background image

50

Anhang / Appendix A3

Anhang / Appendix A3a

Standardanschluss / Standard connections

+

RISQUE DE CHOC ELECTRIQUE. NE PAS ENLEVER LES VIS!

SHOCK HAZARD. DO NOT OPEN!

ACHTUNG HOCHSPANNUNG!  NICHT ÖFFNEN!

HERFORD, GERMANY

M10

+

+

220 - 230 V~     50 - 60 Hz     2500 W

M10

Lautsprecher
Speaker

Hinweis:
Einstellung 

'Bi-Amping'

 auf 

OFF

.

Note:
Set 

'Bi-Amping'

 to 

OFF

.

Anhang / Appendix A3b

RISQUE DE CHOC ELECTRIQUE. NE PAS ENLEVER LES VIS!

SHOCK HAZARD. DO NOT OPEN!

ACHTUNG HOCHSPANNUNG!  NICHT ÖFFNEN!

HERFORD, GERMANY

M10

+

+

+

220 - 230 V~     50 - 60 Hz     2500 W

M10

Lautsprecher
Speaker

Hinweis:
Einstellung 

'Bi-Amping'

 auf 

OFF

.

Note:
Set 

'Bi-Amping'

 to 

OFF

.

Содержание M 10

Страница 1: ...V 1 0 Bestell Nummer Order No 9103 0426 DE UK BETRIEBSANLEITUNG USER MANUAL M 10 ...

Страница 2: ...2 ...

Страница 3: ...3 Seite Page Deutsch 4 English 26 Anhang Appendix A Anschlussbilder Wiring diagrams 48 Anhang Appendix B Technische Daten Technical specifications 53 ...

Страница 4: ...wo irgend möglich auf Kunststoffe insbesondere auf PVC als Konstruktionselement Statt dessen wird auf Metalle oder andere unbedenkliche Materialien zurückge griffen die einerseits gut recyclebar sind und andererseits eine sehr gute elektrische Abschirmung ergeben Durch unsere massiven Ganzmetallgehäuse wird eine Beeinträchtigung der Wiedergabequalität durch äußere Stör quellen ausgeschlossen Die v...

Страница 5: ...elemente 16 Aufstellung und Verkabelung 18 Auspacken 18 Aufstellung 18 Mechanische Entkopplung 18 Lautsprecher und Signalkabel 18 Netzkabel und Netzfilter 18 Röhren einsetzen 19 Sicherheitshinweise 21 Bestimmungsgemäßer Gebrauch 22 Gerätezulassung und Konformität mit EG Richtlinien 22 Pflege des Gerätes 22 Sonstiges Betriebsstörungen 23 Anhang Anschlussbilder 48 Technische Daten 53 ...

Страница 6: ...6 Technische Übersicht ...

Страница 7: ...d externen Lautsprecherkabel parallel und auch alle vier im M10 vorhandenen Lautsprecherrelais liegen parallel Dadurch ergibt sich ein extrem niedriger dynamischer Innenwiderstand und der Lautsprecher wird optimal bedämpft Das Resultat ist eine exzellente Kontrolle der Membranbewegungen größtmöglichen Kontrolle im Bassbereich und eine hervorragende Detailauflösung bei der Wiedergabe Netzteil Der M...

Страница 8: ...8 ...

Страница 9: ...9 Bedienung ...

Страница 10: ... einer Verzögerung von ca 1 Minute ab Hinweis Für die Kombination P10 M10 stehen im Zubehör programm spezielle 4 polige XLR Kabel mit integrierter Triggerleitung zur Verfügung Einschalten per Musiksignal Der M10 verfügt auch über eine signalgesteuerte Ein schaltautomatik die den M10 einschaltet sobald ein Musiksignal an einem seiner Eingänge anliegt Bleibt das Musiksignal aus schaltet der M10 mit ...

Страница 11: ...lossen ist High Current Diese LED signalisiert den Hochstrombetrieb High Current Mode des M10 siehe Kapitel High Current High Power Bedienelemente an der Rückseite STÖRUNG Sollte im Gerät den Lautsprecherkabeln oder den Lautsprechern eine Störung auftreten wird dies durch Aufleuchten oder Blinken dieser LED ange zeigt Hinweise zu möglichen Störungsursachen finden Sie im Kapitel Betriebsstörungen L...

