![Taiden hcs-8300 Скачать руководство пользователя страница 80](http://html1.mh-extra.com/html/taiden/hcs-8300/hcs-8300_installation-and-operation-manual_813761080.webp)
67
3.3.3 Connection
3.3.3.1 Connecting to the CMU or the EMU
The HCS-8335 series economical multimedia terminal
is equipped with a 1.5-meter 6P-DIN cable with a
standard male connector. To connect to the HCS-8300
CMU or the HCS-8300 EMU, just connect the male
connector of the first terminal to the output of the main
unit.
If there is a long distance between the multimedia
terminal and the CMU (EMU), CBL6PS extension cable
can be used. One end is equipped with a 6P-DIN male
connector and the opposite end with a female
connector. Just connect the female connector of the
cable to the next multimedia terminal, and connect the
male connector to the output of the main unit.
Figure 3.3.3 HCS-8335 series economical multimedia
terminal connected to the CMU/EMU
Neither the replacement of multimedia terminals nor
cable faults between multimedia terminals will affect
the other terminals if “Closed Loop - Daisy Chain”
connection topology is selected. “Closed Loop - Daisy
Chain” connection, achieved by closing the loop of the
daisy-chained units, increases system reliability. To
obtain “Closed Loop - Daisy Chain” connection, just
connect the last multimedia terminal back to the CMU
or the EMU with a CBL6PP extension cable (the cable
features a 6P-DIN male connector at each end). In
HCS-8300 series system, the congress main unit can
realize a “Closed Loop - Daisy Chain” connection, but
only one – extension units do not offer this feature.
Figure 3.3.4 “Closed Loop - Daisy Chain” connection
between the CMU and HCS-8335 series economical
multimedia terminals
3.3.3.2 Connection between congress units
The HCS-8335 series economical multimedia terminals
are daisy-chained easily and conveniently by dedicated
6P-DIN cables.
When connecting to another multimedia terminal, just
connect the 6P-DIN standard female connector on the
0.6-meter cable of the unit to the 6P-DIN standard male
connector on the1.5-meter cable of the next unit.
Figure 3.3.5 “Daisy-chain” connection between
HCS-8335 series economical multimedia terminals
Содержание hcs-8300
Страница 22: ...9 Figure 1 1 6 CongressMatrix TM Software Interface ...
Страница 25: ...12 Figure 1 1 10 By using microphone array terminals the conference room looks tidy ...
Страница 89: ...76 3 4 2 Installation Figure 3 4 2 Fixing of HCS 8336 SDI monitor ...
Страница 93: ...80 B About Display the product information including unit ID serial and version ...
Страница 121: ...108 4 1 HCS 4385U 50 4 1 1 Functions and indications Front Side Bottom Figure 4 1 1 HCS 4385U 50 Interpreter unit ...
Страница 134: ...121 4 2 HCS 8385 4 2 1 Functions and indications Front Side Bottom Figure 4 2 1 HCS 8385 Interpreter unit ...
Страница 168: ...155 Figure 6 1 3 CMU connecting to infrared language distribution system via HCS 8300MO ...
Страница 210: ...197 6 9 2 Connection Figure 6 9 4 Connection between the HCS 8301M and the HCS 8300MAU FS ...
Страница 249: ...236 Appendices Custom made cables AppendixⅠ Dedicated 6 PIN Extension Cable ...
Страница 250: ...237 Appendix Ⅱ CBL2SS 01 Professional 2 pin Cable for Conference System ...
Страница 251: ...238 Appendix Ⅲ CBL4PK 01 Power Adapter Cable ...
Страница 252: ...239 Appendix Ⅳ CBL4PT 02 Power Branch Cable ...
Страница 253: ...240 Appendix Ⅴ CBL4PS 4 pin Extension Cable ...
Страница 254: ...241 Appendix Ⅵ Cat 6 Gigabit Ethernet Cable ...