5.5
LIMITS OF USE AND TECHNICAL DATA
Power supply voltage
VAC
230
Power supply frequency
Hz
50
Insulation class
H
Degree of protection
IP
44
Appliance class
II
Ambient temperature (MIN - MAX)
°C
+0 -+40
Liquid temperature
°C
-10 to +110
MAX Relative humidity conditions
%
≤ 95
MAX operating pressure
bar/MPa
10 / 1.0
Suction inlet pressure
(1)
with liquid temp. 50°C
bar/MPa
0.3 / 0.03
Suction inlet pressure
(1)
with liquid temp. 95°C
bar/MPa
1.0 / 0.10
Suction inlet pressure
(1)
with liquid temp. 110°C
bar/MPa
1.5 / 0.15
Specific EEI
(2)
IEE
≤ 0.22
Mass
kg
3.5
(1)
To avoid cavitation noise, the minimum pressures on the suction inlet must be strictly complied with.
(2)
The most efficient reference parameter is EEI ≤ 0.20
TAB. 7
(Limits of use and technical data)
5.6
SOURCE OF ENERGY SUPPLY
The circulator is powered by the following energy source:
Single-phase electric current 230 VAC – 50 Hz.
5.7
EMISSIONS
5.7.1 SOUND PRESSURE
The maximum sound pressure level emitted by the pump when in operation is
<43 dB(A)
.