Страница 12: ...t sprecherklemmen zur Verfügung Die beiden Ausgangs stufen des M10 können entweder parallelgeschaltet oder getrennt betrieben werden Bei getrenntem Betrieb spricht man auch vom Bi Amping da der M10 in dieser Betriebsart zwei praktisch unabhängige Verstärkerzweige zur Verfügung stellt Bi Wiring Wenn ein Lautsprecher mit Bi Wiring Anschluss zur Verfügung steht können Tiefton und Mittelhochton bereic...

Страница 13: ...t werden Alle anderen Taster wirken nicht auf den M10 V Anlage ein ausschalten Zum Einschalten den Taster kurz antippen so dass der Vorverstärker einschaltet Über den Vorver stärker wird sodann der M10 mit eingeschaltet Um die Anlage auszuschalten bitte den Taster so lange gedrückt halten bis alle Geräte der V Anlage in den Standby Betrieb abgeschaltet haben Der Vor Vollverstärker bzw Receiver sch...

Страница 14: ...14 ...

Страница 15: ... diesem Kapitel werden alle Dinge von grundsätzlicher Bedeutung für die Aufstellung und Inbetriebnahme beschrieben die nicht für den täglichen Umgang mit dem Gerät relevant sind die aber trotzdem vor dem ersten Gebrauch gelesen und beachtet werden sollten ...

Страница 16: ... Zubehör programm zur Verfügung Balanced II 3 pol symmetrische Signaleingänge Eingang für Vorverstärker mit symmetrischem Ausgang Die XLR Buchse ist mit der XLR Ausgangsbuchse des Vorverstärkers zu verbinden Hinweis Der M10 ist mit drei Eingangsvarianten Cinch XLR symmetrisch 3 pol XLR symmetrisch 4 pol ausge stattet Beim Anschluss darf jeweils nur eine An schlussvariante gewählt werden Die jeweil...

Страница 17: ...ieb mit sehr großer Lautstärke die hohen Ströme in den Leistungsendstufen zu einer Überhitzung und damit zum automatischen Abschalten durch die Schutzschaltung führen Es muss darauf geachtet werden dass die Anschluss klemmen fest verschraubt sind und keine Kurzschlüsse durch herausstehende Kabelreste entstehen Im Zubehörprogramm steht eine Auswahl hoch wertiger Kabel zur Verfügung die exakt auf di...

Страница 18: ...iese Schrauben vor Inbetriebnahme des Gerätes fest anziehen Mechanische Entkopplung Die Standfläche und der Untergrund auf dem hoch wertige HiFi Geräte aufgestellt werden haben einen nicht zu unterschätzenden Einfluss auf die erreichbare Klangqualität Die Standfläche sollte möglichst schwer stabil hart und eben sein Das Gerät ist mit den neuentwickelten Vibrations absorberfüßen ausgestattet Diese ...

Страница 19: ...19 Röhren einsetzen Zentrale Befestigungsschraube der Abdeckplatte lösen Erdungsschraube lösen und Abdeckung entfernen A B C Röhren einsetzen A B C auf Kennzeichnung am Röhrensockel achten ...

Страница 20: ...Gerätes wichtig Diese Schrauben vor Inbetriebnahme des Gerätes fest anziehen Zentrale Befestigungsschraube der Abdeckplatte anziehen ACHTUNG Erdungsschrauben sind für die Sicherheit des Gerätes wichtig Diese Schrauben vor Inbetriebnahme des Gerätes fest anziehen Das Gerät darf nicht ohne Röhrenabdeckung betrieben werden ...

Страница 21: ...nen Stellen Sie das Gerät frei auf und sorgen Sie für eine ungehinderte Luftzufuhr zum Gerät Legen Sie keine Gegenstände auf das Gerät Beachten Sie alle Angaben im Kapitel Aufstellung Lassen Sie das Gerät abkühlen bevor Sie es trans portieren oder es bewegen Stellen Sie das Gerät so auf dass es für Kinder unerreichbar ist Das Gerät darf nur vom qualifizierten Fachmann geöffnet werden Reparaturen u...

Страница 22: ...der Kraftstoffe enthalten können Vor der Wiederinbetriebnahme muss sichergestellt sein dass keine Kurzschlüsse an den Anschlussstellen be stehen und dass alle Anschlüsse ordnungsgemäß sind Gerätezulassung und Konformität mit EG Richtlinien Das Gerät entspricht im Originalzustand allen derzeit gültigen deutschen und europäischen Vorschriften Es ist zum bestimmungsgemäßen Gebrauch in der EG zuge las...

