- 17 -
7-2. External coil mode
Use 9.5 kHz, 38 kHz or 80kHz External coil supplied as an option. Use this mode if object is accessible.
An induced current, generated by the coil in the External Coil attachment, is applied directly to the exposed
part of the cable / pipe to be located.
Applicable to : Live Telecom cable or Live Power cable. Fiber optic cable having an aluminum-sheath.
When the External coil is connected to the transmitter, External coil mode is automatically selected.
Frequency setting
Adjust output power
Connect the External coil to the target line.
Note :Make sure it is attached parallel and in line with the cable as illustrated.
This Groove is up
External Coil mode indication
When 38kHz coil is
connected
Transmitting coil
*The jaws do not have to be closed around the cable.
(This coil method is different from the conventional clamp
that must have jaws perfectly closed. Different size clamps
are not needed. The Verifier coil method uses the indirect /
Inductive principle.)
Indicate output power with the bar
graph and the numerical value when
pressing / key.
Reduce output
power
increase output
power
Electromagnetic field
Telecom / Power cable
(Diameter up to 10cm / 4”)
Frequency is selected based on coil used
with the External coil automatically.
External coil
*Set a receiving frequency on the Receiver the same
as the transmitter.
Press
Frequency
key