217
Countermeasure when the machine stopped
Chapter 9
1
2
3
4
5
6
7
8
9
10
11
1-3.
Stop due to malfunction
It is displayed in red on the screen. It is caused by card, harness or communication error. If the below
code No. is displayed, consult the distributor.
BF1
At network connection to host PC, IP address was
not obtainable from DNS server.
Check IP address of DNS server. Correct “IP
Setting.ini” file. Check operating condition of
DNS server.
BF2
The contents of “IP Setting.ini” file for network set-
ting was incorrect
Correct the contents of “IP Setting.ini” file.
5B1
It is not possible to input data due to abnormal
contents of configuration in TCF design.
Check the design.
5C1
Data set was performed without frame origin
memory after installation of software.
The machine was stopped during operation of frame
origin memory.
Perform frame origin memory.
5C2
Machine was started during moving up/down of
sequin device.
Start the device after completion of up/down.
5C3 Setting error of sequin device III
Check the setting of panel.
5C6 General external device is operating.
Operate the machine after general external
device is stopped.
No.
Stop Factor
How to restore
311
Encoder A signal does not change for 5 seconds.
Abnormality of motor, motor belt (It is not dis-
played for the single-head machine.)
Check connection of the encoder signal lines.
Check excitation of the main shaft driver.
Check the motor or motor belt.
312
Fixed position signal (Main shaft Z signal) does
not change during operation.
Press the E key. Check the main shaft motor or
the photo-interrupter card.When recovery is
impossible, replace the main shaft motor or the
photo-interrupter card.
316 Main shaft motor error or main shaft driver error
Turn "OFF/ON" the power. Or switch from
sleep mode to normal mode. (Each driver
setting will be reset.) When it is not possible to
recover from the trouble, replace the card.
322-
Abnormality of X-axis driver
Description of mark differs depending on factor.
The same is applied to No.323.
323- Abnormality of Y-axis driver
No.
Stop Factor
How to restore
Information error of head number
The setting conflicts with the actual
[3C3]
"Reset" >>E
Code No.
Stop Factor
* *
*
Содержание TFMX-IIC
Страница 2: ...TISM...
Страница 14: ...To search from the menu key...
Страница 39: ...25 1 2 3 4 5 6 7 8 9 10 11 Chapter 3 Screen 1 Screen display 26 2 Message display 31...
Страница 90: ...Embroidery starts 76 Chapter 4...
Страница 158: ...Functions that must be remembered 144 Chapter 5...
Страница 202: ...Design saved in USB memory 188 Chapter 7...
Страница 213: ...To make optional device available for use 199 Chapter 8 1 2 3 4 5 6 7 8 9 10 11 2 To use Bobbin changer YES 6 7 6 7...
Страница 226: ...Functions concerning optional device 212 Chapter 8...
Страница 250: ...236 Inspection Repair Chapter 10...
Страница 266: ...Index...
Страница 267: ...1st Edition June 2004 47th Edition April 2020...
Страница 268: ......