background image

__________________________________________________________________________________________________________________ 
 
TAGLab  

                                                                                                                                                                                   Battery Charger | 

C4

 

No. 

Functions 

MODE

 button for selecting the voltage - 6V or 12V  

The Red LED will light up next to 6V or 12V as per the selection. 

C4 Charger 

Quick connection plug 

Terminal connection cable 

(+)

 with clamp (red) 

Terminal connection cable 

(-)

 with clamp (black) 

Terminal connection cable 

(-)

 with ring lug (black) 

Terminal connection cable 

(+)

 with ring lug (red) 

Mains cable 

Error

 – Red LED - see “Troubleshooting”. 

10 

Full

 – Green LED - Lights up once the connected battery is fully charged. 

11 

Charge

 – Orange LED - Lights up during the charging process. 

12 

Power

 – Green LED - Lights up whilst the charger is connected to the 230V / 50Hz mains 

socket. 

13 

Mounting hook 

 

 

 

 

 

 

 

 

 

 

 

Содержание C4

Страница 1: ..._______________________________________________________________________________________________________________ TAGLab Battery Charger C4 C4 Battery Charger User Manual Battery Charger User Manual EN 1 16 ...

Страница 2: ...__________________________________________________________________________________________________________________ TAGLab Battery Charger C4 Battery Charger User Manual ...

Страница 3: ...ck connection plug 4 Terminal connection cable with clamp red 5 Terminal connection cable with clamp black 6 Terminal connection cable with ring lug black 7 Terminal connection cable with ring lug red 8 Mains cable 9 Error Red LED see Troubleshooting 10 Full Green LED Lights up once the connected battery is fully charged 11 Charge Orange LED Lights up during the charging process 12 Power Green LED...

Страница 4: ...f delivery 6 Technical data 6 Safety 7 Product Description 9 Operation Output Voltage 9 Before Use 9 Connecting the Charger 10 Operating the Charger 11 Charging Time 11 Disconnecting the Charger 11 Back up Power Supply 11 Alternator Testing 11 Maintenance Diagnostic 12 Charging Phases 12 Safety Functions 14 Troubleshooting 14 Information Care 16 Disposal 16 Warranty 16 ...

Страница 5: ...et first Class II appliance No earth connection is required Double insulated casing Dust and water resistant Never dispose the electrical equipment with daily waste Attention On certain vehicles disconnection of the battery may lead to a loss of information and not being able to restart Refer to the vehicle manufacturer s instruction manual Carefully study the user manual The user manual should be...

Страница 6: ...involves significant risks The manufacturer assumes no liability for damages due to improper use A sealed battery will not have removable caps and requires no maintenance It is important that the charging voltage does not exceed the gas release threshold This charger is particularly suited to these batteries Scope of Delivery Charger Mains cable Quick connection plug Clamp terminal connection cabl...

Страница 7: ...osive mixture of hydrogen gas and oxygen Contact with naked flames hot surfaces or sparks will cause an electrolytic gas reaction Avoid flames and sparks Never connect the charger if you notice a smell of gas or fuel Always perform charging in a well ventilated area The charger must be connected to an easily accessible 230V 50Hz mains socket Never operate the device if the power supply cable is da...

Страница 8: ...rging cable to prevent damaging the charger The charging cable must never make contact with any fuel pipes e g gasoline pipes Do not pour liquid on the charger as there is a risk of electrocution Never cover the charger when the device is in operation Make sure there is no risk of explosive or flammable substances e g gasoline or solvent being ignited whilst using the charger Do not expose to heat...

Страница 9: ...V or 12V the battery charger will recognise the battery capacity and the battery condition and calculate the required charging parameters charging voltage charging current This allows for efficient and safe charging If the wrong battery voltage is set or the battery is defective it will not charge and the Error LED will light up also see Troubleshooting The trickle charge function allows the charg...

Страница 10: ...e required terminal connection cable with rings or clamps to the quick plug connection 3 Connect the red terminal connector cable to the positive terminal of the battery Connect the black terminal connector cable to the negative terminal of the battery The black clamp can also be connected to the vehicle body however away from the fuel pipes Please refer to the vehicle manufacturer s instructions ...

Страница 11: ...recharged correctly The charger may indicate such battery as charged In this case the battery may no longer be used and must be changed Battery requires regular maintenance and does not have an unlimited service life over time This is why the battery must be maintained by way of monthly recharges in the event of not being used for prolonged periods Disconnecting the Charger Completing charging and...

Страница 12: ...the battery during the charge holding the charging current increases accordingly The charger can remain connected to a battery without any harmful overcharge Incorrect Polarity Disconnect the charger from the mains and correct the connection to the battery Diagnostic The diagnostic function is provided to automatically check the status of the battery and recognize the voltage Charging Phases The c...

Страница 13: ...harging current to return the battery to a chargeable state Stage 4 Soft start The battery is gently charged with a low charging current Stage 5 Primary charging CC1 CC2 CC3 Constant Current The battery is quickly and safely charged at the maximum charging current Stage 6 Absorption CV Constant Voltage The battery is charged at a current end of charge voltage until charging current no longer flows...

Страница 14: ...V is required to start a charge Separate the charger from the mains and check the connection Error Possible Cause Solution The Error LED indicator lamp 9 goes on Battery defective The battery voltage is less than 1 5V and greater than 0 5V The battery voltage is less than 5V for a 6V battery or less than 11V for a 12V battery after charging the battery for 4 minutes Battery voltage is under 6V or ...

Страница 15: ...heck the battery connection ensure that there is a good connection at the battery terminal post and or vehicle chassis High charging time In the event of low temperatures under 0 C the charge is only performed with a very low current This will extend the charging time As the battery warms up the charging current is adjusted accordingly Charge the battery in normal conditions Risk of explosion Neve...

Страница 16: ...ly to be repaired by qualified technician using genuine spare parts so as to maintain operating reliability Disposal The product must not be disposed of in the household waste but suitably recycled Do not throw electrical appliances in with domestic waste Illustrations may vary slightly from the product itself We reserve the right to modify the product in accordance with technical advances Additio...