17
Telephony Basic Settings
Factory Settings on Delivery
Factory Settings on Delivery
The following basic settings and features are active on delivery. We recommend that you configure
Comfort Pro S to suit your individual requirements before using it (see
N
Note:
The basic settings apply to the smallest version of Comfort Pro S, i.e., without
additional interface cards.
Telephony Basic Settings
■
The S
0
1 port is configured for multi-terminal access, the S
0
2 port for system access.
■
The 3 U
pn
-ports are configured for Comfort Pro P 300 system telephones with the call numbers 30 to 32.
■
The 4 a/b ports are configured for analogue devices with the call numbers 10 to 13.
■
Comfort Pro S is configured ready for use in Germany.
■
Analogue devices: The dialling mode (IWV or MFV) is automatically detected.
■
All corded terminals connected to the base module ring if there are incoming external calls.
■
The system PIN, for remote programmable call diversion for example, is set at “0000”.
Authorisations
The allocation of authorities regulates which functions a terminal on Comfort Pro S can use. These authorities
are configured for so-called user groups, to which users and their terminals are then assigned.
Three user groups are preset: “Administrators”, “Standard” and “Guests”. “Administrators” can access all
functions in Comfort Pro S and have unlimited configuration rights. Users in the “Guests” group can not
configure Comfort Pro S, may not make any external calls and can only use a limited range of Comfort Pro S
terminal functions. The “Standard” user group is well suited as a starting point for creating user groups for
normal users of the system (e. g. the staff members of a company) because of its default settings.