- 13 -
Mode of Detection
Purpose of usage
This is the best way to inject AC current direct to the target line.
Signal (AC current) will return to the Transmitter through the
ground.
Effective for detecting the target line in congested areas.
Advantage for live power or cable, that is not accessible for
Direct connection.
The clamp is waterproof and will attach on any size cable.
No need for a ground stake.
Effective for detecting the target line in congested area.
The target line must be grounded.
If there is no direct access to the target line, use this method.
The Transmitter can induce its signal to the buried line.
Place the Transmitter in an upright position and at right angle to
the buried line.
Minimum TX to RX distance
Þ
30 ft / 10 m
Note: When using the indirect mode, set the depth mode of the receiver
to 0-5m (0-16ft.) .Depth measurement error gets bigger at near the
Transmitter when 0-10m (30ft) is applied.
Used with External Coil to find wiring systems in the building.
TX's circuit is protected* up to 250V at 50 / 60 Hz.
*512Hz output is cut off automatically.
Used for tracing small diameter drains or plastic pipes.
Also, pinpoint a drain blockage or collapse. Can trace non-
directional boring tools.
The Probe is available in two sizes,
20mm/ 0.79" and 50mm / 2" diameter.
External Coil Mode
Direct Connection Mode
Building Wiring
Probe Mode
Indirect (Inductive) Mode
7. Operation of Transmitter (TX)
Signal
Black clip
Transmitter
Red clip
Target line
Ground stake
Ground
Signal
Signal
Содержание VerifierG2 MPL-H10S
Страница 1: ......