WARNING FOR INSTALLATIONS
FOR YOUR SAFETY, READ BEFORE INSTALLATION:
Do not install the heater where water, debris or
flammable vapors may get into the flue terminal.
This may cause damage to the heater and void the
warranty.
Do not have the vent terminal pointing toward
any opening into a building. Do not locate your
water heater in a pit or location where gas and
water can accumulate.
Do not install this water heater under an
overhang less than 3 ft. (914 mm) from its top
or eaves. The area under an overhang must be
open to three sides (Outdoor models only).
Do not install the water heater direct vent ter-
minator within 1 ft. (30 cm) in the USA of any air
intake or building opening, and within 3 ft. (91
cm) in Canada of any air intake or building open-
ing ( Refer to pp. 24 and 25.).
Do not install next to a dryer or any source
of airborne debris that can be trapped inside
the combustion chamber, unless the system
is direct-vented. The air intake must maintain
a safe distance from the dryer's exhaust vent.
This will help to prevent lint from being drawn
into the water heater's air intake.
Prohibited
Prohibited
1 ft. (30 cm) min. USA
3 ft. (91 cm) min. Canada
1 ft. (30 cm) min. USA
3 ft. (91 cm) min. Canada
1 ft. (30 cm) min. USA
3 ft. (91 cm) min. Canada
12-inches (30.48 cm) above grade
or anticipated snow level
Anticipated snow level
3 ft.
(914 mm)
Installation
Installation Manual
Water heater vent terminator must be at least 2
ft. (610 mm) away from an inside corner for both
outdoor installation, indoor single vent, or direct-
vent installation.
Inside
Corner
2 ft.
(610 mm)