AW20 Series Weighing Scale Operation Manual

- 1 -

1. PRECAUTIONS

WARNING

DISCONNECT ALL POWER TO THIS UNIT BEFORE

INSTALLING, CLEANING, OR SERVICING. FAILURE TO DO SO

COULD RESULT IN BODILY HARM OR DAMAGE THE UNIT.

CAUTION

Permit only qualified persons to service the instrument

Before connecting or disconnecting any components, remove the power.

Failure to observe these precautions bodily harm or damage to or destruction of the

equipment.

Содержание AW20

Страница 1: ...Operation Manual AW20 Weighing Scale A1...

Страница 2: ......

Страница 3: ...Log in 13 5 3 Zero Setting 14 5 4 Tare 14 5 4 1 Semi automatic tare 14 5 4 2 Automatic tare 14 5 4 3 Pre set tare 15 5 5 Weighing Operation 17 5 6 Weighing Units Conversion 18 5 7 PLU Information Stor...

Страница 4: ...its setting for target percentage 36 5 12 5 Tolerance Checking Mode 37 5 13 Backlight Setting 38 5 14 Auto Power Off 39 5 15 Animal Weighing 40 5 16 Peak Hold 41 6 CALIBRATION 43 6 1 Normal Calibratio...

Страница 5: ......

Страница 6: ...LING CLEANING OR SERVICING FAILURE TO DO SO COULD RESULT IN BODILY HARM OR DAMAGE THE UNIT CAUTION Permit only qualified persons to service the instrument Before connecting or disconnecting any compon...

Страница 7: ...this device Verify the local voltage and receptacle type are correct for the scale Only use original adaptor other could cause damage to the scale Pluggable equipment must be installed near an easily...

Страница 8: ...t percentage weighing tolerance checking Accumulation mode with manual accumulation auto load accumulation and auto unload accumulation Up to 300 PLUs capacity 8 direct PLUs supported to display alpha...

Страница 9: ...AW20 Series Weighing Scale Operation Manual 4 2 2 Over View 1 2 3 4 5 6...

Страница 10: ...ption 1 RJ45 Support 10M 100M Ethernet 2 USB2 0 For USB disk scanner data transfer don t use for charging other device 3 RS232 For connecting computer printer alarm light Remote display Second platfor...

Страница 11: ...cale later Inspect the scale for damage Make sure all components are included 1 Scale 2 Adaptor 3 Manual 4 Stainless steel pan 3 2 Installation Remove transport lock from bottom of the scale base Plac...

Страница 12: ...will flicker on the display Approximately 30 minutes of instrument usage are left afterwards it will shut off automatically Please use the supplied battery charger for charging the battery immediatel...

Страница 13: ...ghing Scale Operation Manual 8 4 Disconnect the lithium battery connector 4 5 Replace the new lithium battery and connect the battery connector 6 Put the foam next to the battery and close the battery...

Страница 14: ...Unit Weight key Used to store the known average piece weight of item Long press to change the average piece weight value of item Sampling key Used to enter the counting operation Product key Used to r...

Страница 15: ...ighing mode Tare key Used to perform a tare function Subtracts weights Limit key Used to enter check weighing mode Long press to set HI and Low limits Accumulation key Used to store the accumulation w...

Страница 16: ...ght Indicates scale is displaying the net weight Tare weight Indicates scale is displaying the tare weight Gross weight Indicates scale is displaying the gross weight Lack of unit weight Indicates pie...

Страница 17: ...AW20 Series Weighing Scale Operation Manual 12 Total Displays accumulated total weight Range Display Bar Displays the range of capacity...

Страница 18: ...s on it may be asked to input the account and password to log in 2 Input the account by using numeric keys press key to confirm 3 Input the password by using numeric keys press key to confirm 4 Displa...

Страница 19: ...It will be shown with a minus value 4 This Tare value can be cleared by pressing key when there is no load on the platter This tare entry cannot take place if the platter is in in motion 5 4 2 Automa...

Страница 20: ...are window will be active 2 Using numeric keys to input the tare value 3 Press key to confirm the preset tare value appears Indirect pre set tare The scale has a pre set tare function it can be combin...

Страница 21: ...ct PLU list 2 Display will be show selected product name number pre tare value 3 Place the item on the pan and wait to get weight stable display show net weight 4 Remove item from the pan the net wind...

Страница 22: ...4 Remove item from the pan the net window show negative value 5 Press key to clear tare value 5 5 Weighing Operation Switch on the scale display show normal weighing mode Load the weight on the pan di...

Страница 23: ...lative units symbol will turn on in the display To enable the weighing units please see parameter 2 ADVANCED SETTINGS 1 DISPLAY UNIT 1 Press key to enter setup menu 2 Press key to select 2 ADVANCED SE...

Страница 24: ...r to setup menu 2 PRODUCT INFO 2 ADD EDIT PRODUCT Operation 1 Press key to enter setup menu 2 Press key 2 times to select 2 PRODUCT INFO 3 Press key to enter 4 Press key to select 2 ADD EDIT PRODUCT 5...

Страница 25: ...ng the current product number name or by selecting a new PLU key will be clear existing PLU number name automatically 5 7 3 Store Direct PLU information 1 Press key to recall the indirect PLU informat...

Страница 26: ...AW20 Series Weighing Scale Operation Manual 21 5 7 4 Recall direct PLU In normal weighing mode press M key selected from to to recall direct PLU...

Страница 27: ...tion scale should be stable and return to zero sampling available only when weight more than 20d 5 8 1 Manual Sampling for counting procedure 5 8 1 1 Simple Sampling Make sure platter empty and displa...

