42
Module Specifications
TB9400 Specifications Manual
© Tait Limited July 2017
2.3
PMU
2.3.1
Identifying the PMU
You can identify the model and hardware configuration of a PMU by
referring to the product code printed on labels on the front and rear panels.
The meaning of each character in the product code is explained in the table
below.
Notice
This explanation of PMU product codes is not intended to
suggest that any combination of features is necessarily available in any
one PMU. Consult your regional Tait office for more information
regarding the availability of specific models and options.
Product Code
Description
TBA
X
XXX-XXXX
3 = PMU
TBA3
X
XX-XXXX
0 = default
TBA3X
X
X-XXXX
0 = AC module not fitted
A = AC module fitted
TBA3XX
X
-XXXX
0 = DC module not fitted
1 = 12V DC module fitted
2 = 24V DC module fitted
4 = 48V DC module fitted
TBA3XXX-
X
XXX
0 = standby power supply card not fitted
1 = 12VDC standby power supply card fitted
2 = 24VDC standby power supply card fitted
4 = 48VDC standby power supply card fitted
TBA3XXX-X
X
XX
0 = auxiliary power supply board not fitted
1 = 12VDC auxiliary power supply board fitted
2 = 24VDC auxiliary power supply board fitted
4 = 48VDC auxiliary power supply board fitted
TBA3XXX-XX
X
X
0 = default
TBA3XXX-XXX
X
0 = default