T G W S IP -F X S /F S O G a te w a y S e rie s
User Manual
Tadiran Telecom
39
TGW16/24-2G, TGW16/24-3G, TGW96-2G Fax Configuration Interface
Figure 2-12
Table 2-11
Fax Configuration Parameters
Name
Description
Initial offer
Codec
Click
Edit
, go to
Basic
>
System
page to configure. For details, see 2.2.4 System.
RTP port Min.
Click
Edit
, go to
Advanced
>
Media stream
page to configure. For details, see 2.6.5 Media
RTP port Max.
Click
Edit
, go to
Advanced
>
Media stream
page to configure. For details, see 2.6.5 Media
Fax configuration
Transport mode
The device supports two fax modes: T.38 and G.711 transparent transmission.
When fax messages are received or sent through an analog trunk, the G.711 transparent
transmission mode is required. When fax messages are received or sent through an IP trunk, a
T.38 or a G.711 transparent transmission mode needs to be selected according to an actual
requirement and the mode supported by the IP phone operation platform. If both T.38 and G.711
transparent transmission modes are supported, T.38 is recommended because it is more stable.
Enable G.711 pass-through according to the your device model:
TGW4/TGW8: Select
G.711 pass-through
in this area.
TGW16/24, TGW16/24-2G, TGW96-2G: Select
G.711
in this field, and then select
Pass-through
.
Adjustable parameters when G.711 pass-through is enabled (default values are recommended):
Содержание aeonix TGW4