Страница 28: ...r weight and number of items will be increased Remove the items the average piece weight will remain stored in memory for the next counting of similar pieces Press and hold key to back to normal weigh...

Страница 29: ...ample window will be active Using numeric keys to input the count number eg 10 Press key to confirm display show dotted line The average piece weight of item will be calculated and then the number of...

Страница 30: ...ribed Press and hold key to back to normal weighing mode Note The weighing may be amended on the basis of greater numbers of samples improves the accuracy of counting large quantities 5 8 2 To input t...

Страница 31: ...ly add further parts whose number is smaller than that of the first reference determination For each reference optimization the average piece weight is newly calculated As the additional pieces increa...

Страница 32: ...rcentage of 0 47kg 100 Place 0 210kg weight on the platform display will be show 44 7 as per the percentage of 0 470kg 100 Press and hold key to back to normal weighing mode The weighing may be amende...

Страница 33: ...mulation available only when weight more than 20d 5 10 1 Manual Accumulation 1 Place the load on the platform the weight display will be show the net weight 2 Press key when STABLE indicator on 3 Tota...

Страница 34: ...lay get zero and stable then place the second weight 5 It can continue until the memory gets fully 5 10 3 Auto Unload Accumulation To enable the auto unload accumulation please refer to parameters 2 A...

Страница 35: ...ation records will be show 3 Press key or key to scroll up or scroll down to view the records 4 If connected with printer press key to print out the accumulation records 5 Press key to back to normal...

Страница 36: ...tion and No Printing If connected with printer the data will be print out in accumulation mode see parameters 2 ADVANCED SETTINGS 7 ACCUMULATION 3 PRINT EVERY RECORD NO MANUAL Load the weight after st...

Страница 37: ...s NOTE When switching between products with counting modes there will be warning window to clear the total The user has to clear the total by pressing long CE from the ACC report 5 11 Printing 5 11 1...

Страница 38: ...ighing goods according to a target quantity or target weight or target percentage within specified tolerances With this function one can also check if the weighing good is within a defined tolerance r...

Страница 39: ...lerance range Target quantity target weight target percentage exceeds maximum tolerance limit 5 12 2 Limits setting for target weight 1 Press and hold key to enter limits setting in Normal weighing mo...

Страница 40: ...ion enter zero in both limits 5 12 3 Limits setting for target quantity 1 To enter counting mode by sampling or inputting the known unit weight of item 2 Press and hold key to enter limits setting 3 T...

Страница 41: ...imits 5 12 4 Limits setting for target percentage 1 Press key to enter percentage weighing in normal weighing mode 2 Press key to enter limits setting 3 The lower limit value in the display will be ac...

Страница 42: ...ight more than 20d The function is not valid when one enters a lower limit greater than the upper limit When lower limits are the same with upper limits display only shows one set value 5 12 5 Toleran...

Страница 43: ...ter to system settings 3 Press key until to select the backlight 4 Press key to enter the menu 5 Press key to change the setting LOW Backlight turn to be low light NORMAL Backlight turn to be medium l...

Страница 44: ...riod of time in minutes Operation 1 Press key to enter setup menu 2 Press key to enter to system settings 3 Press key until to select the power sleep 4 Press key to enter the menu 5 Press key to chang...

Страница 45: ...5 Press key to enter settings 6 Press key to change the settings until display show ANIMAL WEIGH 7 Once selected the animal weighing mode it could enter 5 ANIMAL WEIGH sub menu to set the relative ran...

Страница 46: ...ears with a beep sound the final weight will be shown on the display The weight will be update when the load weight exceed the floating range and jump range To disable the animal weighing function it...

Страница 47: ...settings 6 Press key to change the settings until display show PEAK HOLD 7 Press key to confirm 8 Press key two times to exit the setup menu and back to peak hold weighing mode 9 The Peak indicator wi...

Страница 48: ...rameters 4 SCALE1 2 Calibration 1 Normal Calibration Before access to the parameter it need to press calibration switch locating back side of indicator in approval version Steps Remark 1 Press Key to...

Страница 49: ...the platter Better to use minimum 1 3 of the scale capacity 6 Press key to confirm The display will be show Please empty the scale 7 Remove the test weight from the scale 8 Press key to confirm The di...

Страница 50: ...g and Stainless Steel pan Interface RS232 RJ45 USB2 0 Optional RS485 WIFI Bluetooth analog output second platform Operation Temperature 10 C 40 C 14 F 104 F Power AC Adaptor 12V 2500mA Optional Rechar...

Страница 51: ...inless Steel pan Interface RS232 RJ45 USB2 0 Optional RS485 WIFI Bluetooth analog output second platform Operation Temperature 10 C 40 C 14 F 104 F Power AC Adaptor 12V 2500mA Optional Rechargeable Li...

Страница 52: ...ck the load cell connectors Sample low Percentage Error Please check input data must be 1 of full capacity Lack of unit weight Check unit weight entry data must be 0 1d Lack of sample Check counting s...

Страница 53: ...device 4 Do not use organic acid alkaline solutions scouring powders or plastic dissolving cleaning agents for cleaning 5 Do not spray directly on the device 6 Avoid strong pressure or scratching the...

Страница 54: ...ibration Check pan is installed correctly Verify installed in an acceptable location Cannot use Full Capacity Overload Stopper touching pan support or bottom of the load cell Transportation lock not r...

Страница 55: ......

Страница 56: ...TScale Electronics Mfg Kunshan Co Ltd 99 Jingwei Road Kunshan Jiangsu China Tel 86 512 57669080 www t scale com...

Отзывы: