- 31 -
Receiver
Þ
Press
Frequency
key to set
38kHz or 512Hz
.
Set the detection mode to Probe mode.
Depth measurement
Þ
Press
DEPTH
key
* For the Sewer probe :
OVER
Þ
Change the output to OUTPUT LOW.
LOW
Þ
Change the output to OUTPUT HIGH.
* If tracking a boring tool, Probe should be housed in a metal housing with slots milled in housing to
allow signal to escape. Location is done as above.
Depth
Current index is not displayed.
Tracing a non-metallic drain or plastic pipe with the Probe.
Ex. Feed the Probe into the PVC pipe and locate
the blockage or collapse
Press Mode
key three times
PROB OFF
Pipe & Cable mode
PROB ON
Probe mode
Press Frequency key
Apply
Peak mode
. Horizontal direction
can not be detected with Null mode.
Use the Receiver right angle to the object
line like the drawing
Location measurement
( horizontal direction of the line)
Peak mode.
Three sensitivity peaks appears.
The biggest peak is the point direct
above the Probe.
Location measurement (Same direction in the line)
Null mode
Near the direct above the Probe, arrow
indicates the direct above the Probe.
Away from the direct above the Probe,
the receiving level flashes and the
arrow indicates opposite direction.