SerialGate User Guide
15
Serial Port:
RJ-45 socket for serial ports (RS-232 or Combo(RS-422/485))
Power connector
: for connection of DC9~30V adapter cable
Terminal Block and DC Adapter Jack connect different power at the sa
me time power is applied at the same time as it may cause irreparabl
e damage to the product, if you do not!
Terminal block power connector:
for connection of terminal block power cable
Reset button:
SerialGate reboots if this button is pressed for less than 3 seconds. If
pressed for longer than 3 seconds, SerialGate will restore its factory default settings.
LED:
Operation status of SerialGate. Next section describes the meaning of each LED
display status.
LAN port:
8-pin RJ45 jack connects SerialGate to networking devices such as Ethernet
card, hub, and router.
SG-1010/232, Combo LED / RESET
LED
Status
Meaning
PWR
(Red)
On
Power supplied to the device
Off
No power supplied to the device
LAN
(Green)
Off
No active network connection
On
Network activated
RDY
(Red)
Blink
Normal operation
On
System Booting
Off
System Error
RS-422
On
Serial port set to RS-422 mode (Combo model)
RS-485
On
Serial port set to RS-485 mode (Combo model)
Serial
Tx/Rx
Green Blink Serial data transmitted
Orange Blink Serial data received
LAN Port
(Right Orange)
On
Network connected
Off
Network disconnected
Blink
LAN data being transmitted