 xV 1 0V 1 00V 1 0V 1 0V For how to set refer to Output Current Control with External Voltage page155 In the case of isolation refer to Ou...

Страница 183: ...the CURRENT dial 30 200 30 400 60 100 60 200 yA 200 00A 400 00A 100 00A 200 00A DMM display value 50 00mV 40 00mV 25 00mV 50 00mV 500 12 500 24 1000 6 1000 12 yA 12 000A 24 000A 6 000A 12 000A DMM dis...

Страница 184: ...Resistance 0 to 2 Set the constant voltage setting value to xV and the external resistance to infinity open and set the output to ON 30 200 30 400 60 100 60 200 xV 1 00V 1 00V 1 00V 1 00V 500 12 500 2...

Страница 185: ...400 60 100 60 200 yA 200 00A 400 00A 100 00A 200 00A DMM display value 50 00mV 40 00mV 25 00mV 50 00mV 500 12 500 24 1000 6 1000 12 yA 12 000A 24 000A 6 000A 12 000A DMM display value 40 00mV 40 00mV...

Страница 186: ...nal Resistance 0 to 10k 2 Set the constant voltage setting value to xV and the external resistance to 0 and set the output to ON 30 200 30 400 60 100 60 200 xV 1 00V 1 00V 1 00V 1 00V 500 12 500 24 10...

Страница 187: ...0 400 60 100 60 200 yA 200 00A 400 00A 100 00A 200 00A DMM display value 50 00mV 40 00mV 25 00mV 50 00mV 500 12 500 24 1000 6 1000 12 yA 12 000A 24 000A 6 000A 12 000A DMM display value 40 00mV 40 00m...

Страница 188: ...al Resistance 0 to 10k 2 Set the constant voltage setting value to xV and the external resistance to 10k and set the output to ON 30 200 30 400 60 100 60 200 xV 1 00V 1 00V 1 00V 1 00V 500 12 500 24 1...

Страница 189: ...becomes yA with the CURRENT dial 30 200 30 400 60 100 60 200 yA 200 00A 400 00A 100 00A 200 00A DMM display value 50 00mV 40 00mV 25 00mV 50 00mV 500 12 500 24 1000 6 1000 12 yA 12 000A 24 000A 6 000...

Страница 190: ...advance Power Supply V Digital Multimeter Calibration Circuit 2 Set the constant voltage setting value to xV and the constant current setting value to yA and set the output to ON 30 200 30 400 60 100...

Страница 191: ...the FUNC key 9 Turn the VOLTAGE dial to display the setting item number 25 in the Number Display voltage At that time the voltage measured value is displayed in the Number Display current 10 Adjust th...

Страница 192: ...t to ON 30 200 30 400 60 100 60 200 xV 1 00V 1 00V 1 00V 1 00V yA 0 1A 0 1A 0 1A 0 1A 500 12 500 24 1000 6 1000 12 xV 1 0V 1 0V 1V 1V yA 0 10A 0 10A 0 010A 0 01A 120 50 120 100 400 15 400 30 xV 1 0V 1...

Страница 193: ...dial to display the setting item number 27 in the Number Display voltage At that time the current measured value is displayed in the Number Display current The figure above is an example of connectin...

Страница 194: ...constant voltage setting value to xV and the constant current setting value to yA and set the output to ON 30 200 30 400 60 100 60 200 xV 0 00V 0 00V 0 00V 0 00V yA 1 0A 1 0A 1 0A 1 0A 500 12 500 24...

Страница 195: ...mber Display current 11 Adjust the CURRENT dial so that the voltage monitor value is the actual output voltage value digital multimeter measurement a 30 200 30 400 60 100 60 200 a 3 3 6 6 500 12 500 2...

Страница 196: ...ant voltage setting value to xV and the constant current setting value to yA and set the output to ON 30 200 30 400 60 100 60 200 xV 1 00V 1 00V 1 00V 1 00V yA 0 0A 0 0A 0 0A 0 0A 500 12 500 24 1000 6...

Страница 197: ...splay current 11 Adjust the CURRENT dial so that the current monitor value is the actual output current value digital multimeter measurement a 30 200 30 400 60 100 60 200 a 20 40 10 20 500 12 500 24 1...