Страница 23: ...er verdrillen beschädigte Kabel austauschen Ursache 3 Übersteuerung durch schlechten Masse kontakt Abhilfe Eingangskabel abziehen und warten ob der ENDVERSTÄRKER wieder ein schaltet wenn ja dann Eingangskabel überprüfen und ggf austauschen Ursache 4 Netzstörungen Unterspannung Abhilfe Bei extremer Netzunterspannung bzw starken Störungen auf der Netzleitung schaltet der M10 selbstständig die Laut s...

Страница 24: ...24 ...

Страница 25: ...25 English ...

Страница 26: ... to health such as chlorine based cleaning agents and CFCs We also aim to avoid the use of plastics in general and PVC in particular in the design of our products Instead we rely upon metals and other non hazardous materials metal components are ideal for recycling and also provide effective electrical screening The robust all metal cases which we use offer a real and practical advantage since the...

Страница 27: ... wiring using the unit for the first time 40 Unpacking 40 Setting up 40 Mechanical de coupling 40 Loudspeaker and signal cables 40 Mains cables and mains filters 40 Insert Tubes 41 Safety notes 43 Approved usage 44 Approval and conformity with EC directives 44 Care of the unit 44 FCC Information to the user 44 General Trouble shooting 45 Appendix Wiring diagrams 48 Technical specifications 53 ...

Страница 28: ...28 Technical summary ...

Страница 29: ...el and all four loudspeaker relays present in the M10 also operate in parallel This results in extremely low dynamic internal resistance and optimum damping for the loudspeaker The outcome is excellent control of speaker cone travel maximum possible control in the bass range and superb detail resolution in music reproduction Mains section The M10 features a total of three independent mains power s...

Страница 30: ...30 ...

Страница 31: ...31 Operation ...

Страница 32: ... Note For the P10 M10 combination the accessory range includes special 4 pin XLR cables with integral trigger wire Switching on via the music signal The M10 also features a signal controlled automatic power on circuit which switches the M10 on as soon as a music signal is present at one of its inputs When the music signal ceases the M10 switches itself off again after a delay of about thirty minut...

Страница 33: ... a bi wiring arrangement High Current This LED indicates the M10 s high current mode see chapter High Current High Power Back panel controls PROBLEM If a problem occurs in the machine the loud speaker cables or the loudspeakers this LED lights up or is blinking to warn you of the problem Notes on fault finding can be found in the chapter entitled Trouble shooting LOUDSPEAKER OUTPUT This LED lights...

Страница 34: ...ed separately When operated separately the amplifier is said to be in bi amping mode as the M10 then provides what in practice is two independent amplifier circuits Bi Wiring If your system includes loudspeakers fitted with bi wiring terminals the bass and mid range drivers can be con nected to the M10 s two pairs of output terminals using separate cables Bi wiring see Appendix A3c Bi Amping ON In...

Страница 35: ...ns are without function for the M10 Switching a V system on and off To switch the system on press the button briefly in order to switch the pre amplifier on The M10 is then switched on automatically via the pre amplifier To switch the system off hold the button pressed in until all the devices in the V system have switched to stand by mode The pre amplifier integrated amplifier or receiver is the ...

Страница 36: ...36 ...

Страница 37: ...tes This section describes all those matters which are of fundamental importance when setting up and first using the equipment This information is not relevant in daily use but you should nevertheless read and note it before using the equipment for the first time ...

Страница 38: ...al XLR cables with 4 pin plugs and a control wire for the trigger signal Balanced II 3 pin symmetrical signal inputs Input for pre amplifiers with symmetrical output The XLR socket is connected to the pre amplifier s XLR output socket Note The M10 is equipped with three variants of input socket Cinch XLR symmetrical 3 pin XLR symmetrical 4 pin When connecting equipment only one variant may be sele...

Страница 39: ...olume produces high currents in the power output stages which can lead to overheating This in turn trips the protective circuit which switches the amplifier off automatically It is important to ensure that the terminal clamps are firmly screwed down and that no short circuits can occur through wire whiskers at the terminals A selection of excellent cable is available as accessories matching to the...

Страница 40: ...rmly Mechanical de coupling The quality and characteristics of the base on which your high quality Hi Fi equipment stands define the limits of sound quality which can be achieved The base surface should be as heavy rigid hard and level as possible This amplifier is supplied with the new vibration absorbing feet This feet feature internal damping qualities which effectively de couple the unit from ...

Страница 41: ...41 Insert Tubes Loosen the central fixing screw for cover plate Loosen grounding screw and remove tube cover A B C Insert tubes A B C observe marking on tube socket ...

