Signal level LEDs

Signal LEDs are updated at a ~4 second interval.

Behavior

Meaning

All signal LEDs are off

The device is currently operating in AP mode, or the device is powered off.

The first LED is on & slowly blinking

The device is in station mode and is currently scanning.

All three LEDs are on & fast blinking

The device is currently updating its modem firmware.  This only happens at
boot after a firmware upgrade.

The first LED is on and not blinking

The device is in station mode and currently connected to an AP with low
signal strength.

The first two LEDs are on, not blinking

The device is in station mode and currently connected to an AP with
medium signal strength.

All three LEDs are on, not blinking

The device is in station mode and currently connected to an AP with high
signal strength.

Ethernet port LEDs

2.5G ETH0

: The link light will turn on when a link is established, and the power light will turn on once the device is

supplied with power. 

1G ETH1

The link light will turn on and blink when a link is established, and the PoE out light will turn on when PoE out is

enabled in software.

Powering your device

Input Power

i

 

 Important Notes

The input power should be 48VDC and a minimum of .5A (24W) is recommended.  
-48VDC is 

not

 currently supported.

TNA-30x devices can 

not

 be powered by active PoE (802.3at, etc).

The TNA-30x can be powered two ways, either via:

1.  The Power over Ethernet (PoE) port or via
2.  The DC input terminal.  

Содержание TNA-30 Series

Страница 1: ...link Updating firmware Resetting your device Mounting your device i Note Please be patient the first time you power on your device as it make take more time than normal to boot up while the device fla...

Страница 2: ...nal strength The first two LEDs are on not blinking The device is in station mode and currently connected to an AP with medium signal strength All three LEDs are on not blinking The device is in stati...

Страница 3: ...hould be taken to ensure there is adequate power supply to power both the TNA 30x and the secondary device The supplied PoE injector may not be adequate to power both devices and may result in unstabl...

Страница 4: ...I navigate to the wireless 60 GHz radio settings and input the new settings on both devices and subsequent client radios Click save to apply the changes If the channel width or operation mode has been...

Страница 5: ...ingle carrier PHY for transmitting data Single carrier PHYs are more susceptible to destructive reflections than some other methods such as OFDM I m still having trouble with my link what do I do next...

Страница 6: ...script firmware upgrades via the API Reference the Tachyon Networks RESTful API https tachyon networks freshdesk com support solutions articles 67000659777 tna 30x restful api specs article for more i...

Страница 7: ...12 12 TNA 30x Operating Manual Support Learning Portal https tachyon networks freshdesk com support solutions articles 67000670226 tna 30x operating manual 7 10 Mounting your device Wall mounting ins...

Страница 8: ...not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to compl...

Страница 9: ...stance from the antenna The antenna should be kept away from the face and eyes Use of non approved antennas batteries and accessories causes the radio to exceed the FCC ISEDC RF exposure guidelines An...

Страница 10: ...26 09 2023 12 12 TNA 30x Operating Manual Support Learning Portal https tachyon networks freshdesk com support solutions articles 67000670226 tna 30x operating manual 10 10...

Отзывы: