Coral IPx Office Installation Manual
Initial Power-up Tests
3-5
Co
mm
on
C
ont
ro
l T
est
3
3.2
Common Control Test
This section deals with the Common Control Test. This test checks that the system has
initialized properly and that the memory lithium battery is functional.
0
Control card initialization includes two stages:
Activating the power supply card and checking the LED indicators for
functionality
Checking the PI device for successful initialization.
The MCB Office control card layout is shown in
.
Activating the Control Card
1.
In the main cage and in the expansion cages, verify that the PS Office power
switch is in the OFF position (turned downwards).
2.
Verify that all peripheral cards in the IPx Office unit are completely installed.
3.
Verify that all peripheral cards in the expansion cages protrude from the cage
by approximately 1 inch (2.5 cm).
4.
Verify that the SAU is attached to the connector on the right side of the IPx
Office main unit. See
Software Authorization Management, page 8-16
5.
Verify that the IMC8 flash memory card and the compact flash memory disk
have been inserted into their respective drives located on the front panel of the
IPx Office unit. See
IMC8 Flash Memory Card, page 8-35
6.
Attach the Program Interface (PI) device cable to the KB0 programming port
connector on the front panel of the IPx Office unit. Verify that the PI device is
configured to match the data rate, word length, parity, and stop bits of KB0.
Default settings for KB0 are
9600 bps, 8 data bit, no parity, and 1 stop bit
.
7.
Turn ON the power switch on the PS Office power supply on the rear panel of
the IPx Office unit.
...................................................................................................
1
Activating and Initializing the Control Card
Содержание Coral IPx Office
Страница 2: ......
Страница 4: ......
Страница 25: ...xxi Figure 11 10 WiFi Antenna Removal 11 18...
Страница 26: ......
Страница 28: ......
Страница 36: ...1 8 Introduction Coral IPx Office Installation Manual About this Manual 1 NOTES...
Страница 44: ......
Страница 52: ...2 8 Hardware Installation Procedure Coral IPx Office Installation Manual Site Inspection 2 NOTES...
Страница 96: ......
Страница 106: ...3 10 Initial Power up Tests Coral IPx Office Installation Manual Common Control Test 3 NOTES...
Страница 120: ...3 24 Initial Power up Tests Coral IPx Office Installation Manual Completing the Installation 3 NOTES...
Страница 122: ......
Страница 128: ...4 6 Software Installation Procedure Coral IPx Office Installation Manual Generic Feature Software Upgrade 4 NOTES...
Страница 138: ......
Страница 144: ...5 6 External Connections Coral IPx Office Installation Manual Main Distribution Frame MDF 5 NOTES...
Страница 182: ......
Страница 232: ...6 50 System Description Coral IPx Office Installation Manual System Configuration Options IPx Office 6 NOTES...
Страница 234: ......
Страница 258: ...7 24 Power Supply Coral IPx Office Installation Manual PS Office DC Power Supply Unit 7 NOTES...
Страница 260: ......
Страница 286: ...8 26 Common Control Cards Coral IPx Office Installation Manual MCB Office Card Main Control Board 8 NOTES...
Страница 302: ...8 42 Common Control Cards Coral IPx Office Installation Manual Compact Flash Disk 8 NOTES...
Страница 310: ...8 50 Common Control Cards Coral IPx Office Installation Manual DBM Card 8 NOTES...
Страница 312: ......
Страница 372: ...9 60 Shared Service Cards Coral IPx Office Installation Manual VoIP Media Gateway MG 9 NOTES...
Страница 382: ...9 70 Shared Service Cards Coral IPx Office Installation Manual Data Serial Ports RS 232E KB0 KB1 KB2 KB3 9 NOTES...
Страница 414: ...9 102 Shared Service Cards Coral IPx Office Installation Manual Accessory or Alarm Relay 3 Major Minor Alarm 9 NOTES...
Страница 420: ......
Страница 488: ......
Страница 494: ...11 8 System Networking Coral IPx Office Installation Manual NTU Office Card Description 11 NOTES...
Страница 509: ......