184
Frequency Synthesizer Fault Finding
TB7100 Service Manual
© Tait Electronics Limited
October 2005
Task 29 —
Repair PLL feedback
If both the maximum and minimum VCO frequencies are correct, then the
PLL feedback is suspect.
1.
Resolder R542 in position (see
).
2.
Remove the
VCO
BOT
can.
3.
Replace the components L510 (see
) and IC503
(see
).
4.
Confirm that the fault in the radio has been removed. If it has, go to
. If it has not, replace the main-board
assembly and go to
Figure 11.13 Synthesizer circuitry under the
VCO
BOT
can (VHF radio, bottom side)
VCO BOT
1
2
3