Страница 198: ...V 60V 60V 120V 120V Rated Output Current 200A 400A 100A 200A 50A 100A Rated Output Power 6000W 12000W 6000W 12000W 6000W 12000W Specification Models 400 15 400 30 500 12 500 24 1000 6 1000 12 Rated Ou...

Страница 199: ...00 24 1000 6 1000 12 Rated power Source AC200V three phase 50 60Hz Rated power 12kVA 23kVA 12kVA 23kVA 12kVA 23kVA Operating power supply AC180V 242V three phase 45Hz 65Hz Input Current 1 32A 64A 32A...

Страница 200: ...s no load Maximum Sink Current 1A 20 2A 20 1A 20 2A 20 500mA 20 1A 20 Residual Voltage when OUTPUT is OFF TYP Below 10mV Specification Models 400 15 400 30 500 12 500 24 1000 6 1000 12 Range 0 0V 420...

Страница 201: ...lue Resolution 10mA 100mA 10mA 1mA 10mA Load Regulation 10 Below 0 05 0 03 of maximum output current Line Regulation 5 Below 0 05 0 005 of maximum output current Ripple Effective Value 6 Below 15mA Be...

Страница 202: ...0 5 2digit 20mA of reading 0 5 4digit 40mA of reading Temperature Coefficient Typical Value 200ppm C Power Meter 4 Digit Digital Meter Maximum Display 14 9 999kW 99 99kW 9 999kW 99 99kW 9 999kW 99 99...

Страница 203: ...ng Temperature Coefficient Typical Value 200ppm C Power Meter 4 Digit Digital Meter Maximum Display 14 9 999kW 99 99kW 9 999kW 99 99kW 9 999kW 99 99kW Accuracy 14 Displays the multiplication value of...

Страница 204: ...12 Over Voltage Protection Circuit OVP Range 4 0 440 0V 5 0V 550 0V 10V 1100V Accuracy 0 2 5digit 0 5V of set value 11 0 2 5digit 5V of set value 11 Operation Can select from operations below Output...

Страница 205: ...100ms CC Priority Low Speed 200ms CV Priority Low Speed 200ms for standard version model name without F Variable Slew Rate Only full featured type model name with F Sets the increasing and falling rat...

Страница 206: ...iority Low Speed 200ms CV Priority Low Speed 500ms for standard version model name without F Variable Slew Rate Only full featured type model name with F Sets the increasing and falling rate for each...

Страница 207: ...on Models 30 200 30 400 60 100 60 200 120 50 120 100 Output Voltage Control External Resistance 0 10k B C Curve 0 A Curve External Voltage 0 10V DC External Voltage Isolated 0 to 10V DC only for isola...

Страница 208: ...at external contact or photocoupler Isolated Usable by external contact or photocoupler only for isolation option featured type model name with I Voltage Monitoring Output Normal For rated output volt...

Страница 209: ...mega ohm tester above 20M Between each input and output input and chassis output and chassis Withstanding Voltage Between input and output 3 0kV AC 1minute Between input and chassis 1 5kV AC 1minute...

Страница 210: ...M12 Bolt Copper Bar M12 Bolt Input Terminal 4P Terminal Board M6 Specification Models 400 15 400 30 500 12 500 24 1000 6 1000 12 External Dimensions mm 15 W 430mm H 129mm D 550mm W 430mm H 221mm D 550...

Страница 211: ...Specifications 211 External Diagrams 1 HX S 030 200G2 F I...

Страница 212: ...Specifications 212 2 HX S 030 400G2 F I...

Страница 213: ...Specifications 213 3 HX S 060 100G2 F I...

Страница 214: ...Specifications 214 4 HX S 060 200G2 F I...

Страница 215: ...Specifications 215 5 HX S 0120 50G2 F I...

Страница 216: ...Specifications 216 6 HX S 0120 100G2 F I...

Страница 217: ...Specifications 217 7 HX S 0400 15G2 F I...

Страница 218: ...Specifications 218 8 HX S 0400 30G2 F I...

Страница 219: ...Specifications 219 9 HX S 0500 12G2 F I...

Страница 220: ...Specifications 220 10 HX S 0500 24G2 F I...

Страница 221: ...Specifications 221 11 HX S 01000 6G2 F I...

Страница 222: ...Specifications 222 12 HX S 01000 12G2 F I...

Страница 223: ...Specifications 223...

