background image

24

• 

Store and use the product in a dry, clean and ventilated room.

• 

Do not place the product in direct sunlight, next to a radiator/heater or some place where the system may be 
subjected to liquids.

• 

All plugs are designed to be used in one way only. Therefore, you should never use force when you connect the system.

• 

Remember to disconnect all elements if you intend to move the product.

• 

If you move the product from a cold to a hot room, you must wait at least an hour before you turn it on to avoid short 
circuits due to condensation.

• 

Remove the cables by pulling the plug itself - never by pulling the cable.

• 

If the product needs repairing, never do it yourself, contact your distributor.

• 

When cleaning the product, please turn off the system and wait untill the system has cooled off.

• 

Clean the product with a damp cloth. Never use strong cleaning agents or chemicals  
- these may damage the microscope.

• 

Clean the lens regularly with isopropyl alcohol and a microfiber cloth or with the TAGARNO cleaning kit.

MAINTENANCE

WARRANTY

Warranty terms for the product shall be as follows:

TAGARNO warrants that the product will correspond with the specification at the time of delivery and will be free from 
defects in material and workmanship for a period of 24 months 

 

(2 years) from date of invoice from Supplier.

This warranty covers:

         a.              The replacement of defective parts.
         b.              All labour costs to exchange defective parts in product.
         c.              Complete functions test of product before return to end user’s site.

         d.              Return transport costs of product from TAGARNO to end user’s site.

The warranty only applies if the product is packed, shipped, stored, handled and maintained correctly.

      

Failures due to improper packing and transport are not covered.

Failures due to drops and sudden blows are not covered.
Failures due to storage and handling in extreme high or low temperatures are not covered.
Failures due to storage or handling in extreme high humidity are not covered.

ERGONOMIC RECOMMENDATIONS

Please be careful when carrying the product from one place to another.

Values marked with X varies from product to product and are replaced by specific numbers and letters. 

All TAGARNO products are marked with a product label:

Always lift the microscope with one hand around the rod and the other hand beneath the base.
Please do not lift the microscope by grabbing the camera arm. 

This TAGARNO product contains open source and third-party components. 

www.tagarno.com/license-agreement

LICENSE AGREEMENT

15. MAINTENANCE

16. WARRANTY

17. LICENSE AGREEMENT

18. ERGONOMIC RECOMMENDATIONS

Содержание FHD PRESTIGE

Страница 1: ...SETUP MENU 10 9 STANDARD APPS 15 11 SYSTEM UPDATE 18 12 LICENSE ACTIVATION 20 13 TECHNICAL SPECIFICATIONS 21 14 PC REQUIREMENTS 23 15 MAINTENANCE 24 16 WARRANTY 24 18 ERGONOMIC RECOMMENDATIONS 24 19...

Страница 2: ...ways turn off the system before unplugging when possible WARNINGS The product is a digital magnifying system consisting of a camera unit PCBs mechanical parts and a power supply The product is intende...

Страница 3: ...ffusor lens kit Fresnel lens kit 100 mm for Lens 1x Plan 4 YOU HAVE RECEIVED Smart guide Camera arm with lens Base Rod washers screw OPTIONS XPLUS FHD control box Power supply USB A B 3 0 cable Hex ke...

Страница 4: ...lly and horizontally on top of the base Fasten the two washers with the screw on top of the rod Pull the release button and place the camera arm on the rod The complete microscope with base 5 ASSEMBLI...

Страница 5: ...trol box Output 3 3V 6A Max Use only control boxes supplied by TAGARNO 4 Output HDMI Standard Type A Monitor HDMI Out 1080p60 5 Ethernet RJ 45 Ethernet wall socket Ethernet LAN 100BASE TX 1000BASE T 6...

Страница 6: ...Power on off Place the camera arm in the appropriate height according to the lens you are using Adjust the friction according to your personal preference 7 OPERATION TIP Find the How to Use tutorial v...

Страница 7: ...ou wish to focus on something very close Push this button on the control box to adjust focus if you wish to focus on something that is farther away To turn the autofocus on again simply push both zoom...

Страница 8: ...to USB or your microscope internal storage press the image capture button until you hear a beep Long press on the same button will save an image with graphics causing the live image to freeze for a fe...

Страница 9: ...e right and left arrows to choose between the different settings in the microscope menu Activate an application or submenu by pressing Enter If you have selected Exit pressing Enter will close down th...

Страница 10: ...lat surface Follow the on screen directions to find the optimal working distance The magnification settings prior to performance will be restored 3 Close up Lens Indicate which lens is mounted on your...

Страница 11: ...haracters missing in the scanned image name 16 Image preview This feature allows users to quickly inspect and capture images of new samples When an image is captured the default behavior is to preview...

Страница 12: ...Japanese Korean Polish Romanian Russian and Spanish 11 Keyboard layout Select your horizontally language by pressing buttons left or right on the XPLUS control box The available languages are listed a...

Страница 13: ...top of your live image on screen For more info see manual section STANDARD APPS 4 Watermark Create an info field on captured images with an image prefix time stamp horizontal field of view microscope...

Страница 14: ...torage does not currently have this file system use this function to format the USB storage A second pop up will ask you to confirm your selection Please notice that all files on the USB memory stick...

Страница 15: ...or cancel an ongoing focus stacking All current settings used during Focus stacking except zoom level are persisted during power down 2 RULER With Ruler you can add vertical and or horizontal rulers i...

Страница 16: ...ings at the same time 2 Enable or disable info field Enable or disable an info field automatically stating an image prefix default or as stated under Camera settings time stamp horizontal field of vie...

Страница 17: ...ss of method verify that an IP address of the microscope is displayed in the microscope System information If no IP address is stated check that all cables are connected correctly or consult a network...

Страница 18: ...k www tagarno com firmware download 2 Download the installation file s to a USB memory stick FAT32 formatted 3 If the file s is in a ZIP folder unzip the files and make sure that only the correct inst...

Страница 19: ...m update STEP 5 VERIFY INSTALLATION 1 Verify the system update by checking that the Application version displayed in the Setup menu Info System information matches the version of the system update fil...

Страница 20: ...it with a unique license key file To activate a license key on your TAGARNO microscope follow the steps below Note The license can only be paired with the microscope which has the serial number state...

Страница 21: ...Monitor Detect Yes Plug connection 2 x USB 2 0 Type A Socket USB 3 0 output Type B Socket Control box D SUB 9 Pin Female ESD Snap Socket 10mm Monitor output HDMI Standard Type A Power supply DC Jack E...

Страница 22: ...tor arm Flexarm XPLUS FHD Control box Table mount monitor arm Cleaning kit Foot switch Wall mount monitor arm Dust cover TAGARNO Ring light White Circular tilting table Coaxial light TAGARNO Ring ligh...

Страница 23: ...Vidia GeForce GT 740M with 2GB RAM Monitor resolution 1920x1080 FULL HD 1080P 25 30HZ OS Desktop Laptop Windows 7 8 or 10 with DirectX 11 Memory 4GB CPU Intel Core Dual 3 0GHz or i3 2 4GHz 4th generat...

Страница 24: ...will be free from defects in material and workmanship for a period of 24 months 2 years from date of invoice from Supplier This warranty covers a The replacement of defective parts b All labour costs...

Страница 25: ...PTION TAGARNO A S hereby declares that the product listed above consisting of a camera unit and a 12V power supply is in compliance with the following European directives 2006 25 EU 2014 30 EU 2014 35...

Страница 26: ...ncy energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to...

Отзывы: