background image

iWorx® CSM1

502-045, Effective: July 25, 2013

© 2013 Taco Electronic Solutions, Inc.

APPLICABLE DOCUMENTATION

See the table below for additional documentation that may be applicable to this controller.

Typical Use

REPRESENTATIONS AND WARRANTIES

This Document is subject to change from time to time at the sole discretion of Taco Electronic Solutions, Inc. All 
updates to the Document are available at www.taco-hvac.com. When installing this product, it is the reader’s responsi-
bility to ensure that the latest version of the Document is being used. 

Description

Audience

Purpose

iWorx® Chilled Beam Sensor 
Module Application Guide, 

Docu-

ment No. 001-4128

– Application Engineers
– Wholesalers
– Contractors

Provides specific application information about the Chilled 
Beam Sensor Module, including sequence of operation and 
configuration information.

iWorx® LCI Application Guide

Document No. 505-002

– Application Engineers
– Installers
– Service Personnel
– Start-up Technicians
– End user

Provides instructions for setting up and using the iWorx® 
Local Control Interface.

http://www.iWorxWizard.com

– Application Engineers
– Wholesalers
– Contractors

An on-line configuration and submittal package generator 
based on user input. Automatically generates bill of materi-
als, sequence of operations, flow diagrams, wiring diagrams, 
points and specifications.

Additional Documentation

LonWorks FTT-10A Free Topology Transceiver User’s Guide,

 published by Echelon Cor-

poration. It provides specifications and user instructions for the FTT-10A Free Topology 
Transceiver. Information is also available at the following web site: www.echelon.com/
support/documentation/manuals/transceivers.

Содержание iWorx CSM1

Страница 1: ...stallation Guide 4 General 4 Static Electricity 4 FCC Compliance 4 Before Installing 5 About this Document 5 Inspecting the Equipment 5 What is Not Included with this Equipment 5 Equipment Location 5...

Страница 2: ...re measurement Outside air humidity measurement Supply water temperature measurement Inside humidity measurement Energy meter digital input for pulse counting Energy monitoring end of period digital i...

Страница 3: ...n information about the Chilled Beam Sensor Module including sequence of operation and configuration information iWorx LCI Application Guide Document No 505 002 Application Engineers Installers Servic...

Страница 4: ...connections in accordance with these instructions and in accordance with pertinent national and local electrical codes Use only copper conductors that are suitable for 167 F 75 C Static Electricity St...

Страница 5: ...d humidity within the ranges specified for this equipment The equipment must be installed within 500 feet of all input peripherals smoke detectors sensors etc that are con nected to the equipment Sele...

Страница 6: ...encil mark the mounting locations on the panel 3 Using a small drill bit pre drill the mounting holes 4 Using two 6 pan head screws mount the controller to the panel 5 Wire the controller See Routing...

Страница 7: ...risk of electrical shock and may increase the possibility of interference with radio TV reception For best performance connect the power supply common terminal T38 to the same external point as the g...

Страница 8: ...he adjacent common T4 The thermistor used must be 10K Precon Type III Chilled Supply Water Temperature CSWT To connect the Chilled Supply Water Temperature thermistor to the unit attach one wire from...

Страница 9: ...thermistor Energy Monitor End of Interval Normally open Dry contact 5 Volts DC Max Unit Enable Normally open closed when active Dry contact 5 Volts DC Max Recommended Sensor Wire Maximum Length 500 fe...

Страница 10: ...s of the controller s LEDs in the order they appear from left to right on the unit LED Indication Status Solid green when running and configured by an LCI networking Flashing green when running and NO...

Страница 11: ...firmware version number A complete description of difficulties encountered Problem Solution Controller is not running and Status LED is not illuminated No power to controller Verify the voltage on th...

Страница 12: ...red by this warranty TES products are not intended for use to sup port fire suppression systems life support sys tems critical care applications commercial aviation nuclear facilities or any other app...

Отзывы: