Taco Comfort Solutions Hot-LinkPlus HLPE-1 Скачать руководство пользователя страница 1

Application:

The Taco 

Hot-LinkPlus

TM

System

for Domestic Hot Water

recirculation ensures instant hot water comfort at showers

and  faucets.  By  supplying  fresh  hot  water  to  the  fixtures

while  returning  the  “cooled”  hot  water  back  to  the  water

heater through the cold line, it also saves thousands of gal-

lons  of  wasted  water  per  year.  The  average  family  can

achieve yearly savings of up to 12,000 gallons of water nor-

mally wasted down the drain while waiting for hot water.

High Quality Features:

The 

Hot-LinkPlus System

includes a Taco circulator des-

igned specifically for use with the Taco Hot-Link Valve. The

circulator and valve are suitable for most residential homes

with hot water supply lines up to 100 feet.
The unique 

Hot-Link Valve

is the key to the system. Made

of durable high temperature polymer, it creates an easy-to-

install return loop through the cold line from the furthest fix-

ture back to the water heater. An integral thermal sensor

disc closes when hot water reaches the valve. An internal

flow check prevents cold water from backing into the hot

line. Stainless steel braided flex hoses complete the instal-

lation.

Installing the Hot-LinkPlus System Circulator:

1. Follow  all  local  plumbing  and  electrical  codes  when

installing the 

Hot-LinkPlus System

.

2. Shut off cold water supply valve to water heater.
3. Open a hot water faucet in the house to drain the hot

water line.

4. Open water heater drain valve located at the bottom of

tank to drain remaining hot water from the lines. It is not

necessary to drain the entire tank.

5. Disconnect hot water supply line at water heater outlet

nipple.

6. Install one 

3

4

" tailpiece of the union adapter provided to

the water heater outlet. Apply pipe dope or Teflon tape

to all male threads as required.

7. Install  the  other 

3

4

"  union  tailpiece  to  the  pump  inlet

connection. Be  sure  flow  arrow  located  on  the  pump

casing is in the proper direction. See diagram.

8. Install  the  stainless  steel 

Hot-LinkPlus

circulator  by

connecting the union halves. Circulator motor must be

in the horizontal position.

9. Reconnect the hot water supply line to circulator outlet.

10. Open supply valve to water heater. Let water run until all

air is purged from lines. Check for any leaks. If leaks are

detected, close supply valve and tighten all connections.

11. Shut off open hot water faucet.

Instruction Sheet

Hot-LinkPlus

TM

System for Domestic Hot Water Recirculation

102-507

SUPERSEDES: New

EFFECTIVE: August 25, 2015

Plant ID# 001-4239

CAUTION:  Do  not  run  circulator  dry.

Permanent damage may result and will void

warranty.

CITY WATER

SUPPLY

Cold

Additional Hot-LinkPlus

Valve locations

Hot

Cold
Inlet

Water

Heater

HOT WATER LINE

A typical

installation

with a

Mixing Valve

Hot-LinkPlus

Circulator

COLD WATER LINE

Cold

Hot

The best location
is furthest fixture

from hot water heater

Shut-Off

Valve

Shut-Off

Valve

1/2"

1/2"

Use (2) existing 3/8" x 1/2"
female to female flex lines

(2) new 1/2" x 1/2"

Taco® supplied flex lines

(female to female)

Hot-LinkPlus   includes (2)

plastic wall anchors

and screws

DIAGRAM IS FOR 

DEMONSTRATION ONLY

TM

Hot-LinkPlus

Circulator

DIAGRAM IS FOR 

DEMONSTRATION ONLY

WARNING: To  avoid  electrical  shock,  disconnect  the

power  supply  to  the  circulator  and  the  main

electrical unit.

WARNING: 1. Circulator must be installed on and support-

ed by the circulation piping.

2. The addition of unions on both the suction

and  discharge  side  of  the  circulator  is

recommended.

A Taco resource – saving product

Содержание Hot-LinkPlus HLPE-1

Страница 1: ... one 3 4 tailpiece of the union adapter provided to the water heater outlet Apply pipe dope or Teflon tape to all male threads as required 7 Install the other 3 4 union tailpiece to the pump inlet connection Be sure flow arrow located on the pump casing is in the proper direction See diagram 8 Install the stainless steel Hot LinkPlus circulator by connecting the union halves Circulator motor must ...

Страница 2: ...se or Smart mode NOTE The circulator must be installed and supported by the circulation piping WARNING All local plumbing and electrical codes should be followed when installing this product WARNING Risk of electrical shock This pump is sup plied with a grounding conductor and grounding type attachment plug To reduce the risk of shock be cer tain that it is connected only to a properly grounded gr...

Страница 3: ...f Valve 1 2 Male 2 New 1 2 x1 2 Taco supplied flex lines female x female Use 2 existing female x female flex lines 1 2 Male Hot Link includes 2 plastic wall anchors screws Cold 1 2 3 8 Male 3 8 Male 1 2 HOT COLD Hot LinkPlus Trouble Shooting SYMPTOM POSSIBLE CAUSE SERVICE TIP No Hot Water Clogged filter screen Close angle stop valves beneath sink Open hot and cold faucets to drain line of pressure...

Страница 4: ... for use with a Taco product or part or for any application restrictions consult the applicable Taco instruction sheets or contact Taco at 401 942 8000 Taco reserves the right to provide replacement products and parts which are substantially similar in design and functionally equivalent to the defective product or part Taco reserves the right to make changes in details of design construc tion or a...