Страница 224: ...220 A A 3V 6V 9V 12V 15V 18V 21V 24V 27V 30V 0 10 20 30 40 50 60 0 40 80 120 160 200 240 280 320 360 400 440 A A 3V 6V 9V 12V 15V 18V 21V 24V 27V 30V Output Current vs Input Current Output Current A I...

Страница 225: ...50 60 0 20 40 60 80 100 120 140 160 180 200 220 A A 6V 12V 18V 24V 30V 36V 42V 48V 54V 60V Input Current A Output Current vs Input Current Output Current A Output Output Output Output Output Output Ou...

Страница 226: ...84V 96V 108V 120V 0 10 20 30 40 50 60 0 10 20 30 40 50 60 70 80 90 100 110 Output Current vs Input Current 12V 24V 36V 48V 60V 72V 84V 96V 108V 120V Input Current A Input Current A Output Current A O...

Страница 227: ...240V 280V 320V 360V 400V Output Current A Input Current A 0 10 20 30 40 50 60 0 3 6 9 12 15 18 21 24 27 30 33 Input Current A Output Current A Output Current vs Input Current 4V 40V 80V 120V 160V 200...

Страница 228: ...0 0 2 4 4 8 7 2 9 6 12 0 14 4 16 8 19 2 21 6 24 0 26 4 A A 5V 50V 100V 150V 200V 250V 300V 350V 400V 450V 500V Output Output Output Output Output Output Output Output Output Output Output Output Input...

Страница 229: ...0 0 1 2 2 4 3 6 4 8 6 0 7 2 8 4 9 6 10 8 12 0 13 2 A A 10V 100V 200V 300V 400V 500V 600V 700V 800V 900V 1000V Input Current A Output Current vs Input Current Output Current A Input Current A Output C...

Страница 230: ...21V 24V 27V 30V 0 10 20 30 40 50 60 70 80 90 100 0 40 80 120 160 200 240 280 320 360 400 440 A 3V 6V 9V 12V 15V 18V 21V 24V 27V 30V Output Output Output Output Output Output Output Output Output Outpu...

Страница 231: ...0 30 40 50 60 70 80 90 100 0 20 40 60 80 100 120 140 160 180 200 220 A 6V 12V 18V 24V 30V 36V 42V 48V 54V 60V Output Efficiency Output Current vs Efficiency Output Current A Efficiency Output Current...

Страница 232: ...6V 108V 120V Output Output Output Output Output Output Output Output Output 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 110 Output Current A Output Current vs Efficiency 12V 24V...

Страница 233: ...nc 4V 40V 80V 120V 160V 200V 240V 280V 320V 360V 400V 0 10 20 30 40 50 60 70 80 90 100 0 3 6 9 12 15 18 21 24 27 30 33 Output Current A Output Current A Output Current vs Efficienc 4V 40V 80V 120V 160...

Страница 234: ...0 60 70 80 90 100 0 0 2 4 4 8 7 2 9 6 12 0 14 4 16 8 19 2 21 6 24 0 26 4 A 5V 50V 100V 150V 200V 250V 300V 350V 400V 450V 500V Output Output Output Output Output Output Output Output Output Output Out...

Страница 235: ...40 50 60 70 80 90 100 0 0 1 2 2 4 3 6 4 8 6 0 7 2 8 4 9 6 10 8 12 0 13 2 A 10V 100V 200V 300V 400V 500V 600V 700V 800V 900V 1000V Efficiency Output Current vs Efficiency Output Current A Efficiency O...

Страница 236: ...nt Wave Form The entire waveform when you enter the AC242V The expansion waveform when you enter the AC242V Output timing for the HOTSTART setting Input Voltage 1 V div Input Current 50A div Input Cur...

Страница 237: ...Appendix 237 Appendix 4 Loaded Current vs Recommended Conductor Area Recommended Sectional Conductor Area mm2 Load Current...

Страница 238: ...OFF Rectifier Circuit To each part Insulation Inverter Converter POWER BLOCK P ON GOOD Deteciton Circuit OUT ON Signal TRIP Signal DC OUTPUT S S Current Detection Resistance Constant Current Error Amp...

Страница 239: ......

Страница 240: ...Appendix 240 Postal code 213 8558 24 16 Mizonokuchi 1 chome Takatsu ku Kawasaki shi Kanagawa 213 8558 Japan HX S G2 Series Instruction Manual July 2021 Ver2 0 DOC 2006 02...

Отзывы: