54
Installation
TB9100 Installation and Operation Manual
© Tait Electronics Limited May 2006
Control Panel Connections
Power Supply Connections
AC Power
The TB9100 PMU is designed to accept a mains input of 88 to 264VAC at
45 to 65 Hz. We recommend that a 3-wire grounded outlet be used to
supply the AC power. The socket-outlet must be installed near the
equipment and must be easily accessible. This outlet should be connected to
an AC power supply capable of providing at least 600 W. The requirements
of two typical AC supplies are given in the following table.
Your TB9100 base station should come
supplied with a power supply cord to
connect the male IEC connector on the
PMU to the local AC supply. The pins of
the IEC connector on the PMU are
identified at right.
DC Power with PMU
The TB9100 PMU is designed to accept a nominal 12 VDC, 24 VDC or
48VDC input (depending on the model) with negative or positive ground.
There is a minimum DC startup threshold to prevent damaging a battery
which has little capacity left.
Figure 4.10
Control panel inputs and outputs
b
DC outputs for fans mounted on front panel;
also used for fan rotation detectors (if fitted)
c
microphone connector
b
c
Nominal Supply
Current Requirement
Circuit Breaker/Fuse
Rating
115VAC
8A
10A
230VAC
4A
6A
ground
rear view
neutral
phase
Содержание TB9100
Страница 1: ...MBA 00002 05 Issue 5 May 2006 TB9100 base station Installation and Operation Manual...
Страница 6: ...6 TB9100 Installation and Operation Manual Tait Electronics Limited May 2006 Glossary 131...
Страница 26: ...26 Description TB9100 Installation and Operation Manual Tait Electronics Limited May 2006...
Страница 34: ...34 Maintenance TB9100 Installation and Operation Manual Tait Electronics Limited May 2006...
Страница 60: ...60 Installation TB9100 Installation and Operation Manual Tait Electronics Limited May 2006...
Страница 70: ...70 Base Station Operation TB9100 Installation and Operation Manual Tait Electronics Limited May 2006...
Страница 74: ...74 TB9100 Installation and Operation Manual Tait Electronics Limited May 2006...
Страница 122: ...122 Technical Description TB9100 Installation and Operation Manual Tait Electronics Limited May 2006...
Страница 126: ...126 Appendix A Interface Pin Assignments TB9100 Installation and Operation Manual Tait Electronics Limited May 2006...
Страница 130: ...130 Appendix B Inter Module Connections TB9100 Installation and Operation Manual Tait Electronics Limited May 2006...