Operating mode button
The operating mode button is used to switch the loud-
speaker output on and off, and to switch the VU meter
display.
Switching the speakers on and off
A brief press on the operating mode button switches the
loudspeakers on and off.
Changing the VU meter display
Repeated long presses on the operating mode button
cycle through the
M10
’s various VU meter displays.
>
VU meter off
>
Momentary value (fast)
>
Average value (slow)
>
Average value with peak indicator
Screen
The screen area of the
M10
consists of two zones: the
top area (VU meter) can display the momentary output
level of the
M10
for checking purposes; the bottom area
(status display) shows the machine’s current mode of
operation by means of LED indicators.
Status display
The following table provides information on the meaning
of the LED indicators in the status display area:
Bi-amping
When this LED is lit, the two output stages of the
M10
are set to operate separately, rather than in parallel.
For more information please see the section entitled
“Bi-amping , Back panel controls”.
Note:
Bi-amping mode is suitable exclusively for loud-
speakers designed for bi-amping and bi-wiring. For
this reason bi-amping should only be switched on if
the loudspeaker is actually connected using a
bi-wiring arrangement.
High Current
This LED indicates the
M10
’s high-current mode (see
chapter “High Current / High Power, Back panel
controls”).
PROBLEM
If a problem occurs in the machine, the loud-speaker
cables or the loudspeakers, this LED lights up or is
blinking to warn you of the problem.
Notes on fault-finding can be found in the chapter
entitled “Trouble-shooting”.
LOUDSPEAKER OUTPUT
This LED lights up when the loudspeaker is switched
on.
The LED flashes during the power-on delay, and
when the protective circuit has switched the loud-
speaker off due to a technical problem.
ON / OFF operating mode
This LED lights up when the
M10
is switched on.
A
AUTOMATIC
This LED lights up when the
M10
is in AUTOMATIC
mode.
In automatic mode the
M10
can be switched on via
R
LINK
control commands from the
P10
pre-amplifier,
via a trigger voltage on the 4-pin XLR socket, or by
the input signal.
See the section entitled “Main switch AUTO”.
VU meter
The purpose of the VU meter is to display and monitor
the modulation of the
M10
.
The following display modes are available:
1.) Momentary value
(fast)
In this mode the display immediately shows the momen-
tary output level.
2.) Average value
(slow)
In this mode the display shows the average output level
for the last three seconds.
3.) Average value with peak indicator
This display is a combination of the slow average display
plus the peak value for the last three seconds.
4.) VU meter off
In this mode the VU meter is switched off.
Содержание M 10
Страница 1: ...V 1 0 Bestell Nummer Order No 9103 0426 DE UK BETRIEBSANLEITUNG USER MANUAL M 10 ...
Страница 2: ...2 ...
Страница 6: ...6 Technische Übersicht ...
Страница 8: ...8 ...
Страница 9: ...9 Bedienung ...
Страница 14: ...14 ...
Страница 24: ...24 ...
Страница 25: ...25 English ...
Страница 28: ...28 Technical summary ...
Страница 30: ...30 ...
Страница 31: ...31 Operation ...
Страница 36: ...36 ...
Страница 46: ...46 ...
Страница 47: ...47 Anhang Appendix ...
Страница 52: ...52 ...
Страница 54: ... elektroakustik GmbH Co KG Herford Deutschland Germany ...