Страница 42: ... These screws must be tightened firmly before switching the unit ON Fasten the central fixing screw for cover plate ATTENTION Grounding screws are essential for the safety of this device These screws must be tightened firmly before switching the unit ON For electrical safety Device may not be operated without tube cover ...

Страница 43: ...ion and ensure that air can flow to and around it completely unhindered Do not place any object on the amplifier Note the recommended points in the section Setting up Allow the amplifier to cool down before you move or transport it Set up the amplifier in a position where children cannot touch it The case should only be opened by a qualified specialist technician Repairs and fuse replacements shou...

Страница 44: ... must be present on the outside of the unit and must be clearly legible The serial number is a constituent part of our conformity declaration and therefore of the approval for operation of the device The serial numbers on the unit and in the original documentation supplied with it in particular the inspection and guarantee certificates must not be removed or modified and must correspond Infringing...

Страница 45: ...d cable Cause 3 Excessive levels due to poor earth contact Remedy Unplug input lead and wait to see if the power amplifier switches on again automatically If so check and replace input leads if necessary Cause 4 Mains interference low voltage Remedy If the mains voltage should fall to an extreme level or if powerful interference should occur in the mains cables the M10 automatically switches the l...

Страница 46: ...46 ...

Страница 47: ...47 Anhang Appendix ...

Страница 48: ...K HAZARD DO NOT OPEN ACHTUNG HOCHSPANNUNG NICHT ÖFFNEN HERFORD GERMANY M10 Gnd Control Signal Signal Signal Gnd Signal R R AUX PH AUX2 AUX1 TUNER DISC IN RECORDER OUT TASI RLINK RS 232 OUT R OUT L PHONES BAL OUT R L 220 230 V 50 60 Hz 120 VA T630mA L L MADE IN HERFORD GERMANY GND 220 230 V 50 60 Hz 2500 W 220 230 V 50 60 Hz 2500 W M10 rechts right M10 links left P10 Empfohlene Anschlussvariante An...

Страница 49: ...CHTUNG HOCHSPANNUNG NICHT ÖFFNEN HERFORD GERMANY M10 Gnd Control Signal Signal Signal Gnd Signal RISQUE DE CHOC ELECTRIQUE NE PAS ENLEVER LES VIS SHOCK HAZARD DO NOT OPEN ACHTUNG HOCHSPANNUNG NICHT ÖFFNEN HERFORD GERMANY M10 Gnd Control Signal Signal Signal Gnd Signal 220 230 V 50 60 Hz 2500 W 220 230 V 50 60 Hz 2500 W P10 M10 rechts right M10 links left Anschluss Schema M10 mit Vorverstärker P10 ...

Страница 50: ...FORD GERMANY M10 220 230 V 50 60 Hz 2500 W M10 Lautsprecher Speaker Hinweis Einstellung Bi Amping auf OFF Note Set Bi Amping to OFF Anhang Appendix A3b RISQUE DE CHOC ELECTRIQUE NE PAS ENLEVER LES VIS SHOCK HAZARD DO NOT OPEN ACHTUNG HOCHSPANNUNG NICHT ÖFFNEN HERFORD GERMANY M10 220 230 V 50 60 Hz 2500 W M10 Lautsprecher Speaker Hinweis Einstellung Bi Amping auf OFF Note Set Bi Amping to OFF ...

Страница 51: ...rrent On or High Current Auto according to the loudspeaker s requirements Set Bi Amping to OFF Anhang Appendix A3d Bi Wiring und and Bi Amping RISQUE DE CHOC ELECTRIQUE NE PAS ENLEVER LES VIS SHOCK HAZARD DO NOT OPEN ACHTUNG HOCHSPANNUNG NICHT ÖFFNEN HERFORD GERMANY M10 220 230 V 50 60 Hz 2500 W M10 Lautsprecher Speaker Verbindungsbrücken entfernen Remove links Hinweis Einstellung auf High Current...

Страница 52: ...52 ...

Страница 53: ...mpfindlichkeit UA 25 Veff Input sensitivity UO 25 Veff 540 mV Netzteilsiebung PWR Supply reservoir capacity 180 000 µF Netzanschluss PWR requirement Siehe Rückwand see print on the back panel Max 2500 W Leistungsaufnahme Power consumption Standby OFF 0 4 W Zum Lieferumfang gehören Supplied with amplifier Netzkabel RLINK Kabel mains lead RLINK cable Inbus Schlüssel für Erdungsschraube am Röhrenabde...

Страница 54: ... elektroakustik GmbH Co KG Herford Deutschland Germany ...

Отзывы: