32
Front panel controls
Main switch
The switch positions have the following functions:
OFF
The unit is switched off.
ON
The unit is switched on.
AUTO
(Automatic power-on)
The
M10
features a universal automatic power-on circuit
which switches the unit on automatically from stand-by
mode. If you wish to use the automatic power-on circuit,
the main switch must be set to the “AUTO” position.
The automatic power-on circuit can be activated using
either an
R
LINK
control cable, a trigger voltage from the
pre-amplifier, or by the music signal itself.
Switching on using an R
LINK
control cable
If the
M10
is connected to the
P10
pre-amplifier with
an
R
LINK
lead, it is automatically switched on and off
together with the pre-amplifier.
Switching on using a trigger voltage
(4-pin XLR socket)
An alternative method of remotely switching on the
M10
is to use a trigger voltage (+5 V ... +20 V), which is
provided by many pre-amplifiers, such as the
P10
.
The trigger voltage is connected to the trigger control
input of the 4-pin XLR socket.
When the trigger voltage is switched off, the
M10
switches itself off after a delay of about one minute.
Note
For the
P10
/
M10
combination, the
accessory
range includes special 4-pin XLR cables with integral
trigger wire.
Switching on via the music signal
The
M10
also features a signal-controlled automatic
power-on circuit, which switches the
M10
on as soon as
a music signal is present at one of its inputs.
When the music signal ceases, the
M10
switches itself
off again after a delay of about thirty minutes. The power-
down delay ensures that the
M10
does not switch itself
off inadvertently in response to brief pauses in the music.
Note
Signal-controlled power-on is not recommended for the
M10
, as there is always a long delay between the music
signal’s appearance and the amplifier’s ready state
(loudspeaker switched on), due to the inevitable
preliminary heating time of the valves. For this reason
wherever possible we recommend switching the unit on
by
R
LINK
, by trigger voltage, or manually using the main
switch.
Caution!
The main switch is not an isolation switch. Parts of
the machine remain connected to mains voltage even
when the main switch is at the off position. The cur-
rent drain in stand-by mode and in automatic mode is
stated in the section entitled “Specification”.
If you know the amplifier will not be used for a long
period, we recommend that you withdraw the mains
plug to isolate it from the mains supply.
Содержание M 10
Страница 1: ...V 1 0 Bestell Nummer Order No 9103 0426 DE UK BETRIEBSANLEITUNG USER MANUAL M 10 ...
Страница 2: ...2 ...
Страница 6: ...6 Technische Übersicht ...
Страница 8: ...8 ...
Страница 9: ...9 Bedienung ...
Страница 14: ...14 ...
Страница 24: ...24 ...
Страница 25: ...25 English ...
Страница 28: ...28 Technical summary ...
Страница 30: ...30 ...
Страница 31: ...31 Operation ...
Страница 36: ...36 ...
Страница 46: ...46 ...
Страница 47: ...47 Anhang Appendix ...
Страница 52: ...52 ...
Страница 54: ... elektroakustik GmbH Co KG Herford Deutschland Germany ...